Permit Review Detail
Review Status: Completed
Review Details: TENTATIVE PLAT REVIEW
Permit Number - DP21-0313
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/05/2022 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 04/20/2022 | SAMUEL ROGERS | ZONING | REVIEW | Approved | |
| 04/27/2022 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 05/10/2022 | AWARNER1 | LANDSCAPE | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/Native Plant Preservation Section PROJECT: Sunshine DTA ACTIVITY NO: DP21-0313 2nd submittal Address: 402 W Medina St Zoning: R-1 Existing Use: vacant, graded Proposed Use: Adult Day Care, Commercial Services Group TRANSMITTAL DATE: May 10, 2022 DUE DATE: May 2, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed. This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting. 1. This comment was not addressed - Please label the existing right of way for Medina Rd UDC 7.6.4.C.2.a. 2. Provide a detail to show tree planting with root barrier adjacent to walkways. 3. Provide a maintenance schedule for the landscape and irrigation for this project. UDC 2-10-4.2.A.4., please be specific. 4. Unless a Board of Adjustment is approved, a waiver of the Commercial Rain Water Harvesting plan is not possible. Demonstrate maximizing water harvesting. 5. This comment was not adequately addressed - Grading, hydrology, and landscape plans must be integrated to make maximum use of site storm water runoff for supplemental on-site irrigation purposes. The landscape plan or water harvesting plan shall indicate use of all runoff, from individual catch basins around single trees to basins accepting flow from an entire vehicular use area or roof area. UDC 7.6.6.C.2. The landscape, water harvesting, and grading plans must match. 6. Identify curb inlets/splash pads to landscape areas on water harvesting or landscape plans. Technical Standards 4-01.3.C.3. 7. Indicate basin inlets/outlets on both landscape and water harvesting plans. Provide spot elevations. Technical Standards 4-01.3.C.3. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package YOUR NEXT STEPS: Submit documents to the Filedrop https://docs.tucsonaz.gov/Forms/tucsonpermitapp Select "Existing Application" 1) Comment Response Letter (your response to the reviewer's Requires changes comments) 2) Plan Set (or individual sheets) 3) Any other items requested by review staff If you have any questions, please contact me at anne.warner@tucsonaz.gov |
| 05/24/2022 | JPEELDA1 | FIRE | REVIEW | Approved | |
| 06/24/2022 | SBEASLE1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Approved | Email from: Nicholas Jordan <Nicholas.Jordan@pima.gov> on behalf of Addressing <Addressing@pima.gov> To: CDRC Thu 6/23/2022 1:25 PM Pima County Addressing approves DP21-313 Sunshine, 2nd Submittal Review. Thank you Nicholas Jordan Site Review Project Manager - Addressing Official Pima County Development Services Department |
| 07/05/2022 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | 1. Show how First Flush Rentention is being obtained with exhibit/discussion. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 07/06/2022 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change |