Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: S03-014
Parcel: Unknown

Address:
131 W ELVIRA RD

Review Status: Completed

Review Details: RESUBMITTAL - FINAL PLAT REVIEW

Plan Number - S03-014
Review Name: RESUBMITTAL - FINAL PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/10/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
02/11/2004 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: S03-014 DESERT VISTA/REVISED FINAL PLAT
DATE: February 11, 2004



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

NOTE: ON FINAL MYLAR:

1.) Change “Tucson Nogales Hwy.” to Nogales Highway on Location Plan.



***The Pima County Addressing Section can use digital CAD drawing files when
submitted with your final plat Mylar. These CAD files can be submitted through the Pima
County Subdivision Coordinator. The digital CAD drawing files expedite the addressing
and permitting processes when we are able to insert this digital data into the County’s
Geographic Information System. Your support is greatly appreciated.***
02/26/2004 ELIZABETH EBERBACH ENGINEERING REVIEW Denied TO: Craig Gross, CDRC
SUBJECT: Desert Vista
REVIEWER: Doug Williams
DATE: 24 February 2004
ACTIVITY NUMBER: S03-014
T15S, R13E, Sections 13

Resubmittals Required: Revised Final Plat, Assurances, and Survey closure calculations

SUMMARY: Engineering Division has reviewed the Final Plat, Subdivision Assurance package and perimeter closure calculations. Approval is not recommended at this time. The following comments must be addressed prior to resubmittal:

Final Plat:

1. Ensure the name, type, and width of all easements within the subdivision boundary being created by this plat are indicated properly and label each as public or private, along with the appropriate dedication notation. Please omit the second paragraph under the word "DEDICATION" on sheet 1, if the street and drainage easement are to be private (DS 2-03.6.3 B 2 & Sec.2-03.6.4 A).
2. Depict and label a continuous No Vehicular Access Easement (NVAE) as deemed appropriate, on the east perimeters of Lots 1-9, adjacent to Missiondale Road (DS 2-03.6.4 H).
3. Re-check the survey closure calculations and revise the curve data table entries accordingly. The curve table provided on sheet 2 does not match the closure report provided. Specifically, point numbers 170, 102 and 169 arc lengths and deltas do not correspond with the data provided in the table (DS 2-03.6.5).
4. Include specific descriptions of each Common Area (retention/detention basin for A, and private street or streets for B) in the Title Block on both sheets of the plat.
5. Ensure all tract boundary lines; easements, and other rights-of-way; and property lines of residential units, and common areas, with accurate dimensions, bearings, or deflection angles and radii, arcs and central angles of all curves are indicated and labeled properly (DS Sec.2-03.6.5.B&C).
6. Provide a distance for the dimensioning indicated between the project boundary and 100-year floodplain limit on Missiondale Road.

Assurance Package:

1. Provide special warranty deed to accompany the assurance package.
2. Provide a copy of the Trust Agreement (Trust # 3610).
3. Revise all applicable sheets in the assurance package to reflect the changes that must be made in the Title Block subdivision description language described above (sheet 1 in the Trust Amendment, and Sheet 1 and Exhibit A (legal description) in the Third Party Trust Agreement To Construct Subdivision Improvements. The Title Block description and these sheets must match one another exactly.

Resubmittal will require a revised Final Plat, boundary survey closure calculations and a complete subdivision assurance package, addressing all of the comments provided above. The final plat cannot be scheduled for Mayor and Council consideration until the assurances are approved by the City Engineer's Office (DS 2-03.7.1G). All sections of the assurance documentation must match word-for-word for the descriptions of the common areas listed on the Final Plat pages. Review all documents and check to see that the verbiage for the subdivision description matches the Final Plat. For example, the letter and use for each common area description shall match the Final Plat descriptions and letters. This must be correct in order to prevent delay of the assurance review in the City of Tucson's legal offices.

If you have any questions, I can be reached at 791-5550, extension 1189 or Dwillia1@ci.tucson.az.us.

Douglas Williams
Sr. Engineering Associate
Engineering Division
Development Services Department
02/26/2004 ELIZABETH EBERBACH ENGINEERING REVIEW Denied TO: Craig Gross, CDRC
SUBJECT: Desert Vista
REVIEWER: Doug Williams
DATE: 24 February 2004
ACTIVITY NUMBER: S03-014
T15S, R13E, Sections 13

Resubmittals Required: Revised Final Plat, Assurances, and Survey closure calculations

SUMMARY: Engineering Division has reviewed the Final Plat, Subdivision Assurance package and perimeter closure calculations. Approval is not recommended at this time. The following comments must be addressed prior to resubmittal:

Final Plat:

1. Ensure the name, type, and width of all easements within the subdivision boundary being created by this plat are indicated properly and label each as public or private, along with the appropriate dedication notation. Please omit the second paragraph under the word "DEDICATION" on sheet 1, if the street and drainage easement are to be private (DS 2-03.6.3 B 2 & Sec.2-03.6.4 A).
2. Depict and label a continuous No Vehicular Access Easement (NVAE) as deemed appropriate, on the east perimeters of Lots 1-9, adjacent to Missiondale Road (DS 2-03.6.4 H).
3. Re-check the survey closure calculations and revise the curve data table entries accordingly. The curve table provided on sheet 2 does not match the closure report provided. Specifically, point numbers 170, 102 and 169 arc lengths and deltas do not correspond with the data provided in the table (DS 2-03.6.5).
4. Include specific descriptions of each Common Area (retention/detention basin for A, and private street or streets for B) in the Title Block on both sheets of the plat.
5. Ensure all tract boundary lines; easements, and other rights-of-way; and property lines of residential units, and common areas, with accurate dimensions, bearings, or deflection angles and radii, arcs and central angles of all curves are indicated and labeled properly (DS Sec.2-03.6.5.B&C).
6. Provide a distance for the dimensioning indicated between the project boundary and 100-year floodplain limit on Missiondale Road.

Assurance Package:

1. Provide special warranty deed to accompany the assurance package.
2. Provide a copy of the Trust Agreement (Trust # 3610).
3. Revise all applicable sheets in the assurance package to reflect the changes that must be made in the Title Block subdivision description language described above (sheet 1 in the Trust Amendment, and Sheet 1 and Exhibit A (legal description) in the Third Party Trust Agreement To Construct Subdivision Improvements. The Title Block description and these sheets must match one another exactly.

Resubmittal will require a revised Final Plat, boundary survey closure calculations and a complete subdivision assurance package, addressing all of the comments provided above. The final plat cannot be scheduled for Mayor and Council consideration until the assurances are approved by the City Engineer's Office (DS 2-03.7.1G). All sections of the assurance documentation must match word-for-word for the descriptions of the common areas listed on the Final Plat pages. Review all documents and check to see that the verbiage for the subdivision description matches the Final Plat. For example, the letter and use for each common area description shall match the Final Plat descriptions and letters. This must be correct in order to prevent delay of the assurance review in the City of Tucson's legal offices.

If you have any questions, I can be reached at 791-5550, extension 1189 or Dwillia1@ci.tucson.az.us.

Douglas Williams
Sr. Engineering Associate
Engineering Division
Development Services Department