Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S07-156
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S07-156
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/11/2009 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/20/2009 RONALD BROWN ZONING HC SITE REVIEW Approved
03/24/2009 PETER MCLAUGHLIN LANDSCAPE REVIEW Approved
03/31/2009 FERNE RODRIGUEZ PIMA COUNTY WASTEWATER Approved March 27, 2009


To: Lorenzo Ortiz
Dowl Engineers

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

___________________________
From: Tom Porter, Sr. CEA (520-740-6719), representing the Pima County
Departments of Wastewater Management and Environment Quality

Subject: Old Vail Plaza, Old Vail Road at Houghton Road, Lots 1-18 & Common Area 'A'
Tent. Plat – 3rd Submittal
S07-156


The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the as submitted.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above-mentioned comments, please contact me.
03/31/2009 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: S07-156 Old Vail Plaza
10000 E. Old Vail Road
Tentative Plat/Development Plan Review

TRANSMITTAL DATE: March 30, 2009

DUE DATE: April 8, 2009

COMMENTS:

1. 1. The Zoning Review Section approves the tentative plat for this subdivision, subject to the following changes on the executed tentative plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised tentative plat to verify that those changes do not affect any zoning requirements.

2. The following two items are still outstanding and must be addressed.

a. The parking spaces north of the building on lot 14 must be provided with wheel stops.

b. Per your response the pedestrian circulation to the dumpsters are to be added during the CD's review. The plan cannot be approved until the circulation is provided. At this time there appears to be sufficient area around the west of the building on lot 13 and the east side of the building on lot 14 to provide the necessary sidewalks. If the sidewalks change due to building configuration or design changes the sidewalks can be addressed at the CD's stage.

C:\planning\cdrc\tentativeplat\S07156tp3.doc
04/01/2009 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


WR#189593 March 31, 2009


DOWL Engineers
Attn: Gregory Santoro
166 W Alameda
Tucson, AZ 85701

To Mr. Santoro :

SUBJECT: Old Vail Plaza- Resubmittal
S07-156


Tucson Electric Power Company has reviewed and approved the development plan submitted March 25, 2009 It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. The customer is responsible for the new trenching to relocate them as well as the relocation cost.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to:

Tucson Electric Power Company
Attn: Rich Harrington
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-918-8726

Please call the area Designer Warren McElyea at (520) 918-8268, should you have any questions.


Sincerely,



Henrietta Noriega
Office Specialist
Design/Build
hn
Enclosures
cc: City of Tucson, (Email only)
W. McElyea Tucson Electric Power
04/08/2009 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering and Floodplain Review, 04/08/2009,

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Old Vail Plaza
S07-156, T15S, R15E, SECTION 26

RECEIVED: Tentative Plat, Landscape Plan and Drainage Report on March 11, 2009

The subject submittal has been reviewed and it can not be approved at this time. Address the following comments before review can continue. Prepare a detailed response that explains the revisions that were made and references the exact location in the drainage report and on the Tentative Plat where the revisions were made:

Drainage Report:

1. Based on a recent field visit, the steep slope, on the north side of the property appear to be steeper than 2:1 (the slope appears to be closer to 1:1 in some areas). The slope appears to be unstable and shows evidence of erosion, scour and collapse in several areas, which might be an indication of the slope instability. This issue needs to be addressed satisfactorily in the geotechnical report and stability analysis may need to be performed at different locations along the slope. Additionally, the setbacks from this slope need to be determined based on how stable the slope is and/or on the proposed slope stabilization and protection methods.
2. Provide a proposed conditions table that shows the runoff reduction resulting from the proposed drainage scheme and retention basins. The runoff information on Drainage exhibit E-2 shall match the information in the required table.

Tentative Plat:

