Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP20-0214
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/23/2020 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 10/23/2020 | SBEASLE1 | ENGINEERING | REVIEW | Approved | Approved by Loren Makus during OK to Submit, 10/22/20. |
| 10/23/2020 | SBEASLE1 | ZONING | REVIEW | Approved | Approved by Steve Shields during OK to Submit, 10/19/20. |
| 10/29/2020 | GDAURIA1 | FIRE | REVIEW | Completed | |
| 11/23/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Correct utility keynote 3 on sheet C-02: a reduced pressure principle backflow prevention assembly is to be installed, not a backwater valve. |
| 11/24/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | ADMINISTRATIVE MANUAADMINISTRATIVE MANUAL 4.1 Identification and Descriptive Data The Development Package will contain the following identification in the lower right corner of each sheet: Any other relevant case number for reviews or modifications that affect the site. Page Break Add case number and DP20-0215 on each sheet. Ensure that Zoning comments are addressed prior to landscape section approval. |
| 11/25/2020 | FRANK PODGORSKI | HPZ ADVISORY BOARD | HPZ ADVISORY BOARD DATE | Reqs Change | 11/25/20 I have reviewed the plans for the restroom building. The rendering and materials are consistent with HPZ review recommendations. HPZ review process approved what is submitted. The approval letter is still pending review fee to be paid by applicants. At this time, an approval decision has not been issued by PDSD Director. Once payment is effectuated an approval letter will be generated to complete the HPZ process. Let me know if any questions Thanks Michael Taku, MS, Historic Design Review Coordinator Lead Planner City of Tucson Planning and Development Development Services 520.837.4963 www.tucsonaz.gov/historic-preservation |
| 11/25/2020 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | DATE: November 25, 2020 RETURNED FOR CORRECTIONS NOTICE Your Next Steps: 1. Payment 2. Resubmittal of updated/corrected documents IMPORTANT - NEW FILEDROP: https://docs.tucsonaz.gov/Forms/tucsonpermitapp Select "Existing Application" For all NEW submittals on the upload page, select the box: "Site Review..." so it is routed to correct staff member for quick processing. PERMIT/ACTIVITY: DP20-0214 DESCRIPTION: SITE - Anza Park, restroom building. FEES DUE: $ 594.00 Please pay the total fees (or at a minimum, the REVIEW Fees). A payment is required before your next submittal. ONLINE PAYMENTS https://www.tucsonaz.gov/pdsd/fees IMPORTANT: If information is not available or amount isn't correct, check back later after data is updated. (Visa, MC, Discover, American Express, or pay from bank account) 1- Click on: Pay Planning & Permit Fees 2- Enter your Permit Nbr, example: dp20-0000 (not case-sensitive but a hyphen-dash- is needed) 3- Business/Individual Name: Leave blank 4- Click the blue tab: Continue 5- Under the Pay column, check the boxes you want to pay 6- Click Continue, then enter your credit card info 7- If any issues, try using the browser Internet Explorer SEE REVIEW COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab - Reviews - click on Review Details - Documents - click on View to the right of each document YOUR NEXT STEP: Submit documents (NEW LINK for all uploads): https://docs.tucsonaz.gov/Forms/tucsonpermitapp 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set (all pages, full set, even if no changes were made) 3) Any other documents requested by review staff - Title the documents for your 2nd submittal starting with the submittal number, for example: 2_Plan_Set City of Tucson Attn: Sharon Beasley, Permit Specialist Planning and Development Services email: COTDSDPermits@TucsonAz.gov |