Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP22-0242
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/29/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 09/09/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Reid Park Zoo – Sloth Exhibit Development Package (1st Review) DP22-0242 TRANSMITTAL DATE: September 9, 2022 DUE DATE: September 16, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is August 23, 2023. 2-06.2.0 APPLICATION SUBMITTAL REQUIREMENTS 1. COMMENT: 2-06.2.2 – Remove sheets 2 & 3 from the DP and provide any required information on a new sheet. 2. COMMENT: 2-06.2.4 – The development package is designed to allow for concurrent review of any site related reviews. Remove all building/electrical code sheets from the DP as they will not be reviewed at this time. 2-06.3.0 FORMAT REQUIREMENTS 3. COMMENT: 2-06.3.12 – Once comments 1 & 2 have been addressed revise the drawing index. CONTENT REQUIREMENTS 4. COMMENT: 2-06.4.2.D - Once comments 1 & 2 have been addressed revise the page number and the total number of pages on each sheet. 5. COMMENT: 2-06.4.3 – Provide the development package case number, DP22-0242 , adjacent to the title block on all sheets. 6. COMMENT: 2-06.4.4 - The project-location map to be located on the first sheet of the development package in the upper right corner, shall cover approximately one square mile, be drawn at a minimum scale of three-inch equals one mile. 7. COMMENT: 2-06.4.4.C – Label the section corners; north arrow, and the scale on the location map. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 8. COMMENT: 2-06.4.7.A.6.a – As 22nd St is designated as an Arterial on the COT MS&R Map provide a general note stating “THIS PROJECT IS DESIGNED TO MEET THE OVERLAY ZONE(S) CRITERIA, UDC ARTICLE 5.4 MAJOR STREETS AND ROUTES SETBACK ZONE (MS&R)”. If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov. To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 09/14/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 09/19/2022 | SBLOOD1 | ENGINEERING | REVIEW | Approved | |
| 09/20/2022 | JVINCEN1 | FIRE | REVIEW | Approved | |
| 09/26/2022 | AWARNER1 | LANDSCAPE | REVIEW | Approved | |
| 09/28/2022 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | email from: COTDSDPermits To: Robert Just cc: Howard Dutt 09/28/2022 REVIEW NOTICE Returned for Corrections: DP22-0242 Site/Grading - Reid Park Zoo - Sloth Exhibit. New animal exhibit building with exterior animal holding. 3400 E ZOO CT FEE BALANCE: $ 1,899.07 ONLINE PAYMENTS ** If the online amount doesn't match "Fee Balance" above, check again in a few hours ** https://www.tucsonaz.gov/pdsd/fees 1- Click on: Pay Planning & Permit Fees 2- Enter Permit Nbr, example: dp20-0000 (not case-sensitive but a hyphen-dash- is needed) 3- Business/Individual Name: Leave this blank 4- "Continue" 5- In the Pay column - check the boxes YOUR NEXT STEPS 1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on the blue tab - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW 2. Title your SECOND submittal documents accordingly, example: 2_Comment Response Letter 3. UPLOAD documents to Filedrop: - Comment Response Letter (your response to REQUIRES CHANGE comments) - Plan Set (all pages, full set, even if no changes were made) - Documents requested by review staff FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp - "Existing Application" - "Permit Number" field: enter the number (and any notes for our staff) Sharon Beasley, Certified Permit Specialist City of Tucson, Planning & Development Services Dept. Email: COTDSDpermits@TucsonAz.gov (for development packages, land splits, Thursday Presubmittal meetings) Email: PDSDinquiries@TucsonAz.gov (for building permits) |