Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS08-24
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/06/2008 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 06/09/2008 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 06/09/2008 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | |
| 06/10/2008 | DAVE MANN | FIRE | REVIEW | Approved | |
| 06/10/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Passed | |
| 06/13/2008 | MATT FLICK | ENGINEERING | REVIEW | Approved | DSD Engineering has no objection or adverse comment to approval of a DSMR to Dev. Std. 2-08.4.1.F to allow a sidewalk between a parking space and the PAAL serving that space. |
| 06/18/2008 | ANDY VERA | ENV SVCS | REVIEW | Approv-Cond | ES has no objections to the request for relief from DS 2-08.4.1 1. However, upon review of the DP there is not adequate enclosures to support solid waste collection services. It is recommended that four single enclosures or two double wide enclosures be provided for this development to suport both refuse and recycle waste streams of these 9 buildings. 2. Enclosure detail must annotate and/or show that the gates are equipped with the ability to be secured in the open and closed positions. Specifically the closed position to prevent accidental closing during service operation. DS 6-01.4.2.C.4. If any question you may contact Andy Vera at (520) 791-5543 ext.1212 or e-mail: Andy.Vera@tucsonaz.gov |
| 06/20/2008 | FRODRIG2 | COMMUNITY PLANNING | REVIEW | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS08-24 8668 E. Tanque Verde Roadad ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment ( ) Other Site Plan CROSS REFERENCE: SE-07-008 & D06-0011 NEIGHBORHOOD PLAN: General Plan GATEWAY/SCENIC ROUTE: COMMENTS DUE BY 06/4/08 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () Proposal Complies with Annexation or Rezoning Conditions (XXXX) Proposal in Substantial Compliance with Plan Policies () See Additional Comments Attached REVIEWER: drcorral 791-4505 DATE: 06/4/08 |
| 06/23/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES June 23, 2008 Brian Payne, E.I.T. DOWL Engineers 166 West Alameda Tucson, Arizona 85701 Re: DSMR 08-24- 8668 East Tanque Verde Road (D06-0011/D08-0029) Request: DS 2-08.4.1.F- Modify the Development Standards to allow the pedestrian circulation system to be placed between a parking space in a garage and the PAAL that provides access as shown on the plan. The Development Standard Modification Request (DSMR) listed above has been APPROVED by the CRDC committee with the following conditions: 1) Andy Vera with Environmental Services has comments concerning the solid waste collection. The comments maybe found on-line. PLEASE NOTE THAT A GENERAL NOTE MUST BE ADDED TO THE DEVELOPMENT PLAN WHICH STATES THE DSMR CASE NUMBER, DATE OF APPROVAL, MODIFICATIONS GRANTED, AND CONDITIONS IMPOSED. IN ADDITION, THE CASE NUMBER MUST BE ADDED TO EACH SHEET OF THE DEVELOPMENT PLAN, LANDSCAPE PLAN, AND NPPO PLAN, IN THE LOWER RIGHT CORNER NEAR THE TITLE BLOCK. If you have any additional questions, please contact me at 837-4919. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records Fax (520) 624-0384 |