Permit Number: DS07-42
Parcel: 133033000

Review Status: Completed

Review Details: DEV STDS MODIFICATION REVIEW

Permit Number - DS07-42
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/03/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
10/04/2007 JOSE ORTIZ TRAFFIC TRAFFIC Approved Traffic has no objections to the proposed modifications to the solid waste containers.
10/05/2007 JIM EGAN FIRE REVIEW Approved
10/10/2007 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

FROM: David Rivera
Principal Planner
DSD Zoning Review Section

PROJECT: DSMR-07-42
9855 E. Speedway Blvd.
Tanque Verde Valley Casitas
Development Standard Modification Request

Transmittal date: October 10, 2007

COMMENTS: Approved with conditions

1. Zoning supports the DSMR if Environmental Services Department finds the proposed method acceptable and if the screening methods where applicable are met.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
10/11/2007 ANDY VERA ENV SVCS REVIEW Denied 1. Each in ground container site must comply with screening requirements per DS 6-01.2.2.A & 6-01.2.4.2.
A. Will require rear and side wall protection with a minimum 10 ft x 10 ft inside clear service area between the bollards and the fron gates. DS 6-01.4.1.B. & 6-01.4..2.C.2.
B. Gates must be equipped with the ability to be secured in the open and closed positions. DS 6-01.4.2.C.4.

2. Provide refuse/recycle enclosure detail.

3. Access and approach to refuse collection sites okay. Maneuverability within development works.

Please correct on resubmittal.
10/11/2007 MATT FLICK ENGINEERING REVIEW Approv-Cond DSD Conditionally Approves the DSMR to Dev. Std. 6-01 to allow the placement of in-ground waste containers. The approval is conditional upon acceptance by Environmental Services of the maneuverability for waste collection vehicles.
10/12/2007 FRODRIG2 COMMUNITY PLANNING REVIEW Denied DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Development Standards Modification Request (DSMR)

CASE NUMBER: CASE NAME: DATE SENT

DS07-42 9855 E. Speedway 10/11/07

() Tentative Plat
(xxxxx) Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE:

NEIGHBORHOOD PLAN: Pantano East Area Plan

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 10/10/2007


SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
(XXXX) See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
( ) No Resubmittal Required:
() Tentative Plat
( ) Development Plan
() Landscape Plan
() Other

REVIEWER: drcorral 791-4505 DATE: 10/10/07
The General Plan together with the Design Guidelines provide direction for this request. The and the

General Plan
Policy 5: Promote Neighorhood identity and visual character
Supporting Policy 5.3.A Review and revise, as necessary, the City’s Design Compatibility Report requirements to assure the following key features continue to be addressed:
other site and architectural design considerations as outlined in policies and the Design Guidelines Manual/

Design Guidelines
B. Community Character and Design
3. Buffering/Screening/ Landscape Design

f. Landscape Screens (I.B.3.f)

Intent - Use landscape, grading, and walls to screen less visually attractive uses.

Related Policy Link - CCD Policy 6

Solution - Screen dumpster areas, outside storage, utility, and other free-standing equipment and water pumping stations by integrating them with the design and materials of the principal structure. Use a minimum six-foot-high masonry wall and two or more of the following:
Sound absorbent/sound scattering wall facing material such as tile, stone, or brick
Earth berms
Dense planting up to six-foot high


Conclusion:

Based on General Plan and Design Guidelines the deletion of the walls cannot be supported. However, a reduction in wall height, to 4 feet with appropriate vegetative screening is recommended.
10/12/2007 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Denied COMMUNITY DESIGN REVIEW COMMITTEE
CITY OF TUCSON - DEVELOPMENT SERVICES

October 12, 2007

John A. Holley
The WLB Group
4444 East Broadway Blvd.
Tucson, Arizona 85711

Re: DSMR 07- 42- 9855 East Speedway Boulevard (D07-0041)

Request: DS 6-01 - Replace Walls and Bollards of dumpster enclosure with structure shown in the attached detail.

The Development Standard Modification Request (DSMR) listed above has been Denied by the CRDC committee per the on-line comments.









If you have any additional questions, please contact me at 837-4919.

Sincerely,


Patricia Gehlen
Zoning/CDRC Manager
Development Services Department

Attachments: 1
XC: file
Records