Plan Number: S03-021
Parcel: Unknown

Address:
10411 E BILBY RD

Review Status: Completed

Review Details: REVISN TENT PLAT & CORE RESUB

Plan Number - S03-021
Review Name: REVISN TENT PLAT & CORE RESUB
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/05/2009 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/10/2009 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207


AUDREY FARENGA
ADDRESSING REVIEW
PH #: 740-6800
FAX #: 623-5411


TO: CITY PLANNING
FROM: AUDREY FARENGA, ADDRESSING REVIEW
SUBJECT: S03-021 CIVANO II/TENTATIVE PLAT REV. 1
DATE: 11/05/09



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.


***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through Pima
County Addressing. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
11/10/2009 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied PLANNING AND DEVELOPMENT SERVICES

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S03-021 Civano II: Revision 11/10/09

(ü) Tentative Plat
( ) Development Plan
(ü) Revised Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other

CROSS REFERENCE: C9-91-14, S97-035

NEIGHBORHOOD PLAN: Civano PAD, Revised Civano Master Plan, MOU, and Impact Systems Standards

GATEWAY/SCENIC ROUTE: Houghton Road (scenic)

COMMENTS DUE BY: November 18, 2009

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
( ) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies With Plan Policies
(ü) See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
( ) Resubmittal Required


REVIEWER: J Beall 791-5550 DATE: 11/10/09

Comments


1) Section C-4.c.ii, of the Civano PAD calls out that each Mini Park shall be at least 4,500 square feet. Please provide the total square footage for each Mini Park. Please provide this information as a note on Sheet 2, Sierra Morado Unit 1 Miniparks - Layout Plan, under the Layout Notes.

2) Section C-4.c.ii, of the Civano PAD, also requires that all parks will be irrigated with reclaimed water. Please show this on the landscape/irrigation plans, and include as a note on Sheet 8, Sierra Morado Unit 1 Miniparks - Specifications. Also include the following language as a note under the Landscape Notes section:

"All parks will be irrigated with reclaimed water and will incorporate water harvesting features, native vegetation, and recycled or low environmental impact building materials. Additionally, the Sierra Morado Declaration of Covenants, Conditions and restrictions, recorded at Docket 12420, Page 1235, Official Records, Pima County, Arizona (as may be amended from time to time) shall provide for sustainable park maintenance that minimizes or eliminates the use of pesticides, herbicides, chemical fertilizers, and fossil fuel-burning machinery."
11/17/2009 LAITH ALSHAMI ENGINEERING REVIEW Approved Laith Alshami, Engineering and Floodplain Review, 11/17/2009,

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Civano II
S03-021, T15S, R15E, SECTION 12

RECEIVED: Revised Tentative Plat on November 03, 2009

The subject submittal has been reviewed. The revised Tentative Plat is acceptable and it is recommended for approval pertaining to Engineering and Floodplain.

Based on the proposed revisions to the Tentative Plat, an as-built Grading Plan must be submitted for review and approval.
11/18/2009 JOE LINVILLE LANDSCAPE REVIEW Approved
11/18/2009 MICHAEL ST. PAUL ZONING REVIEW Denied CDRC TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
S03-021
Civano II
Pulte Home: Revision #1 Tentative Plat.

Due Date: November 18, 2009


FOR: Patricia Gehlen, CDRC Manager

TRANSMITTAL: November 18, 2009


COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.


1) Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is November 3, 2010.

2) Provide dimensions for both the lots that are being converted to common areas for the mini parks and the width of the pathway between each of these lots. Depict the mini parks as a continuation of Common Area C. Demonstrate on the tentative plat that each mini park meet the minimum square footage requirement of four thousand five hundred (4500) square feet (C-3 Definitions [p.56] & C-4.c.ii., Functional Open Space Areas [p.62] Civano Master Pad).

3) Please see additional information relative to the mini parks provided by John Beall.
11/19/2009 JOHN WILLIAMS ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

November 19, 2009

Warren Thompson
Stantec Consulting
201 N. Bonita Avenue #101
Tucson, Arizona 85745

Subject: S03-021 Civano II Tentative Plat

Dear Warren:

Your submittal of November 3, 2009 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a set of 3 DETAILED cover letters explaining how each outstanding requirement has been addressed:

ALL BLACKLINES MUST BE FOLDED

3 Copies Revised Tentative Plat (Community Planning, Zoning, PDSD)

3 Copies Revised Landscape Plan (Community Planning, Zoning, PDSD)

Should you have any questions, please call me at 837-4919.


Sincerely,





John Williams
Planning Technician

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: (520) 750-7470