Plan Number: S03-021
Parcel: Unknown

Address:
10411 E BILBY RD

Review Status: Completed

Review Details: RESUBMITTAL - TENTATIVE PLAT REVIEW

Plan Number - S03-021
Review Name: RESUBMITTAL - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/04/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed Engineering submittal contains Mesquite Ranch Wash WASH submittal but no drainage report.
06/08/2004 JOE LINVILLE LANDSCAPE REVIEW Denied 1) This development is subject to the provisions of the scenic corridor zone. A separate review and approval is required. TCC 23A-42

2) Development in proximity to the Mesquite Ranch Wash is subject to the provisions of TCC Chapter 29, Article VIII.
Approval of the Wash Ordinance Mitigation Plan is required.
06/09/2004 LAITH ALSHAMI ENGINEERING REVIEW Denied SUBJECT: Civano II
S03-021, T15S, R15E, SECTION 12

RECEIVED: Tentative Plat, Landscape Plan, and Mitigation Plan & Report on June 04, 2004

The subject submittal has been reviewed. The Tentative Plat and the Drainage Report can not be recommended for approval until the Mitigation Report is approved.

The Mitigation Plan and Report are not recommended for approval for the following reasons:

Engineering Comments:

Address the depth of the proposed sewer line and clarify if the line will be installed below the scour depth or not. If the line is proposed to be installed above the scour depth, how will it be protected from scour.

Please be advised that the Floodplain Use Permit fee will be $150.00 for the first submittal and $300.00 for subsequent submittals (if required).

Landscape Comments:

I have reviewed the documents and have concluded that the report does not include sufficient evidence to justify the resource area delineation along the entire length of the wash. Per TCC 29-16(a) an acceptable delineation would channel and banks of a wash, and those portions of the study area containing vegetative resources and wildlife habitat areas. In order to establish this delineation an inventory of the existing vegetation and wildlife habitats within the study area would be required.

The tentative plat includes a proposed trail access easement which overlays portions of the study area. General note 49 on sheet 1 of the tentative plat proposes that the actual trail location be determined in the future in cooperation with Parks and Recreation and Development Services. Staff from both departments has evaluated the site and has determined that there is high potential for the trail to be located within portions of the study area without alteration to the existing vegetation while providing an important open space corridor. The proposal is compatible with the purpose and intent of the regulations. Recommendation for approval is contingent upon clarification of the resource area boundary.

Prepare a detailed response that explains the revisions that were made and references the exact location in the drainage report and on the Development Plan where the revisions were made.

If I can be of any further assistance, you may reach me at 791-5550, Ext. 1195, or you can email me at Laith.Alshami@tucsonaz.gov

RESUBMITTAL REQUIRED: WASH Ordinance Mitigation Report
06/10/2004 MICHAEL ST. PAUL ZONING REVIEW Approved
06/22/2004 CRAIG GROSS CDRC STAFF TRACKING Completed
06/22/2004 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: June 22, 2004

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks, Parks and Recreation

SUBJECT: CDRC Transmittal, S03-021Civano II: Resubmittal TP

CC: Craig Gross, Development Services


Staff has reviewed and approved.


Please feel free to call me at 791-4873 x 215 if you have any questions.