Permit Number: DP21-0108
Parcel: 13316020X

Address:
6565 E GRANT RD

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP21-0108
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/28/2021 SBEASLE1 START PLANS SUBMITTED Completed
04/28/2021 SBEASLE1 COT NON-DSD REVIEW Approved Email from: Christopher Blue
To: CDRC
Wed 4/28/2021 11:07 AM

The Transit Services Division and Sun Tran have no comments.
Thank you,
Christopher Blue
Transit Services Coordinator | Transit Services Division
Department of Transportation & Mobility, C: 520.260.9558
05/04/2021 SBEASLE1 PIMA COUNTY PIMA COUNTY - REGIONAL FLOOD CTRL DIST Reqs Change Email from: Ann Moynihan <Ann.Moynihan@pima.gov>
To: CDRC
Tue 5/4/2021 1:58 PM

RE: DP21-0108, Popeye's

1. Show existing Drainage Easements on the site plan. Any work, including grading and paving, within the easement requires a Facility Impact Permit from the Regional Flood Control District.

2. Please verify any existing drainage infrastructure into the Pantano Wash. It’s not clear from the aerial photo if there is an existing small diameter pipe adjacent to this project.

3. The District strongly discourages construction of a new outlet to the Pantano Wash. Requirements would include, but not necessarily be limited to, concrete pipe, removal of a wedge of soil cement for placement of a new pipe in accordance with District Standard DS-304, hydraulic calculations with determination of the impact of the Pantano Wash floodplain on the pipe and on the project, and a junction structure at the property boundary to separate public and private maintenance responsibilities.
Instead of construction of a new pipe outlet, the District recommends updating the drainage report to clearly show existing conditions drainage patterns and not changing those patterns.
The site is already impervious and substantial increased peak discharges are not anticipated. Maximizing use of shallow retention should result in stormwater management that does not require a new outlet to the Pantano Wash.
05/06/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
05/17/2021 JPEELDA1 COT NON-DSD FIRE Approved
06/02/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PPDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Popeyes – 6565 E Grant Rd
Development Package (1st Review)
DP21-0108

TRANSMITTAL DATE: June 2, 2021

DUE DATE: May 26, 2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is April 27, 2021.

2-06.3.0 FORMAT REQUIREMENTS

1. COMMENT: 2-06.3.7 - A small, project-location map shall be provided in the upper right corner of the cover sheet, see requirements below.

CONTENT REQUIREMENTS

2. COMMENT: 2-06.4.1 – Provide the email addresses for all listed under “DESIGN AND DEVELOPMENT CONTACTS”.

3. COMMENT: 2-06.4.2.D – Provide the page number and the total number of pages in the package (i.e., sheet xx of xx) within the title block.

4. COMMENT: 2-06.4.3 – Provide the development package case number, DP21-0108, adjacent to the title block on all sheets.

5. COMMENT: 2-06.4.4 - The project-location map to be located on the first sheet of the development package in the upper right corner, shall cover approximately one square mile, be drawn at a minimum scale of three-inch equals one mile, and provide the following information.

6. COMMENT: 2-06.4.4.A – Show the subject property approximately centered within the one square mile area;

7. COMMENT: 2-06.4.4.B - Identify major streets and regional watercourses within the square mile area and all streets that abut the subject property; and,

8. COMMENT: 2-06.4.4.C - Section, township, and range; section corners; north arrow; and the scale will be labeled.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

9. COMMENT: 2-06.4.7.A.1 - List as a general note: "Existing zoning is C-1."

10. COMMENT: 2-06.4.7.A.2 - List as a general note: List the gross area of the site by square footage and acreage.

11. COMMENT: 2-06.4.7.A.4 - List as a general note: List the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses.

12. COMMENT: 2-06.4.7.A.6.a – Provide a general note stating: “THIS PROJECT IS DESIGNED TO MEET THE OVERLAY ZONE(S) CRITERIA, UDC ARTICLE 5.4 MAJOR STREETS AND ROUTES SETBACK ZONE (MS&R).”

