Permit Number: DP21-0246
Parcel: 132131200

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP21-0246
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/27/2021 SBEASLE1 START PLANS SUBMITTED Completed
09/27/2021 SBEASLE1 OTHER AGENCIES PIMA ASSN OF GOVTS Passed
09/27/2021 SBEASLE1 UTILITIES SOUTHWEST GAS Passed
09/27/2021 SBEASLE1 OTHER AGENCIES U. S. POST OFFICE Passed
10/11/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Wendy’s at the Bridges
Development Package (1st Review)
DP21-0246

TRANSMITTAL DATE: October 7, 2021

DUE DATE: October 14, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is September 13, 2021.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0246, adjacent to the title block on all sheets.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

2. COMMENT: 2-06.4.9.R - The accessible signs are shown in the middle of the sidewalk on both the plan and detail, demonstrate on the plan that a 4’-0” sidewalk is maintained. Based on the 4’-0” dimension shown on the detail the post encroaches into the required 4’.

3. COMMENT: 2-06.4.9.R – Demonstrate on the plan that a 4’-0” clear sidewalk is maintained between what appears to a railing and the building.

4. COMMENT: Provide a copy of the Design Review Committee approval letter with the next submittal, see PAD-15 Section C.6.

If you have any questions about this transmittal, please contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov.

To resubmit your plans for additional review, please visit: https://docs.tucsonaz.gov/Forms/tucsonpermitapp

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
10/14/2021 AWARNER1 LANDSCAPE REVIEW Reqs Change CDRC TRANSMITTAL
TO: Planning and Development Services Department, Plans Coordination
FROM: Anne Warner, PLA
PDSD Landscape/Native Plant Preservation Section

PROJECT: Wendy’s Fast Food
ACTIVITY NO: DP21-0246
Address: 3434 S Kino Pkwy
Zoning: PAD-15
Existing Use: disturbed vacant land
Proposed Use: Food Service

TRANSMITTAL DATE: October 14, 2021
DUE DATE: October 14, 2021
COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed.
This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.
1. UDC 2-10.4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.

Ensure that Zoning and Engineering comments are addressed prior to landscape section approval.

2. Please provide all landscape calculations on the landscape plan, including required trees for the parking areas, Admin. Manual 2-10-4.2.A.2.c and landscape borders, UDC Technical Standards 2-10.4.2.f & g.

3. Per Admin. Manual 2-10-4.2.D, provide page/detail reference to civil drawings/details that show bike racks, walkways, and screening/retaining walls on landscape plans. See civil drawing is not sufficient.

4. Depress all landscape areas a minimum of 6” to maximize water harvesting, show detail or section on plans.

5. Grading, hydrology, and landscape plans must be integrated to make maximum use of site storm water runoff for supplemental on-site irrigation purposes. The landscape plan shall indicate use of all runoff, from individual catch basins around single trees to basins accepting flow from an entire vehicular use area or roof area. UDC 7.7.6.C.2. The landscape and grading plans must match.

6. Identify the point of drainage off roof areas, amount of flow, and disposition of flow.

7. Solely using the 40’ trunk to parking space requirement or placing trees only along the edge of a parking area does not meet the intent of the UDC. The intent is to provide as much shade on the asphalt as possible, and the requirement is 1 tree per 4 parking spaces; trees are expected to be placed within the parking area itself. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a. Please revise parking area to ensure trees provide shade over asphalt.

8. Please add/call out soil moisture gauge/tensiometers and rain shut-off device on irrigation plans and details. UDC 4.2.A.

9. A 10’ street landscape border is required along SML King Jr. Way. Please provide information about who is responsible for landscape/irrigation along this roadway.



RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

YOUR NEXT STEPS: Submit documents to the Filedrop
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
Select "Existing Application"
1) Comment Response Letter (your response to
the reviewer's Requires changes comments)
2) Plan Set (or individual sheets)
3) Any other items requested by review staff

If you have any questions, please contact me at anne.warner@tucsonaz.gov
10/14/2021 SBEASLE1 COT NON-DSD PARKS & RECREATION Approved Email from: Howard Dutt
To: CDRC
Wed 10/13/2021 10:51 AM

No existing or proposed Tucson Parks and Recreation facilities are affected by this development.

