Permit Review Detail
Review Status: Completed
Review Details: REVISION - - 1ST
Permit Number - DP21-0026
Review Name: REVISION - - 1ST
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/22/2022 | SBEASLE1 | ENGINEERING | REVIEW | Reqs Change | (These review comments are from the recent OK to Submit) 1. Rezoning condition 1.D. requires a decorative masonry wall on the south and east perimeter. Show compliance with all the requirements of this condition. 2. Show how water harvesting is maintained with the new driveway to the street. Loren Makus loren.makus@tucsonaz.gov |
| 06/30/2022 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | FROM: Development Services Department Zoning Review PROJECT: 1526 N Alvernon Ave Development Package (Revision #1 -1st Review) DP21-0026 TRANSMITTAL DATE: June 30, 2022 DUE DATE: July 05, 2022 COMMENTS: Please resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 1. COMMENT: 2-06.4.9.U – The proposed revisions do not meet Rezoning C9-95-10 conditions 1.d and 1.f. Either provide documentation that the conditions and PDP have been revised or revised the plan to meet these conditions. If you have any questions about this transmittal, please contact Nicholas Ross at Nicholas.Ross@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 07/11/2022 | AWARNER1 | LANDSCAPE | REVIEW | Approved | |
| 07/18/2022 | JPEELDA1 | COT NON-DSD | FIRE | Reqs Change | Plans shall show the existing and new hydrants and or fire sprinklers shall be installed. Building shall be within 400' of a hydrant to the furthest part as the hose lays and or fire sprinklers shall be installed IFC 2018, 507.5.1 Fire department access roads shall be 20' wide IFC 2018, 503.2.1 Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 Fire Plans Examiner |
| 08/18/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Approv-Cond | DP21-0026 Comments: 1. Sheet 3- Existing sidewalk along Alvernon Way may remain if it is within tolerance of current standards. 2. Sheet 3- Any existing sidewalk that is less than 4' wide, will need to be widened to 5'. 3. Sheet 3- The existing curb access ramp on the SE corner of Alvernon Way and Lee St. may remain if it is within tolerance of current standards. David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
| 08/19/2022 | SBEASLE1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | Email from: COTDSDPermits to: lisa bowers 08/19/2022 REVISION REVIEW NOTICE Revision returned for corrections, DP21-0026 Project Description: Site/Grading/SWPPP - 1526 N. Alvernon Way, three new commercial bldgs, one new food service bldg with drive-thru. FEE BALANCE: $0 (zero) VIEW the review comments and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document YOUR NEXT STEPS: Submit documents to the Filedrop https://docs.tucsonaz.gov/Forms/tucsonpermitapp Select "Existing Application" 1) Comment Response Letter (your response to the reviewer's Requires changes comments) 2) Plan Set (or individual sheets) 3) Any other items/documents requested by review staff Sharon Beasley, Certified Permit Technician City of Tucson, Planning & Development Services Dept. Email: COTDSDpermits@TucsonAz.gov (for development packages, land splits, Thursday Presubmittal meetings) Email: PDSDinquiries@TucsonAz.gov (for building permits) |