1. An approved DSMR is required to modify the substandard width for the P.A.A.L's leading to the water well site. Additionally, it is not clear how the P.A.A.L's are made part of Lot 17. Show clearly Lot 17 lot lines including bearings and dimensions and the proposed gates.
2. Based on a recent field visit, the steep slope, on the north side of the property appear to be steeper than 2:1 (the slope appears to be closer to 1:1 in some areas). The slope appears to be unstable and shows evidence of erosion, scour and collapse in several areas, which might be an indication of the slope instability. This issue needs to be addressed satisfactorily in the geotechnical report and stability analysis may need to be performed at different locations along the slope. Additionally, the setbacks from this slope need to be determined based on how stable the slope is and/or on the proposed slope stabilization method. Show clearly the proposed slope stability and protection methods and the proposed setback from the slope.
3. Please be advised that any proposed slope protection shall have the appropriate key-ins, which are based on the recommendation of the geotechnical report. Additionally, any part of the proposed slope protection proposed to be installed within the City of Tucson well site, will require COT Water permission.
4. Show on the plat all applicable building setbacks, including slope and ponding water setbacks, as required by (D.S. 2-03.2.4.M).
5. Based on a recent field visit, the topography does not look like the information shown on Detail E. Address this issue and revise as needed.
6. Keynote #36 is not clear. Will the screen wall be 5' high or will the entire wall (i.e. screen and retaining) be 5' high. Additionally, It seems that Screen Wall Standard Detail 109 should be referenced in Keynote #36.
7. Wheelchair ramps Details 7, 8, 9, 10 and 15 are not standard. Revise all wheelchair ramps details to match the standard detail and reference the applicable Standard Detail numbers. Modifying the standard wheelchair ramps requires and approved DSMR. Revise the wheelchair ramps on the grading plan.
8. Call out the retaining walls on Details F, G and H. Please be advised that retaining walls may require separate permits.
9. Provide additional spot elevations in the driveways and PAAL's centerlines.
10. Show, on all applicable details, steel reinforcement for all concrete ramps and spillways.
11. Reference Concrete Curb Terminal Section Standard Detail 212 on Detail 2 and revise the detail accordingly.
12. Provide a detail that shows the bleed pipes with the proposed 6" orifice openings at the inlet of all detention basins bleed pipes. The pipe inlet and outlet inverts and slopes shall be provided. Please be advised that the orifice shall be installed closer to the pipes inverts.
13. It appears that the sidewalk is blocked on one side of the ramp in Detail 15. Address this issue and revise as needed.
14. Revise the Tentative Plat in accordance with the drainage report revisions.



RESUBMITTAL REQUIRED: Revised Tentative Plat and Drainage Report
04/08/2009 ANDY STEUART COT NON-DSD REAL ESTATE Denied Comments provided by Andy Steuart, Property Agent, City Managers Office/Real Estate Program, (520) 837-6715


S07-156 Old Valil Plaza: Resubmittal - CDRC - Tentative Plat Review

-In reference to Dowl HKM, 3/10/09 Letter, Comment Responses, W.O. 3022.40342.01; Tucson Water does not agree to purchase Lot 17. Resolution 12993, adopted by Mayor and Council 12/17/84, arranged for the dedication of 7 wellsites to provide supplemental water to Rita Ranch. Tucson Water identifies Lot 17 as one of these seven wellsites to be dedicated, per Agreement (Exhibit A) Paragraph 7 of Resolution No. 12993. Request Tucson Water/New Development be contacted concerning conveyance of this wellsite prior submission of final plat.
-Concerning the ground elevation of Lot 17, General Notes, item 16., state "No grading beyond what is necessary for building sites...". In light of this, Tucson Water has requested the following; "The lot earthwork shall keep well site grade at an elevation equivalent to the average final grade of the adjacent surrounding parking lot paving. Any wall segments desired to be constructed by the developer prior to Water Department lot development, shall wrap-around at each corner, and plan details submitted to Tucson Water Plant Design Supervisor for structural, drainage, and aesthetic (block-matching) coordination."

-Concerning Public Water Easements, request public water easements (Keynotes 1., 2., 3. & 4. on Sht. 5/16) be called out with range and bearings.

-On Final Plat, Tucson Water requests a maintenance fee be waived for parking lots and drainage basins.

-On Final Plat, request dedication language be provided in Dedication block, as provided in City of Tucson Development Standard No. 2-03.0, Platting Procdures, paragraph 2-03.6.3. B.
04/16/2009 JOSE ORTIZ COT NON-DSD TRAFFIC Denied TDOT-Traffic cannot approve this project due to the numerous unresolved items with the coordination of this project with the Houghton Road improvements.

Items include:

- Final roadway layout and associated right of way requirements.
- PIA requirements versus in-lieu fees for Old Vail Road improvements.

An additional meeting is needed for coordination.
04/17/2009 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

April 17, 2009

Gregory D. Santoro, P.E.
DOWL Engineering
166 West Alameda
Tucson, Arizona 85701

Subject: S07-156 Old Vail Plaza Tentative Plat

Dear Gregory:

Your submittal of March 11, 2009 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and 5 sets of the DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

5 Copies Revised Tentative Plat (Real Estate, Traffic, Engineering, Zoning, DSD)

3 Copies Revised Landscape Plan (Engineering, Zoning, DSD)

2 Copies Drainage Report (Engineering, DSD)





Should you have any questions, please call me at 837-4919.