Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP21-0130
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/28/2021 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 06/03/2021 | SBLOOD1 | ENGINEERING | REVIEW | Reqs Change | Development Package Comments: Sheet 1 1. On Elm St, Call out keynote 4 appeared to point to 6" concrete sidewalk. Please clarify whether it is key note 9 or 4. 2. Keynote 2 (near corner of Alley and 1st Ave) pointed to an existing curb along 1st Ave. If there is a remove and replace of the existing curb, please add new keynote number. 3. Key Note 7 (at middle of the Site Plan along 1st Ave): Per PAG Detail 207, apron width should be 3' and 2' wide. It looks like the Site Plan shows only 3' and 1.5' wide. 4. For Key Note 7 (at corner of 1st Ave and Alley), Per PAG Detail 207, apron width should be 3' and 2' wide. It looks like the Site Plan shows less than 2' wide at both sides of aprons. 5. It appears that key note 19 does not appear on this Site Plan. Please remove or revise accordingly. 6. Please provide additional cross section in North-South and West-East directions. 7. Please clarify Legal Description. Title block called out "..... section 6, township 14 South, Range 13 East" ; however, the Location Map called out "Section 6, township 14 South, Range 14 East" 8. It appears that the unloading area requires additional space. Sheet 2 9. For Key note 6 on Utility Plan, please show existing water meter 10. Section A-A, please label dimension from building to P/L 11. For Utility key note 7: Please reference Valve Detail and sheet number 12. Please label (example: TC, FG) all proposed elevations 13. Please provide finished pad grades for all buildings - show slopes away from buildings. 14. TC grades appear to be higher than FFE. Minimum 2% drainage away from building is required. 15. At access driveway, please verify drive slope to insure landing meets City slope standard. 16. For Section A-A, it appears the building encroach into 4ft sidewalk. Please verify necessary vertical clearance. Drainage Comments: 1. Show locations of inflow into water harvesting basins. Review and Comments provided by third party engineer reviewers under contract with the City of Tucson. For Questions or Concerns contact: Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 06/16/2021 | ELISA HAMBLIN | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL FROM: Elisa Hamblin, AICP; Site Review Section Manager PROJECT: 701 E Elm St, Development Package (1st Review), DP21-0130 TRANSMITTAL DATE: June 16, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is May 25, 2022. 1. 2-06.3.5 - A three-inch by five-inch space shall be reserved in the lower right quadrant of each sheet for an approval stamp. 2. 2-06.3.6 - Provide a blank three-inch by five-inch block in the lower right corner of the plan adjacent to the title block on the first sheet of the development package for use by Pima County Addressing. 3. 2-06.4.2.B - In the title block, a brief legal description and a statement as to whether the project is a resubdivision are to be provided. The current legal description of this parcel is UNIVERSITY HOME LOTS 9 & 10 BLK 3. Correct Range in title block, as it should be 14 East not 13 East. 4. 2-06.4.2.D – In the title block, correct sheet numbering. Sheets 3 and 4 are both labeled as Sheet 3. 5. 2-06.4.3 – The relevant case number DP21-0130 shall be provided adjacent to the title block on each sheet. 6. 2-06.4.4.A – On the project location map, show the subject property approximately centered within the one square mile area; 7. 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. Revise General Note 3 to identify Multifamily Development is permitted subject to use-specific standards 4.9.7.B.6, .9, & .10. 8. Correct General Note 7. The maximum allowed building height is 30 ft. 9. 2-06.4.8.B – Verify all existing easements are drawn on the plan. The recordation information, location, width, and purpose of all easements on site will be stated. Blanket easements should be listed in the notes, together with recordation data and their proposed status. Should an easement not be in use and be proposed for vacation or have been abandoned, so indicate. However, should the easement be in conflict with any proposed building location, vacation of the easement shall occur prior to approval of plan unless written permission from easement holder(s) is provided. 10. 2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to (including across Elm St) or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, utility locations and sidewalks. 11. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. Define boundary of C-1/R-2 in alley north of subject parcel. 12. 2-06.4.9.H.5 - If utilizing parking area access lanes (PAALs), they shall be designed in accordance with Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. The minimum width of a two-way PAAL accessing 90-degree parking is 24 ft. A Parking Design Modification Request (PDMR) may be requested to reduce the required 24 ft by a maximum of 10%. 13. 2-06.4.9.H.5.a - The drawing should indicate parking space locations for the physically disabled. The proposed accessible parking space must meet standards for van accessibility. This requires either an 8 ft access lane and 8 ft parking space, or a 5 ft access lane and 11 ft parking space. Additional comments regarding accessible parking will be provided on the next review. 14. 2-06.4.9.H.5.d - Show bicycle parking facilities fully dimensioned. For specifics, refer to Section 7.4.9, Bicycle Parking Design Criteria, of the UDC. Provide, as a note, calculations for short and long term bicycle spaces required and provided. Correct the short-term bike rack dimensions from the wall as the minimum requirement is 2.5 ft. Correct General Note 9.B. to include the calculation for long-term bike parking. 