Plan Number: S03-009
Parcel: Unknown

Review Status: Completed

Review Details: RESUBMITTAL - TENTATIVE PLAT REVIEW

Plan Number - S03-009
Review Name: RESUBMITTAL - TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/30/2003 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
07/02/2003 JIM EGAN COT NON-DSD FIRE Approved The Tentative Plat is approved 07/02/03.
07/09/2003 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied COMPREHENSIVE PLANNING TASK FORCE COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

S03-009 Rancho Del Este II 07/08/03

(X) Tentative Plat
() Development Plan
(X) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-02-26

NEIGHBORHOOD PLAN: Pantano East Area Plan

GATEWAY/SCENIC ROUTE: Gateway: Golf Links Road

COMMENTS DUE BY: July 14, 2003

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
(X) See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(X) Resubmittal Required:
(X) Tentative Plat
() Development Plan
(X) Landscape Plan
() Other

REVIEWER: JBeall 791-4505 DATE: 7-8-03

Comprehensive Planning Task Force Comments
Rancho Del Este II, S03-009



The applicant’s request to rezone the property located at the northeast corner of Golf Links Road and Bonanza Avenue that was approved by Mayor and Council is subject to meeting certain rezoning conditions. It should be noted that these comments are for Rancho Del Este II. It appears from the tentative plat that this project has a new name, “Rancho Paraiso”.


Although the tentative plat shows the provision of vehicular and pedestrian connectivity to the vacant parcel to the east (as required by rezoning condition no. 7), it is not clear if Common Area “C” will be a stubbed out street with sidewalks or a landscaped common area. Also, the landscape plan appears to indicate that there is a sidewalk along this area that abuts Aztec Point Trail. Please show on the landscape plan how Common Area “C” will be integrated into the development as a stubbed out street, while it is being held for future vehicular/pedestrian connectivity. This needs to be recognized as a future street connection by adjacent home buyers. (Rezoning condition no. 4).

3. The tentative plat does not show that all units along the western and southern property lines (lots 163-183 and 75-90), as well as units along the northern property line adjacent to Arizona La Victoria (lots 24-26 and 153-162), shall be limited to one story. Please add a note to the General Notes section and/or on the tentative plat - it is not redundant – rather it indicates compliance with this rezoning condition. (Rezoning condition no. 8).
07/10/2003 LAITH ALSHAMI ENGINEERING REVIEW Denied SUBJECT: Rancho Paraiso
S03-009, T14S, R15E, SECTION 23

RECEIVED: Tentative Plat, Landscape Plan and Drainage Report on June 30, 2003

The subject project has been reviewed. The Landscape Plan is acceptable for Engineering and Floodplain Purposes.
The Drainage Report and the Tentative Plat shall be recommended for approval once the following comments have been addressed satisfactorily. Please be advised that the response letter should be detailed with references to how and where the comments were addressed in the report and/or the plan, in order to facilitate and expedite the resubmittal review. We offer the following comments:

Drainage Report:

1. The Eastview Wash is classified as a Xeroriparian Intermediate Habitat, which is protected under the provisions on Chapter 26 "Floodplain and Erosion Hazard Management" of the City Code. The City's Policy concerning protected Riparian Habitat Washes is to apply the WASH Ordinance mitigation requirements if the protected wash has defined banks. If the wash has no defined channel, it is treated as an ERZ Wash for mitigation purposes. Address this issue and provide the appropriate mitigation report. A response letter from McGann and associates was not found in the submittal.
2. Depict on the drainage exhibits Eastview Wash top of banks or the revise 100-year floodplain and delineate the resource areas.
3. The discharge velocities at culverts 1, 2 and 3 are high and erosive. Address this issue and the need for erosion control structures at the outlets. Analyze Box Culvert 1 existing conditions and compare to post development conditions. The design and analysis for the required erosion control structures.
4. Investigate the possibility of providing water harvesting within all the common areas.
5. It appears that based on the shown side slopes and water depths, detention/retention basins 2C and 2A/B require security barriers based the information on page 82 of the "Stormwater Detention/Retention Manual". Address this issue and revise as necessary.
6. Submit with the Grading Plan a Geotechnical Report, which addresses the stability of the proposed slopes (i.e. the need for slope stabilization) and the proposed retention basin percolation rate.

Tentative Plat:

1. The submitted differential grading justification is acceptable for Groups 2, 3 and 4. However, it is not acceptable for Group 1. The stated detention/retention basin water surface elevation and the grade break elevation across from lots 3 and 4 are not consistent with the elevations shown on the Tentative Plat. It appears that the pad elevations for lots 3 through 4 can be lowered. For future reference, please be advised that the presence of drainage swales or rills within a parcel, has no bearing on the determination if the proposed grades meet the differential grading requirements.
2. Show security barriers around the proposed detention/retention basins, which require them.
3. Revise the Tentative Plat according to the Drainage Report revisions.


RESUBMITTAL REQUIRED: Revised Tentative Plat, Drainage Report
07/11/2003 GLENN HICKS COT NON-DSD PARKS & RECREATION Denied DATE: July 11, 2003

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks, Parks and Recreation

SUBJECT: CDRC Transmittal, Project S03-009 Rancho Paraiso: Tentative Plat Review

CC: Craig Gross, Development Services


Denied. Public trail easement not shown.

Please feel free to call me at 791-4873 x 215 if you have any questions.
07/14/2003 DAN CASTRO ZONING REVIEW Approved
07/15/2003 TIM ROWE PIMA COUNTY WASTEWATER Needs Review
07/15/2003 DALE KELCH COT NON-DSD TRAFFIC Denied Traffic Engineering REJECTS this T.P.

1. Add general note to sheet 1 to read "All non-signalized intersection street names must have E-W block number addresses for E-w roadways and N-S block number addresses for N-S roadways."

Note to the consultant: This note is DOT policy now. It arose from problems with contractors installing street signs using county vice city standards. Adding this note does not require you to add any street sign details. TDOT is in the process of having this note added to the DS T.P. checklist.

D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dkelch1@ci.tucson.az.us
07/17/2003 JOE LINVILLE LANDSCAPE REVIEW Approved