Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP19-0175
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/27/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 10/10/2019 | SROGERS2 | ZONING HC | REVIEW | Reqs Change | See zoning comments |
| 10/10/2019 | SAMUEL ROGERS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Samuel Rogers PDSD Zoning Review Section PROJECT: Cherry Mixed Use Lofts Development Package (2nd Review) DP19-0175 TRANSMITTAL DATE: 10/10/2019 DUE DATE: 10/25/2019 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is July 24, 2020. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) Section 6. COMMENT: 2-06.4.7.A.3 - Development package will not be approved until rezoning (C9-19-11) is approved by Mayor and Council. 10. COMMENT: 2-06.4.7.A.6.a - Provide IPP application number on the bottom right of each sheet. 2-06.4.8 - Existing Site Conditions 12. COMMENT: 2-06.4.8.A - Property lines are not allowed to cross through the middle of a building. Lots 12419040E, 12419040F, and 12419040G will need to be combined. Provide a signed Parcel Combo Form of approval or acceptance from the Pima County Assessor's office in the next submittal. 13. COMMENT: 2-06.4.8.B - Provide documentation of vacated easements with next submittal. 23. COMMENT: 2-06.4.9.S - Sidewalk to the west of Building 6 is 6'. Side walk must either be 6.5' or a wheel stop must be provided. 24. COMMENT: Per rezoning conditions, the applicant shall perform a traffic study prior to the approval of this development package. If you have any questions about this transmittal, Samuel Rogers at (520) 791-6932 or by email Samuel.Rogers@tucsonaz.gov or contact Steve Shields at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 10/24/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | ADMINISTRATIVE MANUAL 4.1 Identification and Descriptive Data All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. Indicate graphically, where possible, compliance with conditions of rezoning. Indicate any conditions imposed on cover sheet Development package will not be approved until rezoning (C9-19-11) is approved by Mayor and Council. Ensure that Zoning and Engineering comments are addressed Additional comments may apply |
| 10/25/2019 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Reqs Change | DP19-0175 / 2nd Submittal/ Cherry Mixed Use Lofts is Conditionally Approved by Pima County Addressing subject to the following: · Lot Consolidation · Recorded document for Abandonment of a portion of 16th St currently shown as “to be vacated” · Recorded document conveying title from City of Tucson to Cherry Lofts, LLC of 5405 sq.ft.+ currently shown as “to be vacated” Also, please note all Building Permits need to be corrected to use the project address 555 S Cherry Av Buildings #1-11 Let me know if you have any questions. Thank you, Robin Freiman, Addressing Official Pima County Development Services Department 201 N Stone AV – 4th Floor Tucson, AZ 85701, (520) 724-7570 CC: Ryan Stucki |
| 10/25/2019 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | |
| 10/28/2019 | JOHN BEALL | COT NON-DSD | COMMUNITY PLANNING | Completed | |
| 10/30/2019 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE - A resubmittal is required. Permit/Activity Number: DP19-0175 Project Description: SITE/GRADING/SWPP - Cherry mixed use lofts, Res & Commercial. Lots 30 and 31, Cherry-Campbell redev subdivision. Project Manager: Samuel.Rogers@TucsonAz.gov, (520) 837-6932 Fee Balance: $0 (zero). Thank you for the payment. View the reviewer's comments: www.tucsonaz.gov/pro (If information is not available, check back later as data transfers to PRO periodically.) - Home page, left side, “Activity Search”, enter the Activity Number - “Permits” section, click on blue tab - "Reviews" section, click on "Review Details" Submit the following items to the Filedrop. Before uploading, please enter the Activity Number in the Project Description field. PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd 1) Comment Response Letter (your response to the reviewer's “Requires changes” comments) 2) Plan Set (all pages, full set) 3) Any other documents requested by review staff 4) Name your 3rd submittal documents accordingly, for example: 3_Plan_Set Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, First Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/30/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |