Permit Number: DP21-0314
Parcel: 137060950

Address:
5401 S 12TH AV

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP21-0314
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/05/2022 JPEELDA1 FIRE REVIEW Approved
01/06/2022 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: Cindy Hogan
Thu 1/6/2022 4:23 PM

REVIEW NOTICE
Returned for Corrections: DP21-0314

DESCRIPTION: Site - Watermill Express. Kiosk replacement.
5401 S 12TH AV

Fee Balance: $0 (zero) Thank you for the payment.

YOUR NEXT STEPS
1. SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab to see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

2. UPLOAD A RESUBMITTAL and include:
1) Comment Response Letter (your response to REQUIRES CHANGE comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your SECOND submittal documents according to this example: 2_Comment Response Letter

FILEDROP for your Resubmittal
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- Select "Existing Application"
- In the "Permit Number" field, enter the number and, if applicable, any notes for our staff


Thank you.
Sharon Beasley, Building Permit Specialist

City of Tucson, Planning and Development Services
Email: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)
12/06/2021 SBEASLE1 START PLANS SUBMITTED Completed
12/20/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Watermill Express
Development Package (1st Review)
DP21-0314

TRANSMITTAL DATE: December 20, 2021

DUE DATE: December 21, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is November 21, 2022.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0314, adjacent to the title block on all sheets.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

2. COMMENT: 2-06.4.7.A.4 – Under “PROPOSED USES” you list “SUBJECT TO C-1: 4.9.13.O” This site is not zoned C-1 and Per UDC TABLE 4.8-4: PERMITTED USES - COMMERCIAL AND MIXED-USE ZONES, C-2 Zone there are no Use Specific Standards that apply.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

3. COMMENT: 2-06.4.9.H.5 – As separation is required from the vehicle use area to the short-term bicycle parking, see comment 5 below, provide a PAAL width dimension from the proposed short-term bicycle parking location west to the edge of PAAL.

4. COMMENT: 2-06.4.9.H.5.a – The wheel stop location dimension is not correct, see UDC Article 7.4.6.H.3.

5. COMMENT: 2-06.4.9.H.5.d – Per UDC Article 7.4.9.B.1.g Vehicular Use Areas. Short- and long-term bicycle parking are permitted in vehicular use areas provided the parking area is separated from vehicular parking and drive areas by a barrier or is located a sufficient distance from vehicular uses areas to prevent damage to the parked bicycles. Demonstrate how this requirement is met for the proposed short-term bicycle parking location.

6. COMMENT: 2-06.4.9.O – Per UDC Article 11.4.6 definition of Established Area Setback, when a street is designated on the COT MS&R Map the site is consider Developing Area for street setback requirements. Also, per a Zoning Administrator’s determination when a site borders on more than one street and one of the streets is designated on the COT MS&R map all streets are considered developing area for setback purposes. That all said, the “STREET – EST. AREA 20’-0”” shown under “PERIMETER YARDS” is not correct and should be listed as 21’ or Height, greater of the two, as measured from the outside edge of the nearest adjacent travel lane.

7. COMMENT: 2-06.4.9.R – Clearly demonstrate on the plan how access is provided from the accessible access aisle to the raised sidewalk.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
12/21/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed