Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP20-0018
Parcel: 12307292C

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP20-0018
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/21/2020 SBEASLE1 START PLANS SUBMITTED Completed
01/21/2020 SBEASLE1 ZONING REVIEW Reqs Change (Review comments from Okay to Submit, 01/17/2020)

CDRC TRANSMITTAL
TO: Development Services Department Plans Coordination Office FROM: Steve Shields, Section Manager
PROJECT: Chipotle - 1903 Speedway Blvd, Development Package (1st Review), DP20-0018

TRANSMITTAL DATE: January 17, 2020

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is January 15, 2021.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

1. 2-06.4.9.H.5 - Provide a copy of the cross access agreement with your next submittal.

2. 2-06.4.9.H.5.a - Zoning acknowledges that PDMR is proposed to reduce the number of vehicle parking spaces. The required number of vehicle parking spaces is 32, provided is 28. 3 Space reduction via UDC Article 7.4.10.B.1. A PDMR will need to be submitted and approved prior to approval of the development package. Per UDC Article 7.4.10.C.2.a Review of modification requests to the number of motor vehicle and bicycle parking spaces is in accordance with the Section 3.3.4, 50' Notice Procedure. The Design Review Board (DRB) reviews the request and provides the PDSD Director with a recommendation.

3. 2-06.4.9.H.5.a - The mounting height for the accessible sign shown on detail 2 sheet 1 is not correct and should be 60".

4. 2-06.4.9.H.5.d - Demonstrate on the plan of a detail that the requirements of UDC Article 7.4.9.B.1.d & .e, 7.4.9.B.2.a, .f & g.

5. Remove all deltas and clouds from the plan.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
01/21/2020 SBEASLE1 ZONING HC REVIEW Reqs Change See zoning comments (if applicable).
01/21/2020 SBEASLE1 ENGINEERING REVIEW Approved Approved by Loren Makus on 01.17.2020 (see Okay to Submit).
01/30/2020 ANDREW CONNOR LANDSCAPE REVIEW Approved
01/30/2020 SSHIELD1 COT NON-DSD FIRE Needs Review
01/31/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
Your Next Steps: 1. Payment 2. Resubmittal which includes a Comment Response Letter

DESCRIPTION: SITE - Chipotle Mexican Grill, exterior patio seating.

PERMIT: DP20-0018
Please include this number on all future correspondence and in Filedrop's "Project Description" field.

FEES DUE: $ 429.00
Note: A payment is required before we can accept your resubmittal.
Payment Options. Please pay the total fees (or Review Fees at a minimum):
1. Online Payment
2. In person at the City Permit Counter (Mon-Fri, 8:00 AM to 2:00 PM)
3. By mail - a check payable to the City of Tucson (address is below), include the Activity Number

Online Payment
https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. NOTE: It may take 1-2 days for complete permit information to be available online
2. Visa, MC, Discover, American Express
3. Not case-sensitive but a hyphen is needed, for example: dp19-2000
4. Enter your Permit Nbr. and click the Continue tab
5. Business/Individual Name: Leave blank
6. If any issues, try using the browser Internet Explorer

VIEW REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Documents section, click on blue icon to the right of each document
- Reviews section, click on Review Details

YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff

- Filedrop: In the Project Description field, enter the Activity/Permit Number
- Name your 2nd submittal documents to start with the number, for example: 2_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, 2nd Floor
Tucson, AZ 85701
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
01/31/2020 SBEASLE1 OUT TO CUSTOMER Completed