Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS10-18
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/10/2010 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 12/14/2010 | DAVE MANN | FIRE | REVIEW | Approved | |
| 12/14/2010 | RONALD BROWN | ZONING HC | REVIEW | Approved | |
| 12/15/2010 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DSMR-10-18 831 E Limberlost Drive S10-027 - Limberlost Estates Subdivision (FLD) Development Standard Modification Request Transmittal date: December 15, 2010 COMMENTS: Zoning Conditionally Approves DSMR request 1. DS 3-05.2.4.A.1 approved to a maximum distance of 170 feet to the farthest unit from the visitor parking lot area. 2. DS 3-01 Figure 1 - street cross section approved as depicted on subdivision plat drawing 36-foot width. 3. DS 2-08.5.1.A - The four-foot width of the sidewalk behind the wedge curb is approved as depicted on the street cross section drawing. 4. DS 3-01.10 Figure 1- Wedge curb approved for the driveway areas only. 5. 9-06.2.5.B.2 - conditionally approved. Approval by Landscaping is required. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 12/16/2010 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 12/17/2010 | MPADILL1 | COMMUNITY PLANNING | REVIEW | Approved | PLANNING & DEVELOPMENT SERVICES DEPARTMENT (PLANNING COMMENTS) Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS10-18 831 E. Limberlost Drive () Tentative Plat () Development Plan () Landscape Plan () Revised Plan/Plat (X) Other - Site Plan CROSS REFERENCE: S10-027 Limberlost Estates FLD AREA/NEIGHBORHOOD PLAN: Northside Area Plan GATEWAY/SCENIC ROUTE: NO COMMENTS DUE BY 12/17/10 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () DSMR Proposal Complies with Plan Policies () See Additional Comments Attached (X) No Additional Comments - Complies With Planning Comments Submitted on: REVIEWER: msp 837-6971 DATE: 12/15/10 No objection by Plan policies, on the following modifications to Development Standards: 1. DS3-05.2.4.A.1 - Proposed distance of parking spaces from each dwelling unit 2. DS3-01 fig.1 - To provide Five (5) feet six (6) inch wide sidewalks, narrowest at four (4) feet wide where sidewalk crosses each dwelling unit driveway. 3. DS9-062.5.B.2 - Tree removal mitigated by planting new trees of equal amount or above, at appropriate (detention basin) location |
| 12/17/2010 | MATT FLICK | ENGINEERING | REVIEW | Approved | |
| 12/20/2010 | FRODRIG2 | ENV SVCS | REVIEW | Approved | Date Case Number Project Address December 20, 2010 DS10-018 Limberlost Estates 831 E. Limberlost Drive DEVELOPMENT PLAN Comments: The proposed Development Plan for the Limberlost Estates, Case No. DS10-018, Located at 831 E. Limberlost Drive, meets the minimum requirements for the Environmental Services, Solid Waste Disposal and Recycle Requirements Standard 6-01.0 and is here Approved. Environmental Services Department Development Plan Review Reviewer: Tony Teran Office Phone (520) 837-3706 E-mail: Tony.Teran @tucsonaz.gov |
| 12/20/2010 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | |
| 12/22/2010 | JOHN WILLIAMS | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE PLANNING & DEVELOPMENT SERVICES 12/22/2010 Antony C. Tsang A.C. Tsang Engineering Group, Inc. 4626 E. Fort Lowell Road Suite S Tucson, Arizona 85712 Re: DSMR DS10-18, 831 E. Limberlost Drive (S10-027) Request: DS 3-05.2.4.A.1 - Modify the development standard to exceed the visitor parking past the maximum one hundred fifty (150) feet of the front or street side yard property lines of each residential unit. DS 3-01 Figure 1 - Modify the development standard to reduce the width of cross section from 40 feet to 36 feet with 6 inch vertical curbs and 5 ½ feet sidewalks on each side. DS 3-01.4.1.A.1.a - Modify the development standard to reduce the sidewalks to four (4) feet behind the wedge curb as depicted on the street cross section drawing. DS 3-01.10 Figure 1 - Modify the development standard to allow a wedge curb adjacent to the sidewalk at driveway. DS 9-06.2.5.B.2 - Modify the development standard to allow the removal of some riparian habitat (trees) to construct a drainage channel. The Development Standard Modification Request (DSMR) for DS 3-05.2.4.A.1 listed above has been APPROVED with the following conditions: 1. Maximum distance of 170 feet to the farthest unit from the visitor parking lot area. The Development Standard Modification Request (DSMR) for DS 3-01 Figure 1 listed above has been APPROVED with the following conditions: 1. Street cross section approved as depicted on subdivision plat drawing 36 foot width. The Development Standard Modification Request (DSMR) for DS 3-01.4.1.A.1.a listed above has been APPROVED with the following conditions: 1. The four foot width of the sidewalk behind the wedge curb is approved as depicted on the street cross section drawing. The Development Standard Modification Request (DSMR) for DS 3-01.10 Figure 1 listed above has been APPROVED with the following conditions: 1. Wedge curb approved for the driveway areas only. The Development Standard Modification Request (DSMR) for DS 9-06.2.5.B.2 listed above has been APPROVED with the following conditions: 1. None PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE PLAN IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 837-4893. Sincerely, John Williams Planning Technician Planning & Development Services Department Attachments: 1 XC: File Records Fax (520) 325-0979 |