| 05/23/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 05/24/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Patricia Gehlen DATE: July 16, 2007 CDRC/Zoning Manager SUBJECT: Camino Seco Village, 8820 E. 21st Street Final Plat S05-211 (First Review) T14S, R15E, Section 15 RESUBMITTAL REQUIRED: Final Plat. The Final Plat (FP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Final Plat: 1. Please include a response letter to the comments along with the corrected copies of the FP. 2. Submit the Subdivision Improvement Assurances for review. The following items are required in the assurance package if a Third Party Trust Agreement will be used: · Special Warranty Deed · Trust Agreement · Amendment to Trust · Agreement to Construct Submit the above documents containing original signatures, copies of the documents and signatures will not be forwarded to the City of Tucson attorney for review. For information only. 3. The title block of the plat must match the Subdivision Assurances verbatim. For information only. 4. A legend, which shows and describes all symbols used on the drawing will be placed………..…per D.S. 2-03.6.1.L. Also include all abbreviations used on the drawing in the legend. 5. Add the following hold-harmless statement: "(I/We), the undersigned, do hold hereby hold harmles the City of Tucson ………". The statement shall be written verbatim per D.S. 2-03.6.3.B.3. 6. If applicable, the following BENIFICIARY block must be included on the title page………….….per D.S. 2-03.6.3.C. 7. Provide location, dimensions, areas, in square footage, and purposes of lots proposed for………...per D.S. 2-03.6.4.D. 8. Corner lots may be designated with a star symbol indicating………..…per D.S. 2-03.6.4.G. Show a star at the SE corner of lot 35. 9. At least one corner of the subdivision will be tied by course and distance to a section corner, a quarter section corner, or an established City or County survey monument per……………………….D.S. 2-03.6.5.C. 10. Indicate the manner of which the basis of bearing was used………..…per D.S. 2-03.6.5.C.1a, b or c. 11. Show the symbol on the legend for the standard monument detail 103 on the centerline of the proposed streets per D.S. 2-03.6.5.4. Where is the Brass Cap in conc. to be set used in the plat? 12. Show the distance and bearing between all monuments used. Indicate whether measured or calculated………per D.S. 2-03.6.5.5. 13. Please submit a copy of the subdivision boundary closure calculations. If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/8820 E. 21st Street FP |
| 06/06/2007 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Denied | SUBJECT: CAMINO SECO VILLAGE S05-211 Tucson Electric Power Company (TEP) has received the final plat submitted for review May 23, 2007. TEP is unable to approve the plat at this time. On April 4, 2007 TEP requested the following additional plans in order to complete the electrical design. The design is necessary to determine our easement requirements and review the final plat. Additional plans necessary for preparation of the design are: building plans including water, electrical, landscape, sidewalk and paving plans. Also, submit the AutoCAD version of the plat on a CD or email to lcastillo@tep.com <mailto:lcastillo@tep.com> . The AutoCAD should be in the following format: A. Complete and identical to the official hard copy (paper) subdivision plat. B. DWG format C. AutoCAD Version 2002 or lower D. 2D, not 3D E. Layers relate to a unique set of CAD features within the drawing. (For example all lot lines should be on one layer, street centerlines another layer) F. Required Layers: Lot Line, Right of Way, and Street Centerline G. At least three tie points are required; one must be a Section or a Quarter and the others may be street intersections or lot corners. Bearings and distances must be designated from the tie points H. Any special fonts, X-REFs, or attachments should be submitted along with the CAD drawing. Please contact me at (520) 917-8745 if you have any questions. Liza Castillo, Right of Way Agent Land Management Tucson Electric Power Co. Unisource Energy Gas & Unisource Energy Electric PH: (520) 917-8745 RightFax: (520) 545-1416 lcastillo@tep.com <mailto:lcastillo@tep.com> |
| 06/06/2007 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approved | June 6, 2007 TO: Rick Murillo, P.E. Stantec Consulting THRU: Patricia Gehlen, CDRC Manager City of Tucson, Development Services Department FROM: Tom Porter, Sr. CEA Development Review Division (Wastewater) Pima County Development Services Department SUBJECT: Camino Seco Village, Lots 1-35 and Common Areas A-C Final Plat – 1st Submittal S05-211 The proposed sewer collection lines to serve the above-referenced development have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ), and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. The Pima County Department of Environmental Quality and the Wastewater Management Department hereby approve the above referenced submittal of the Tentative Plat as received by us on February 08, 2007. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality Department. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating, or engaging in any activity which may cause or contribute to air pollution. If you have any questions regarding the above comments, please do not hesitate to contact me. Sincerely, Tom Porter Telephone: (520) 740-6579 Copy: Project File |
| 06/14/2007 | TERRY STEVENS | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: S05-211 Camino Seco Village Final Plat TRANSMITTAL: 06/14/07 DUE DATE: 06/21/07 COMMENTS: 1. The Zoning Review Section approves the final plat for this subdivision. Should there be any changes requested by other CDRC members, however, the Zoning Review Section approval is void, and we request copies of those changes to insure that those changes do not affect zoning requirements. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 C:\planning\cdrc\finalplat\S05-211 fpa.doc |
| 06/14/2007 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S05-211 CAMINO SECO VILLAGE/FINAL PLAT DATE: 6/14/07 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: 1.) Label approved interior street name. Use the suffix of Loop. es |
| 06/19/2007 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | >>> Andy Steuart 06/19/2007 10:41 AM >>> S05-211 Camino Seco Village: Final Plat Review - No comment. |
| 06/19/2007 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Gary Ault, Mapping Supervisor Pima County Assessor's Office Mapping Department DATE: June 19, 2007 RE: Assessor's Review and Comments Regarding Final Plat S05-211 CAMINO SECO VILLAGE T141515 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor's Office requirements. _______ Plat does not meet Assessor's Office requirements. COMMENTS: THANK YOU FOR YOUR SUBMITTAL. IF YOU HAVE ANY QUESTIONS PLEASE CALL ROSANNA WERNER AT 740-4390 NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED. ROSANNA WERNER |
| 06/22/2007 | PGEHLEN1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Passed | |
| 07/16/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES July 16, 2007 Richard Murillo Stantec Consulting, Inc. 201 North Bonita Avenue, Suite 101 Tucson, Arizona 85745 Subject: S05-211 Camino Seco Village Lots 1-35 Final Plat Dear Richard: Your submittal of May 23, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 4 Copies Revised Final Plat (Engineering, TEP, Addressing, DSD) Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 750-7470 fpresubmittal |