15. 2-06.4.9.L – Verify all proposed easements are illustrated on the plans. All proposed easements (utility, sewer, drainage, access, etc.) are to be dimensioned and labeled as to their purposes and whether they will be public or private. The easements may have to be recorded and the recordation information added to the development package prior to approval. 16. 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s). 17. 2-06.4.9.V - For gang mailboxes indicate location to assure there are no conflicts with other requirements, such as pedestrian accessibility, utilities, and landscaping. 18. 2-06.4.9.W - Indicate the locations and types of proposed signs (wall, free-standing, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. Indicate if there are any existing billboards on site. Compliance to the Sign Code, Chapter 3 of the Tucson Code, is required. 19. General comment – clarify locations of screen walls on the site plan (sheet 1) as well as any perimeter walls with the height clearly identified. Please note per UDC Article 7.4.6.D.2.b. a parking space is required to be 10 feet wide when adjacent to a barrier (such as the screen wall). If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 06/23/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 06/29/2021 | AWARNER1 | LANDSCAPE | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, PLA PDSD Landscape/Native Plant Preservation Section PROJECT: 1st Ave Elm Homes ACTIVITY NO: DP21-0130 Address: 701 E. Elm St. Parcel: 123-15-015A Zoning: R-2 Existing Use: vacant land Proposed Use: Multi-family TRANSMITTAL DATE: June 29,2021 DUE DATE: June 25, 2021 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed. This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting. 1. The NPPO exception is not approved. When submitting an exception request the applicant must provide photos and an aerial prior to grading the entire site. 2. UDC 2-10.4.1 Identification and Descriptive Data A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. The development package will contain the following identification in the lower right corner of each sheet: Any relevant case numbers for reviews or modifications that affect the site. Provide Case # on each sheet. Ensure that Zoning and Engineering comments are addressed prior to landscape section approval. 3. Per 2-10-4.2.D, provide construction details or reference sheet and detail numbers on civil drawings that show bike racks, walkways, retaining and screening walls. 4. Please identify whether there is a wall along the east, north and south sides of the property, include the height. 5. An interior Landscape Border is required along the eastern boundary. UDC table 7.6.4-1. 6. Provide a maintenance schedule for the landscape and irrigation for this project. UDC 2-10-4.2.A.4. 7. All parking spaces must be with 40’ of a canopy tree. Ensure that trees in vehicular use areas are planted within and adjacent to parking so that they afford the greatest amount of shade in paved areas, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a. 8. Include parking area tree calculations, 2-10-4.2.A.2.c 9. The landscape border must be measured from the future right of way for First Ave., please show the future right of way, UDC 7.6.4.C.2.a. and dimension the 10’ landscape border and indicate where the landscape will encroach into the right of way. 10. The calculations for the vegetative cover are incorrect, there is not 630 sf of plant materials for 1st Ave, nor 500 sf on Elm St. 11. A Commercial Water Harvesting plan, in compliance with Technical Standards Manual, 4-01.0.0 is required. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package If you have any questions, please contact me at anne.warner@tucsonaz.gov |
| 06/29/2021 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Please show the existing fire hydrants on your drawings. Also, provide documentation of distance from hydrant to the furthest part of each building as the hose lays. If you have any questions, please call or email me. Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 |
| 07/01/2021 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | Email from: COTDSDPermits To: P Salonga Thu 7/1/2021 12:32 PM Returned for Corrections Notice DP21-0130 DESCRIPTION: Site/Grading - 1Ave Elm Homes. Units 1 through 5. 701 E ELM ST FEES DUE: $ 771.10 Please pay at a minimum, the REVIEW Fees. A payment is required before your next submittal. Thank you. ONLINE PAYMENT If amount isn't correct, check back in a few hours after it is updated. https://www.tucsonaz.gov/pdsd/fees 1- Click on: Pay Planning & Permit Fees 2- Enter your Permit Nbr, example: dp20-0000 (not case-sensitive but a hyphen-dash- is needed) 3- Business/Individual Name: Leave this field blank 4- Click "Continue" 5- Pay column - check the boxes 6- Click "Continue" INCLUDE IN YOUR RESUBMITTAL 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff Please title your 2nd submittal documents according to this example: 2_Comment Response Letter, 07.01.21 FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp (Select "Existing Application", then enter your permit number) SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab and you will see different sections - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW Sharon Beasley, Permit Specialist City of Tucson, Planning and Development Services Email for Development Pkgs: COTDSDpermits@TucsonAz.gov (disregard the email response that will be sent automatically) Email for Building Permits: PDSDinquiries@TucsonAz.gov |
| 07/01/2021 | SBEASLE1 | PIMA COUNTY - ADDRESSING | PIMA COUNTY - ADDRESSING | Needs Review | Applicant: Please send email to Addressing@Pima.gov or call (520) 724-9623. An review fee must be paid to Addressing office before their review can begin. (Review not started yet.) Thank you. |