2-06.4.7.A.8 - For development package documents provide:

2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

13. COMMENT: 2-06.4.8.A – The site boundary perimeter information is difficult to read.

14. COMMENT: 2-06.4.8.B – Provide the recordation information for all existing easements shown on the plan.

15. COMMENT: 2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the dimensioned width of paving, curbs, curb cuts, and sidewalks.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

16. COMMENT: 2-06.4.9.H.2 - Show future and existing sight visibility triangles. On a designated MS&R street, the sight visibility triangles are based on the MS&R cross-section.

17. COMMENT: 2-06.4.9.H.5 – Per UDC Article 7.4.6.F.2.a.(2) show the required 1’-0” setback the building to the drive-through.

18. COMMENT: 2-06.4.9.H.5 – Show and dimension the required vehicle stacking for the drive-through, see UDC Article 7.4.7.

19. COMMENT: 2-06.4.9.H.5.a – The wheel stop location dimension is not shown correctly, see UDC Article 7.4.6.H.3.
20. COMMENT: 2-06.4.9.H.5.d – Provide a short - term bicycle parking space calculation on the plan. This calculation shall include the number required & provided.

21. COMMENT: 2-06.4.9.H.5.d – Provide a short – term bicycle parking space detail that clearly demonstrates how the requirements of UDC Articles 7.4.9.B1, B2 & C are met.

22. COMMENT: 2-06.4.9.L – As vehicle access is proposed to the adjacent properties some type of access easement or easement is required. Provide a copy of the recorded document and provided the information on the plan.

23. COMMENT: 2-06.4.9.O – The street perimeter yard setback is not shown correctly on the plan. Per the definition of Established Area Setback any property bordering on a street designated on the COT Major Streets and Routes plans is considered developing area, see UDC Article 11.4.6. Per UDC Article 6.4.5.C.2 and Table 6.4.5-C.1 the required street perimeter yard setback is measured from the back of curb. Until the height of the building is provided, see comment 24, the required distance cannot be verified.

24. COMMENT: 2-06.4.9.Q – Provide the height of the proposed building within the footprint on the plan.

25. COMMENT: 2-06.4.9.R – Per TSM Section 7-01.4.1.B A sidewalk is required adjacent and parallel to any access lane or PAAL on the side where buildings are located. That said provide a sidewalk along the south side of the building.

26. COMMENT: 2-06.4.9.R – As vehicles are allowed to overhang sidewalks show the 2’-6” allowed vehicle overhang on the plan.

27. COMMENT: 2-06.4.9.W – Provide a general note on the plan stating “ALL SIGNS REQUIRE A SEPARATE PERMIT”.

If you have any questions about this transmittal, please contact Elisa Hamblin or Elisa.Hamblin@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
06/07/2021 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. Any work within the Pima County Regional Flood Control District property requires a Facility Impact Permit from the District. Provide copies of approvals from the district with the next submittal.
2. Number all pages of the drainage report.
3. In the drainage report, show the existing drainage areas and discharge quantities. Show the existing discharge locations and quantities. Explain any change in discharge location.
4. Provide the calculations supporting the rip rap sizing described on sheet 4 of the drainage report.
5. In the drainage report, provide a more complete and accurate description of the existing conditions.
6. Show proposed drainage patterns and show how water harvesting is maximized.
7. Show how solid waste service trucks will access the container location. Show maneuverability and access diagram. Show the required 14-foot by 40-foot service area.
8. Show roof drainage and show that sidewalks will be kept flood free for up to a 10-year event.
06/09/2021 AWARNER1 LANDSCAPE REVIEW Reqs Change CDRC TRANSMITTAL

TO: Planning and Development Services Department, Plans Coordination

FROM: Anne Warner, PLA
PDSD Landscape/Native Plant Preservation Section

PROJECT: Popeyes Fast Food Restaurant
ACTIVITY NO: DP21-0108
Address: 6565 E. Grant Road
Parcel:
Zoning: C-1
Existing Use: Developed property
Proposed Use: Commercial Food Service

TRANSMITTAL DATE: June 9, 2021
DUE DATE: May 26, 2021
COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed.
This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.
1. UDC 2-10.4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.

The development package will contain the following identification in the lower right corner of each sheet:
Any relevant case numbers for reviews or modifications that affect the site.
Provide all related activity numbers and the development package # on each sheet.
Ensure that Zoning and Engineering comments are addressed prior to landscape section approval.

