Permit Number: DP20-0094
Parcel: 12714003H

Address:
373 N WILMOT RD

Review Status: Completed

Review Details: DEV PKG - OK TO SUBMIT

Permit Number - DP20-0094
Review Name: DEV PKG - OK TO SUBMIT
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/29/2020 SBEASLE1 START PLANS SUBMITTED Completed
04/30/2020 ELISA HAMBLIN ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: Sedona Springs Apartments - 373 N Wilmot Rd
Solar Canopies
Development Package (1st Review)
DP20-0094

TRANSMITTAL DATE: April 30, 2020

DUE DATE: OK to Submit

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is April 29, 2021.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)

2-06.4.9.O - Pe UDC TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-3 Zone Nonres Use to Res or Nonres Zone, the required perimeter yard setback is 10' or ¾ the height of the structure. Based on the proposed height the required perimeter yard setback from Canopy E to the east property line is 10'-0", 4.24' is proposed and from Canopy F to the north property line is 10'-0", 4.29' is proposed. A Design Development Option (DDO) or an adjacent neighbor signoff waiver is required.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
04/30/2020 JOHN VAN WINKLE ENGINEERING REVIEW Needs Review
04/30/2020 SBEASLE1 ZONING-DECISION LETTER WRITE DECISION LETTER Passed