Permit Number: DP19-0147
Parcel: 13711425E

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP19-0147
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/26/2019 SBEASLE1 START PLANS SUBMITTED Completed
09/10/2019 IMONSHI1 ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Iman Monshizadeh
PDSD Zoning Review Section

PROJECT: Irvington Nineteen Storage - Storage Use Group / Personal Storage Use
Development Package (2nd Review) - 1760 W. Irvington Road
DP19-0147 - C-1 Zoning

TRANSMITTAL DATE: September 10th, 2019
DUE DATE: September 24th, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is June 13, 2020.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)
Section

***Address the comments listed under each standard. The standard has been left in its entirety as reference for the zoning reviewer and applicant.

CONTENT REQUIREMENTS
2-06.4.7.A.2 - List the gross area of the site/subdivision by square footage and acreage. Per the applicable use specific standard 4.9.10.C.7, a minimum of 3 acres is required

PREVIOUS COMMENT 5: Comment still applicable. Per general note 2, the square footage of the site is listed as lot 1 and lot 2. Per the Pima County Assessors information what is being listed as lot 1 and 2 is an all parcel. IS the owner/developer proposing to split the lot? If so, has a COT PDSD lot split application been processed? Be sure to list the lot split application case number next to the title block of all DP plan sheets.


2-06.4.9.E - Proposed land splits or existing lot lines shall be drawn on the plan with dimensions and the identification number and approximate square footage of each lot. (Please be aware that, if land division occurs and the number of lots falls within the definition of subdivision, a subdivision plat is required.) Land splits require a separate permit and review.


PREVIOUS COMMENT 9: Comment still applicable. The boundary information will be verified with the lot split survey plan on the next submittal, assuming it is available.


2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.

Previous comments 14, 15, and 17 were not fully addressed



PREVIOUS COMMENT 14: Previous comment not fully addressed. The Van accessible space must be 11 feet wide or the accessible aisle between the two ADA spaces must be increased to 8 feet. Please revise one of the ADA spaces to be a van accessible space with the correct dimensions for the space and access lane shown on site plan and detail sheet.


PREVIOUS COMMENT 15: Previous comment not fully addressed. 2-06.4.9.H.5.d - Show bicycle parking facilities fully dimensioned. For specifics, refer to Section 7.4.9, Bicycle Parking Design Criteria, of the UDC. Provide, as a note, calculations for short and long term bicycle spaces required and provided.


PREVIOUS COMMENT 17: Previous comment not fully addressed. 2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual.


If you have any questions about this transmittal, Contact Iman Monshizadeh at Iman.Monshizadeh@tucsonaz.gov or call (520) 791-5550 and leave a message, or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
09/16/2019 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved DP19-0147 / 2nd Submittal for review / Irvington 19 Storage is Approved by Pima County Addressing.
Thank you,
Robin Freiman, Addressing Official
Pima County Development Services Department
201 N Stone AV – 4th Floor Tucson, AZ 85701
(520) 724-7570
09/23/2019 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL

SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS

4.1 Identification and Descriptive Data

Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.

Prior to landscape approval ensure that all Zoning and Engineering comments are addressed.

Additional comments may apply.
09/24/2019 IMONSHI1 ZONING HC REVIEW Reqs Change
09/24/2019 MASHFOR1 COT NON-DSD FIRE Reqs Change **After a collective review of the plan set we have found the the distance does not meet the threshold based on the measured fire hydrant distance. Please consult with Fire on measurments.

Additional hydrant may be required. A hydrant must be within 600' of all parts of the building, as the hose lays. Please provide dimensions indicating compliance, or add another hydrant on the west side of the project.
10/01/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
10/02/2019 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change 1) Previous comment 7. PAG detail 105 meets requirments for a barrier but does not meet ICC A117 section 505 requirments for a handrail. The height of the gripping surface is to great in the PAG standard. Please review ICC A117 section 505 and provide a detail for a handrail on the plans. See following link
https://codes.iccsafe.org/content/ICCA117_12017/chapter-5-general-site-and-building-elements
2) Engineering can conduct an expedited review once the above comment has been addressed
10/03/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
- A resubmittal is required
Permit/Activity Number: DP19-0147
Project Description: SITE/GRADING/SWPPP - Irvington Nineteen Storage, self-storage facility.
Project Manager: Samuel.Rogers@TucsonAz.gov, (520) 837-6932
The fee balance is $165.00 (two hours Fire review)
Note: We require payment prior to accepting a resubmittal.
Please pay:
1. Online
2. In person at the permit counter (Mon-Fri, 8:00 AM to 2:00 PM)
3. By mail - a check payable to City of Tucson, address is shown below, include the Activity Number

Online Payments (Visa, MC, Discover, American Express)
https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. Total fees due: Payment portal may take 1-2 days to update to the correct total
2. Not case-sensitive but a hyphen is needed, e.g.: dp19-0000
3. Enter your Permit Nbr. and click the “Continue” tab
4. If any issues, try using the browser Internet Explorer.

To view the review comments: www.tucsonaz.gov/PRO, enter Activity Number.
(If information isn't shown yet, check back later as data uploads to PRO periodically.)
Submit the following items to the PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, please include the Activity Number.
1) Comment Response Letter (listing your response to the reviewer's comments and the changes that were made)
2) Plan Set (all pages, full set)
3) Any other documents requested by review staff
4) Name your 3rd submittal documents accordingly, for example: 3_Plan_Set

Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, First Floor
Tucson, AZ 85701

Final Status

Task End Date Reviewer's Name Type of Review Description
10/03/2019 SBEASLE1 OUT TO CUSTOMER Completed