Permit Number: DS19-16
Parcel: 11708223A

Address:
902 S 6TH AV

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS19-16
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/18/2019 SBEASLE1 START PLANS SUBMITTED Completed
09/25/2019 STEVE SHIELDS ZONING REVIEW Approved
09/30/2019 SBEASLE1 ENV SVCS REVIEW Reqs Change Environmental & General Services has completed our review of the Technical Standards Modification Request for The Flash South property located at 902 S. 6th Avenue in Tucson.

The proposal is to provide two 4 cubic yard containers for storage of refuse and recycling materials. The containers will be located in an enclosure located on the west-central portion of the property. The building occupant will roll the containers out to Russell Avenue on the west side of the property for servicing.

Detail A3/6 on Sheet 6 shows a section through the waste enclosure. On the north and south sides of the enclosure, a six foot high concrete block wall is proposed. On the west side of the enclosure, a sliding gate almost six feet high will be installed, On the east side of the enclosure, a three foot high concrete block wall is proposed. The three foot high block wall on the east side of the enclosure will not completely screen the waste containers from persons on The Flash property.

Please have the applicant explain why the east wall is only three feet high and does not screen the entire height of the waste containers. Explain why this wall is not the same height as the north and south block walls.

Thanks and let me know if there are any questions concerning this review.

Tom Ryan, P. E.
City of Tucson
Environmental & General Services Department
Thomas.Ryan@TucsonAZ.gov
(520) 837-3713, office
10/07/2019 JOHN VAN WINKLE ENGINEERING REVIEW Approv-Cond 1) Engineering has no objection to the use of a Standard Driveway apron for access off of 6th Av
2) Refer to Environmental services for comments regarding request for relief from TS 8-01.5.2 and TS 8-01.5.3
10/08/2019 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Reqs Change TSMR RETURNED FOR MORE INFORMATION (per Environmental Services reviewer's comments)- A resubmittal is required

Permit/Activity Number: DS19-16
(Related to Permit: DP17-0249)
Project Description: TSMR, Flash South: Driveway - TSM 10-01.4.0. Trash Enclosure - TS 8-01.5.2 and TS 8-01.5.3.

Fees Due: $676.50 (see the image below).
Note: We require payment prior to accepting a resubmittal.
Please pay:
1. Online
2. In person at the permit counter (Mon-Fri, 8:00 AM to 2:00 PM)
3. By mail - a check payable to City of Tucson, address is shown below, include the Activity Number

Online Payments (Visa, MC, Discover, American Express)
https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. Total fees due: Payment portal may take 1-2 days to update to the correct total
2. Not case-sensitive but a hyphen is needed, e.g.: dp19-0000
3. Enter your Permit Nbr. and click the “Continue” tab
4. If any issues, try using the browser Internet Explorer.

To view the review comments: www.tucsonaz.gov/PRO, enter Activity Number.
(If information isn't shown yet, check back later as data uploads to PRO periodically.)
Submit the following items to the PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, please include the Activity Number.
1) Any documents requested by review staff

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, First Floor
Tucson, AZ 85701