2. Label all trees to be preserved in place.
3. A street landscape border is required per UDC Table 7.6.4-1. Landscape Border and Technical Standards Manual 5-01.4.0. Existing vegetation can be used in the street border, please provide existing species and size to be supplemented with the required density of vegetation.
4. Provide square footage of the vehicular use area; number of parking spaces, including the required and provided parking space calculations; and the calculation of the required number of canopy trees. Trees are required within the parking area at a density of 1 canopy tree/4 parking spaces. Parking islands with canopy trees are preferred.
5. A landscape border is required along the RX-1 zone boundary to the northeast. See Table 7.6.4-1.
6. Provide the length and width of landscape borders on the plan and number of canopy trees per length; provide the square footage of all landscaped borders and calculation of the percentage of vegetative coverage.
7. Provide a plant Maintenance Schedule that includes;
a. Pruning schedules to show that plant material will maintain pedestrian and vehicular clearances or that the material will establish opaque screens, if required;
b. Replacement criteria, should plant material not survive;
c. Replacement or upkeep maintenance schedules for inert ground cover materials;
d. Upkeep maintenance schedules for exterior hardscape materials; and,
e. Maintenance and replacement schedules for irrigation systems.
8. An Irrigation Plan is required that includes;
a. Type of water conserving irrigation systems proposed and differentiation between systems for the different water use zones on the site;
b. Source of irrigation water;
c. Indicate potable or reclaimed water use. Reclaimed water system specifications, if used;
d. System specifications and system design and layout (Section 4-01.4.2, Irrigation Standards, of the Technical Standards Manual);
e. Extent of supplementary irrigation in each planting area, provided by water harvesting methods;
f. Point of drainage off roof areas, amount of flow, and disposition of flow;
g. Temporary systems proposed to establish native seeded areas;
h. The length of irrigation duration (e.g., for native plat material, automatic drip for two years or until established); and,
i. The extent to which systems are proposed within the public right-of-way.
9. A Commercial Rainwater Harvesting plan is required in accordance with the UDC Technical Standards Manual – Section 4-01.0.0. Commercial Rainwater Harvesting and Section 5-01.0.0 Landscaping and Screening


RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package

If you have any questions, please contact me at anne.warner@tucsonaz.gov
06/16/2021 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change Email from: COTDSDPermits
To: WFellhoelter
Wed 6/16/2021 1:44 PM

Returned for Corrections Notice
PERMIT/ACTIVITY: DP21-0108

DESCRIPTION: Site/Grading/Swppp - Popeye's Louisiana Kitchen. New restaurant. 6565 E GRANT RD

FEE BALANCE: $0 (zero) Thank you for the payment.

INCLUDE IN YOUR RESUBMITTAL
1) Comment Response Letter
(your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

Please title your 2nd submittal documents according to this example: 2_Comment Response Letter, 01.01.21

FILEDROP
https://docs.tucsonaz.gov/Forms/tucsonpermitapp
(Select "Existing Application", then enter the permit number)

SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, Activity Search, enter the Activity/Permit Number
- Permits - click on blue tab and you will see different sections
- Reviews section - click on REVIEW DETAILS
- Documents section - click on VIEW


Sharon Beasley, Permit Specialist

City of Tucson, Planning and Development Services
Email for Development Pkgs: COTDSDpermits@TucsonAz.gov
(disregard the email response that will be sent automatically)
Email for Building Permits: PDSDinquiries@TucsonAz.gov
06/16/2021 SBEASLE1 COT NON-DSD TRAFFIC Reqs Change Email from: <David.Stiffey@tucsonaz.gov>
To: CDRC
Wednesday, June 16, 2021 1:27 PM

DP21-0108 Comments:

1. Key Note No. 4 page C4. Curb returns are to be 25 Ft Radius. If curb returns are not feasible at this location, a P.A.G. standard 206 Driveway Apron is acceptable.
2. Curbing in the ROW must be constructed to P.A.G. standard 209.
3. Sight Visibility Triangles need to be noted according to COT Technical Manual- 10-01.5.3 (line of sight matrix)
4. Any existing sidewalk along the frontage of the property that is out of compliance will be upgraded as needed.
5. Existing sidewalk must be a minimum of 5’ wide.
6. Sidewalk in the ROW must be constructed to P.A.G. standard 200.


David Stiffey