Howard B. Dutt, RLA
Landscape Architect
Tucson Parks and Recreation
(520) 631-2030
10/14/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
10/20/2021 SBEASLE1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Approved (This can be viewed in "Documents" in PRO: "Tucson Airport Authority, approval letter")

October 14, 2021

RE: DP21-0246 Site/Grading - Wendys Restaurant, The Bridges Sub-Area B-3. Lot 3. 1710 E TUCSON MARKETPLACE BL, 1st submittal, Received September 27, 2021

Thank you for the opportunity to comment on DP21-0246 Site/Grading - Wendys Restaurant, The Bridges Sub-Area B-3. Lot 3. 1710 E TUCSON MARKETPLACE BL, 1st submittal, a development package application for a 1.6 acre site, which is located southwest of the intersection of East Tucson Marketplace Boulevard and South Kino Parkway.
The property is zoned Planned Area Development 15 (PAD-15) and the project would support the development
of a new restaurant.

This site is within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace.

The Tucson Airport Authority approves the proposed project and has no additional comments to provide.

Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811.

Respectfully,
Scott Robidoux, C.M., Senior Airport Planner
10/22/2021 SBEASLE1 UTILITIES TUCSON ELECTRIC POWER Approved (The "TEP APPROVAL LETTER, 10.21.21", "TEP FACILITIES MAP, 10.21.21", and "TEP REDLINE PAGE, 1st SUBMITTAL REVIEW, 10.21.21" can be viewed in the Documents section of PRO.)

October 21, 2021

SUBJECT: Wendy’s Restaurant at The Bridges
DP21-0246

Tucson Electric Power Company (TEP) has reviewed and approved the development plan
submitted September 27th 2021. There do not appear to be any conflicts.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer.

In order to apply for electric service, call the New Construction Department at (520) 918-8300.
Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans.

If easements are required, they will be secured by separate instrument. Your final plans should be sent to:
Tucson Electric Power Company
Attn: Ms. Bianca Maubach
New Business Project Manager
P. O. Box 711 (OH 204)
Tucson, AZ 85702
520-307-3864

Should you have any technical questions, please contact the area Designer Martin Rodriguez (520) 991-5495.

Sincerely,
Conor Mahoney, Office Support Assistant
Design/Build
10/25/2021 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved Email from: Jay Gomes <jgomes@azdot.gov>
To: CDRC
Mon 10/25/2021 3:51 PM

ADOT has no comments on this development. We appreciate the opportunity to review.
11/01/2021 JPEELDA1 COT NON-DSD FIRE Reqs Change Please provide the distance from the existing hydrant to the furthest part of the building as the hose lays. If the building is not sprinklered the distance shall not exceed 400'. IFC 2018 507.5.1

Questions:
Jennifer Peel-Davis
520-837-7033
Jennifer.Peel-Davis@Tucsonaz.gov
11/04/2021 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Completed
11/05/2021 SBEASLE1 COT NON-DSD TRAFFIC Approved Email from: John Van Winkle
To: Sharon, Loren, Stephen
Cc: David Stiffey
Fri 11/5/2021 11:10 AM

This project impacts a "private" street so to that end we do not have any Traffic comments.
12/08/2021 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. A PC RFCD Facility Impact Permit will be required for the new drainage structure into the Greyhound Wash. Coordinate with the district for this project.
2. Show the correct SVTs for the PAAL/Driveway to the private street.
3. Demonstrate how water harvesting is maximized. For example, the drainage from the paved vehicle use areas bypass the adjacent landscape areas.
4. Depress all landscape areas 6 to 9 inches for water harvesting. This should also allow additional depth for ground cover.
5. Provide construction details for water harvesting/landscape areas and the retention/detention basins. Account for ground cover in the proposed grades.
6. Show dimensions for sidewalks at representative locations. Show the clear dimension at the accessible parking signs.
Loren Makus
loren.makus@tucsonaz.gov
12/09/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
to: lisa bowers
Thu 12/9/2021 4:54 PM

Returned for Corrections: DP21-0246
DESCRIPTION: Site/Grading - Wendys Restaurant, The Bridges Sub-Area B-3. Lot 3.

Fee Balance: $0 (zero)

SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab to see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW

INCLUDE IN RESUBMITTAL
1) Comment Response Letter (your response to REQUIRES CHANGE comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your SECOND submittal documents according to this example: 2_Comment Response Letter

FILEDROP for your Resubmittal
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
- Select "Existing Application"
- In the "Permit Number" field, enter the number and, if applicable, any notes for our staff


Sharon Beasley, Building Permit Specialist

City of Tucson, Planning and Development Services
Email: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)