Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: DP22-0174
Parcel: 110036110

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP22-0174
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/25/2022 SBEASLE1 START PLANS SUBMITTED Completed
07/25/2022 SBEASLE1 ENGINEERING REVIEW Approved Approved by Loren Makus during the OK to Submit.
07/25/2022 SBEASLE1 ZONING REVIEW Reqs Change (The comments below are from the OK to Submit)

DP22-0174

1. Update the sheet index to reflect the correct number of pages in this new plan set.

2. Include the new DP number in the bottom right hand corner - DP22-0174.

3. Include the detail page that demonstrates the design of the proposed bicycle parking.

4. Demonstrate the storage shed is meeting the minimum setback requirement to the northern property line. The minimum setback requirements for a nonresidential use adjacent to a nonresidential zone is 1.5 times the height of the proposed building wall (UDC Table 6.3-4.A). As the storage shed's wall is 8' high, the minimum setback from the exterior shed wall to the property line is 12'.

Loran Shamis
Loran.Shamis@TucsonAz.gov
08/01/2022 AWARNER1 LANDSCAPE REVIEW Approv-Cond Protect adjacent existing trees from damage during construction/installation of shed.
08/08/2022 JPEELDA1 FIRE REVIEW Approved
08/19/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Tri Miller
08/19/2022

REVIEW NOTICE

Returned for Corrections: DP22-0174
Site - Puente Nuevo Plaza. Addition of a 7 x 15 foot shed.
3915 E FORT LOWELL RD

FEE BALANCE: $ 429.00
Please pay at a minimum, the REVIEW category fees.
A payment is required before your next submittal.

ONLINE PAYMENTS
** If the online amount doesn't match "Fee Balance" shown above, check back in a few hours **
https://www.tucsonaz.gov/pdsd/fees
1- Click on: Pay Planning & Permit Fees
2- Enter Permit Nbr, example: dp20-0000
(not case-sensitive but a hyphen-dash- is needed)
3- Business/Individual Name: Leave this field blank
4- "Continue"
5- In the Pay column - check the boxes
6- "Continue"

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. Title your SECOND submittal documents accordingly, example: 2_Comment Response Letter

3. UPLOAD A RESUBMITTAL to Filedrop:
- Comment Response Letter (your response to REQUIRES CHANGE comments)
- Plan Set (all pages, full set, even if no changes were made)
- Any other documents requested by review staff

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- "Existing Application"
- "Permit Number" field: enter the number (and any notes for our staff)
- Select "PLANS" for all documents


Sharon Beasley, Certified Permit Technician

City of Tucson, Planning & Development Services Dept.
Email: COTDSDpermits@TucsonAz.gov
(for development packages, land splits, Thursday Presubmittal meetings)
Email: PDSDinquiries@TucsonAz.gov
(for building permits)