Plan Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - FINAL PLAT REVIEW
Plan Number - S03-021
Review Name: RESUBMITTAL - FINAL PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/28/2004 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 06/29/2004 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approv-Cond | SUBJECT: Civano II S03-021, T15S, R15E, SECTION 12 RECEIVED: Final Plat and Assurances on June 28, 2004 The subject submittal has been reviewed. We offer the following comments: Final Plat: The Final Plat is acceptable and shall be recommended for conditional approval pertaining to Engineering and Floodplain, subject to the following: 1. The approval of the Tentative Plat. 2. Show on the Final Plat Mylar the recordation information for all proposed easement dedications by a separate instrument. CC & R's: The CC & R's are acceptable pertaining to Engineering and Floodplain. Assurances: 1. Revised Assurances shall be submitted with the Final Plat Mylar. 2. The Common Areas must be described in the Assurances exactly as they are on the Final Plat (i.e. Common Area 'A' (open space) etc.). 3. Provide a Copy of the Trust Agreement (Not to be recorded). 4. Exhibit "A" is missing. RESUBMITTAL REQUIRED: Final Plat Mylar and Assurances |
| 07/06/2004 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S03-021 CIVANO II / REVISED FINAL PLAT DATE: JULY 6, 2004 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: 1: Change Zinc Street to Courtland Drive. This should be one Street Name. |
| 07/06/2004 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: S03-021 CIVANO II, LOTS 1-192/REVISED FINAL PLAT DATE: 7/22/04 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. NOTE: Approved on condition that “Courtland Drive” is one street and “Painted Turtle Loop” is corrected to “Painted Turtle Lane” on mylar. ***The Pima County Addressing Section can use digital CAD drawing files when submitted with your final plat Mylar. These CAD files can be submitted through the Pima County Subdivision Coordinator. The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.*** |
| 07/14/2004 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | Key Notes #14 and #21: Real Estate is currently waiting for legal descriptions for the trail easement and drainage easement and current title reports specific to the trail and drainage easements to be provided by the applicant. Key Note #13: Contact Pima County for grant of Sewer Easement. |
| 07/14/2004 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approved | July 14, 2004 TO: Pattie Davis, MMLA, Inc. THRU: FROM: ____________________________________ representing the Pima County Departments of Wastewater Management and Environmental Quality SUBJECT: Civano II, Lots 1-192, Blocks 1 & 2 and Common Areas A-D - Submittal S03-021 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. SHEETS 1 & 6. Show the recording information for the sewer easement. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the final plat. The required revision(s) may be shown on the Mylars. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you wish to discuss the above comments, please contact me at the phone number provided above, under my signature. |
| 07/14/2004 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Approved | No objection |
| 07/19/2004 | MICHAEL ST. PAUL | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Plans Coordination Office Development Services Department PROJECT: S03-021 Civano II Final Plat FROM: Michael St.Paul Planning Technician FOR: Patricia Gehlen Principal Planner Zoning Review Section Development Services Department TRANSMITTAL: July 19, 2004 DUE DATE: July 12, 2004 COMMENTS CODE SECTION/ DEVELOPMENT STANDARD The Zoning Review Section approves the final plat for this subdivision, subject to the following changes on the executed final plat. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised final plat to verify that those changes do not affect any zoning requirements. 1. Provide the recording information for the easement of the public access trail along Mesquite Wash. 2. Add the letter "e" to the word "are" in seventh line of number 26, Exhibit B. 3. Please provide the executed final plat for the Development Services Department Director's signature and a memo stating that the members of the CDRC have approved the final plat. When these items are received, along with forty-four half-sized copies of the plat, the final plat will be scheduled for consideration at the next available Mayor and Council meeting. If you have any questions about this transmittal, please call Michael St.Paul at (520) 791-5608. |
| 07/22/2004 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | TEP is completing electrical layout plan. Contact Lisa Castillo for addidtional information. |
| 07/22/2004 | CRAIG GROSS | ZONING-DECISION LETTER | REVIEW | Completed | |
| 07/22/2004 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: CIVANO II Lots 1-193 S03-021 Tucson Electric Power Company (TEP) has reviewed the final plat dated June 16, 2004. TEP is unable to approve the plat at this time. The preliminary electrical design for the subject subdivision will be mailed today. Please review this design and contact this office by August 12, 2004 with any conflicts or desired changes. Your written approval of this design is necessary for a final construction drawing. Any changes requested after we have received your written approval will be billable. In order for this Company to approve the final plat, the following will be required. For those lots that do not have a 10' Public Utility Easement strip in front of the lots, a 6' x 6' easement is required at each of the pedestal locations. (Sheet 7) Delete the word FOR from the third paragraph of the dedication to read as: "......ALL EASEMENTS AS SHOWN HEREON FOR THE PURPOSES OF ACCESS, INSTALLATION AND MAINTENANCE OF PUBLIC SEWERS AND UTILITIES............" A copy of the preliminary design has been forwarded to Southwest Gas. Please insure utility coordination by providing a copy of this preliminary design to Qwest and the Cable Company. Show all requested requirements on the resubmittal of the final plat. Submit two bluelines to the City of Tucson for TEP's final approval. Liza Castillo Land Management Tucson Electric Power Company lcastillo@tep.com Office: (520) 917-8479 Cell Phone/Pager: (520) 904-2668 Fax: (520) 917-8400 |
| 07/22/2004 | LIZA CASTILLO | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: CIVANO II Lots 1-192 S03-021 The Final Plat dated August 4, 2004 for the subject project will meet this Company's easement requirements. Please forward any resubmittals of the final plat to this office. Electric service will be provided to this subdivision in accordance with the rules and regulations approved by the Arizona Corporation Commission. Please contact me at (520) 917-8479 if you have any questions. Liza Castillo Land Management Tucson Electric Power Company lcastillo@tep.com Office: (520) 917-8479 Cell Phone/Pager: (520) 904-2668 Fax: (520) 917-8400 |