Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S05-211
Parcel: Unknown

Address:
8820 E 21ST ST

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW

Plan Number - S05-211
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/17/2007 PAUL MACHADO ENGINEERING REVIEW Approved
01/19/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

January 19, 2007

Rick Murillo, P.E.
Stantec Consulting
201 North Bonita Avenue, Suite 101
Tucson, Arizona 85745

Subject: S05-211 Camino Seco Village Lot 1-35 Tentative Plat

Dear Rick:

Your submittal of December 4, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Tentative Plat (Wastewater, Landscape, DSD)

2 Copies Revised Landscape and NPPO Plans (Landscape, DSD)

A WRITTEN REQUEST FOR AN EXTENTION TO THE TENTATIVE PLAT REVIEW PERIOD MUST BE SUBMITTED TO AND GRANTED BY THE CDRC OFFICE PRIOR TO RESUBMITTAL OF THESE PLANS.

Should you have any questions, please call me at 791-5608, ext 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 750-7470
12/01/2006 MARILYN KALTHOFF START PLANS SUBMITTED Completed
12/15/2006 JOE LINVILLE LANDSCAPE REVIEW Denied 1) The native plant preservation plan calculations on NO.01 are incorrect. The minimum preservation values are incorrect for several of the species and they do not correspond with the value for "minimum TOS". We also recommend that row 5 of the calculation table on that page be designated as "proposed transplant on site", rather than "Total Plants On Site". DS 2-15 Worksheet

2) Landscape and irrigation installation in right-of-way areas must be approved and permitted by the City Engineer. The plans must comply with the City Engineer's requirements on construction, irrigation, location, and plant type. Provide verification, in writing, of any approvals obtained.

The irrigation system may not be located within the right-of-way or under streets without City Engineer approval, a seperate water meter may be required. See drawing I0.08 (Irr. line under Street A).

Show the irrigation lines on I2.04 (sheet 8 of 15).


RESUBMITTAL OF ALL REVISED PLANS IS REQUIRED.
12/22/2006 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
12/22/2006 TERRY STEVENS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: S05-211
Camino Seco Village
Tentative Plat

TRANSMITTAL: 12/22/06

DUE DATE: 01/02/07

COMMENTS:


1. The Zoning Review Section approves the tentative plat for this subdivision, subject to the following changes on the executed tentative plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised tentative plat to verify that those changes do not affect any zoning requirements.

2. In the lot setback requirements on page 1 of 4 add a note stating that front loading garages setback will be a minimum of 18' from property line or 19' back of sidewalk, which ever is greater.

3. Provide the following at time of Final Plat. Three (3) copies of Covenants, Conditions, and Restrictions (CC&Rs) are required when there is to be an association of home owners to assume responsibility for the ownership and maintenance of commonly-owned property.

If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000.


TLS C:\planning\cdrc\tentativeplat\S05-211-3tpca.doc
12/27/2006 FRODRIG2 PIMA COUNTY WASTEWATER Denied December 27, 2006

TO: Richard S. Murillo, P.E.
Stantec Consulting

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: R S Engineering (Contract Reviewer)
Chandubhai Patel, P.E.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Camino Seco Village
Lots 1 – 35 and Common Areas A -C
Tentative Plat – 3rd Submittal
S05-211

The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

Sheet 1: The Location Map is misleading in that Halcyon Acres Annex No. 2. Lots 72 and 73 appear to be shaded. Please adjust the Location Map.

Sheet 1: Book 9, M&P Page 69 is the plat number for South Lawn Memorial Park. Please correct the Title with the correct M & P book and page for Halcyon Acres Annex No. 2.

Sheet 2: The on-site sewers are public, located in public streets. Revise General Notes #28 so that Private Sewers are omitted from the list of Homeowner’s Association responsibilities.

Sheet 3: MH. #3, appears to be a terminal manhole with an INV. IN, we are not sure from which direction, and there is no proposed reach of sewer as a means for servicing Lot #1, as shown on the plan.. Revise the plan so that it shows an extension of the proposed sewer that will front Lot 1 and correct the sewer Line and MH tables as appropriate. Or, explain the omission of sewer service to Lot 1.

The next submittal of this project will be the 4th submittal. A check for the review fee of this submittal in the amount of $78.00 per sheet, made out to PIMA COUNTY TREASURER must accompany the revised set of blue lines and response letter.

For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly.


If you have any questions regarding the above mentioned comments, please contact me.

Sincerely,



Michael J. Harrington, Sr. CEA
Telephone: (520) 740-6579

Copy: RSE Job #0432.07.1