Review Status: Completed
Review Details: DEV STDS MODIFICATION REVIEW
Permit Number - DS06-40
Review Name: DEV STDS MODIFICATION REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/15/2006 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 09/18/2006 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: David Rivera Principal Planner DSD Zoning Review Section PROJECT: DSMR-06-40 10901 e Drexel Road Sierra Morado Unit 4 Development Standard Modification Request Transmittal date: September 18, 2006 COMMENTS: Approved with conditions 1. Zoning approves the DSMR pending approval by Engineering. 2. Phased grading should be reviewed by the Landscape Review Section to ensure compliance with any Landscape and NPPO requirements. I do not believe that the Landscape Section has an opportunity to review the proposed grading. 3. The Phasing lines must be depicted and labeled on the grading plans and if necessary on the landscape and possibly the NPPO plans. Contact Joseph Linville Landscape review supervisor for more information. |
| 09/20/2006 | JCLARK3 | ENV SVCS | REVIEW | Approved | Request is for grading the site at one time. |
| 09/22/2006 | DALE KELCH | TRAFFIC | TRAFFIC | Approved | Traffic Engineering has no objection to DS06-40 10901 E. Drexel Road (S06-031) Sierra Morado Unit 4 Phase 2 (modification request to Development Standard 11-01.2.1.C) Jose Ortiz, P.E. Engineering Project Manager Department of Transportation (520) 791-4259 Ext 305 Fax (520) 791-5526 email: jose.ortiz@tucsonaz.gov |
| 09/25/2006 | MKALTHO1 | COMMUNITY PLANNING | REVIEW | Approv-Cond | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Development Standard Modification Request (DSMR) CASE NUMBER: CASE NAME: DATE SENT DS06-40 10901 E. Drexel Road 09/25/06 ( X ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment ( ) Other - Site Plan CROSS REFERENCE: S06-031 Sierra Morado, Unit 4 - Phase 2 NEIGHBORHOOD PLAN: Civano PAD 12 GATEWAY/SCENIC ROUTE: COMMENTS DUE BY September 25, 2006 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) Proposal Complies with Annexation or Rezoning Conditions ( X ) Proposal in Substantial Compliance with Plan Policies ( X ) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: ( X ) No Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: JBeall 791-4505 DATE: 9/25/06 Development Standards 11-01.2.0 PERMITS REQUIRED 2.1 Permits C. Grading permits may be issued for single or multiple building sites, not to exceed 35 acres per permit. Although the proposed request to modify Development Standard 11-01.2.1.C is not in conflict with the plan policies of the Civano PAD, staff is concerned that by grading the site at one time instead of by phases could have a negative impact on the existing development. However, given there appears to be no conflict, this request should provide possible solutions to mitigate any negative impacts that could occur if Sierra Morado Unit 4 - Phase 2 takes an unusually long time for build out. The one time grading could leave a large swath of exposed dirt and debris that might compromise the Civano experience. |
| 09/25/2006 | JIM EGAN | FIRE | REVIEW | Approved | |
| 09/26/2006 | MATT FLICK | ENGINEERING | REVIEW | Approved | No objection to granting the DSMR to Dev. Std. 11-01.2.1.C to allow grading more than 35 acres at one time. |
| 10/06/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE CITY OF TUCSON - DEVELOPMENT SERVICES October 6, 2006 Karl Ryan Pulte Development Corporation 6893 North Oracle Road, Suite 121 Tucson, Arizona 85704 Re: DSMR 06-40 - 10901 E. Drexel Road (S06-031) Request: DS 11-01.2.1.C - Allow for an area greater than 35 acres to be graded at one time. The Development Standard Modification Request (DSMR) listed above has been Approved by the CRDC committee with the following conditions: 1) If the tentative plat is to be phased, the grading will have to match the phase lines on the tentative plat, 2) Compliance with DS 11-01.2.3 will be required. If you have any additional questions, please contact me at 791-5608. Sincerely, Patricia Gehlen Zoning/CDRC Manager Development Services Department Attachments: 1 XC: file Records |