Permit Number: DP21-0209
Parcel: 13337006L

Review Status: Completed

Review Details: DEV PKG - OK TO SUBMIT

Permit Number - DP21-0209
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/13/2021 SBEASLE1 START PLANS SUBMITTED Completed
08/13/2021 SBEASLE1 PIMA COUNTY - ADDRESSING PIMA COUNTY - ADDRESSING Passed Email from: <Addressing@pima.gov>
To: CDRC
Fri 8/13/2021 1:04 PM

This project does not require review by Pima County Addressing.
Thank you
Nicholas Jordan, Addressing Specialist

Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-9623
08/18/2021 LOREN MAKUS ENGINEERING REVIEW Approved
08/19/2021 ELISA HAMBLIN ZONING REVIEW Reqs Change August 19, 2021
DP21-0209 Grading Plan – Carrillo Residence, 975 M Circle D Wy

Please update the plan set with the following information:
1. A small, project-location map shall be provided in the upper right corner of the cover sheet. This map shall cover approximately one square mile, be drawn at a minimum scale of three-inch equals one mile, and provide the following information; a. Show the subject property approximately centered within the one square mile area. Identify major streets within the square mile area and all streets that abut the subject property. Section, township, and range, north arrow, and the scale will be labeled.
2. The north arrow, and scale as applicable to each sheet should be placed together in the upper right corner of each sheet.
3. A legend that shows and describes all symbols used on the drawing is to be provided, preferably on the first sheet.
4. An index of sheets in the development package shall be provided on the first sheet.
5. The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet. The applicable registration or license number shall be provided if prepared by or with the assistance of a registered professional, such as a surveyor, architect, landscape architect, or engineer. All sealing shall be consistent with Arizona Board of Technical Registration guidelines.
6. As a general note, state “Existing zoning is ____.”
7. As a general note, state the gross area of the site by square footage and acreage.
8. Provide a title block on each sheet of the plan set with the following information: The proposed name of the project, or if there is no name, the proposed tenant’s name. A brief legal description is to be provided. The page number and the total number of pages in the package (i.e., sheet xx of xx). The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet. Provide development package case number DP21-0209.

Elisa Hamblin, AICP
Site Review Section Manager
08/20/2021 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Passed