Permit Review Detail
Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS07-42
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/03/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 10/04/2007 | JOSE ORTIZ | TRAFFIC | TRAFFIC | Approved | Traffic has no objections to the proposed modifications to the solid waste containers. |
| 10/05/2007 | JIM EGAN | FIRE | REVIEW | Approved | |
| 10/10/2007 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DSMR-07-42 9855 E. Speedway Blvd. Tanque Verde Valley Casitas Development Standard Modification Request Transmittal date: October 10, 2007 COMMENTS: Approved with conditions 1. Zoning supports the DSMR if Environmental Services Department finds the proposed method acceptable and if the screening methods where applicable are met. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 10/11/2007 | ANDY VERA | ENV SVCS | REVIEW | Denied | 1. Each in ground container site must comply with screening requirements per DS 6-01.2.2.A & 6-01.2.4.2. A. Will require rear and side wall protection with a minimum 10 ft x 10 ft inside clear service area between the bollards and the fron gates. DS 6-01.4.1.B. & 6-01.4..2.C.2. B. Gates must be equipped with the ability to be secured in the open and closed positions. DS 6-01.4.2.C.4. 2. Provide refuse/recycle enclosure detail. 3. Access and approach to refuse collection sites okay. Maneuverability within development works. Please correct on resubmittal. |
| 10/11/2007 | MATT FLICK | ENGINEERING | REVIEW | Approv-Cond | DSD Conditionally Approves the DSMR to Dev. Std. 6-01 to allow the placement of in-ground waste containers. The approval is conditional upon acceptance by Environmental Services of the maneuverability for waste collection vehicles. |
| 10/12/2007 | FRODRIG2 | COMMUNITY PLANNING | REVIEW | Denied | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Development Standards Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS07-42 9855 E. Speedway 10/11/07 () Tentative Plat (xxxxx) Development Plan () Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: NEIGHBORHOOD PLAN: Pantano East Area Plan GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: 10/10/2007 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies (XXXX) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: ( ) No Resubmittal Required: () Tentative Plat ( ) Development Plan () Landscape Plan () Other REVIEWER: drcorral 791-4505 DATE: 10/10/07 The General Plan together with the Design Guidelines provide direction for this request. The and the General Plan Policy 5: Promote Neighorhood identity and visual character Supporting Policy 5.3.A Review and revise, as necessary, the City’s Design Compatibility Report requirements to assure the following key features continue to be addressed: other site and architectural design considerations as outlined in policies and the Design Guidelines Manual/ Design Guidelines B. Community Character and Design 3. Buffering/Screening/ Landscape Design f. Landscape Screens (I.B.3.f) Intent - Use landscape, grading, and walls to screen less visually attractive uses. Related Policy Link - CCD Policy 6 Solution - Screen dumpster areas, outside storage, utility, and other free-standing equipment and water pumping stations by integrating them with the design and materials of the principal structure. Use a minimum six-foot-high masonry wall and two or more of the following: Sound absorbent/sound scattering wall facing material such as tile, stone, or brick Earth berms Dense planting up to six-foot high Conclusion: Based on General Plan and Design Guidelines the deletion of the walls cannot be supported. However, a reduction in wall height, to 4 feet with appropriate vegetative screening is recommended. |
| 10/12/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Denied | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES October 12, 2007 John A. Holley The WLB Group 4444 East Broadway Blvd. Tucson, Arizona 85711 Re: DSMR 07- 42- 9855 East Speedway Boulevard (D07-0041) Request: DS 6-01 - Replace Walls and Bollards of dumpster enclosure with structure shown in the attached detail. The Development Standard Modification Request (DSMR) listed above has been Denied by the CRDC committee per the on-line comments. If you have any additional questions, please contact me at 837-4919. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records Fax (520) 881-7492 |