Permit Number: DP19-0314
Parcel: 12910129A

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP19-0314
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/16/2020 SBEASLE1 START PLANS SUBMITTED Completed
03/26/2020 SBEASLE1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Approved March 23, 2020

RE: DP19-0314 / SITE/GRADING - Cherrybell Medical Center, Phase 2 (revision to DP17-0157), 2nd Submittal, Received March 12, 2020

Thank you for the opportunity to comment on DP19-0314, Cherrybell Medical Center, Phase 2 (revision to DP17-0157), 2nd Submittal, a development package application for an approximately 0.48 acre site, located southeast of the intersection of South Kino Parkway and East 22nd Street. The property is zoned Residence Zone 2 (R-2), Commercial Zone 3 (C-3), and Light Industrial Zone (I-1), with the proposed zoning being Commercial Zone 2 (C-2) and the proposed development being the second phase a medical outpatient (excluding blood donor centers) and residential care service (physical and behavioral health service).

This site is within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace.

The Tucson Airport Authority recognizes the receipt of confirmation that the applicant provided documentation that the FAA identified that filing FAA Form 7460 was not needed. The Tucson Airport Authority is satisfied with the 2nd submittal of this project and has no additional comments to provide.

Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811.

Respectfully, Scott Robidoux, C.M., Senior Airport Planner
04/10/2020 NICHOLAS ROSS ZONING REVIEW Reqs Change CDRC TRANSMITTAL
TO: Development Services Department
Plans Coordination Office


FROM: Nick Ross
Lead Planner

PROJECT:
Development Package (2nd Review)
DP19-0314


TRANSMITTAL DATE: April 10, 2020
DUE DATE: April 10, 2020


COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is December 26, 2020.

1. Kennels for boarding animals (Animal Service) needs to be identified on the plan as an accessory use and is subject to Use Specific Standards 4.9.4.D.3, D.8 & D.15. This use must occur in a completely enclosed building.


If you have any questions about this transmittal, please contact me at Nicholas.Ross@tucsonaz.gov or (520) 837-4029.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
04/10/2020 LOREN MAKUS ENGINEERING REVIEW Approved
04/20/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
04/22/2020 SSHIELD1 LANDSCAPE REVIEW Approved
04/23/2020 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change RETURNED FOR CORRECTIONS NOTICE
Your Next Steps: Resubmittal with a Comment Response Letter

DESCRIPTION: SITE/GRADING - Cherrybell Medical Center, Phase 2 (revision to DP17-0157).

PERMIT: DP19-0314
PROJECT MANAGER: Samuel.Rogers@Tucsonaz.gov
FEE BALANCE: $0 (zero)

SEE REVIEWER'S COMMENTS and your submitted documents on PRO: www.tucsonaz.gov/pro
(If information is not available, check back later after data transfers to PRO.)
- Home page, left side, Activity Search, enter the Activity Number
- Permits section, click on blue tab
- Reviews section, click on Review Details
- Documents section, click on blue icon to the right of each document

YOUR NEXT STEPS: Submit the following items to the Filedrop - https://www.tucsonaz.gov/file-upload-pdsd
1) Comment Response Letter (your response to the reviewer's Requires Change comments)
2) Plan Set (all pages, full set, even if no changes were made)
3) Any other documents requested by review staff

- Name your 3rd submittal documents to start with the submittal number, for example: 3_Plan_Set

NOTE: The City of Tucson's Permit Counter at 201 N. Stone Avenue (the physical office) is closed to the public until further notice. In the meantime, our staff is working remotely from home. All communications are by telephone or email.

CONTACT US: To speak with a staff member on the telephone, please sign into the Virtual Zoning Counter:
https://www.tucsonaz.gov/pdsd/virtual-service-counter
The queue is open from 8:00 am -12:00 noon, Monday -Friday.
It’s better to sign in closer to 8 than 12 noon.
This is similar to the City’s in-person counter.
The difference is after you sign up, we will give you a call.

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
email: COTDSDPermits@TucsonAz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
04/23/2020 SBEASLE1 OUT TO CUSTOMER Completed