Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP19-0124
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/12/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 09/19/2019 | IMONSHI1 | ZONING HC | REVIEW | Reqs Change | see zoning comments |
| 09/19/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 09/19/2019 | IMONSHI1 | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Iman Monshizadeh Planner PROJECT: Stark Fence Company Development Package (2nd Review) DP19-0124 TRANSMITTAL DATE: September 19th, 2019 DUE DATE: October 10th, 2019 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is May 30, 2020. 2-06.4.8 - Existing Site Conditions 9. 2-06.4.8.A - Previous Comment: It appears that this site is made up of two (2) parcels, 132-16-0420 & 132-16-0430. These parcels will need to be combined. Provide a copy of the approved Pima County Combo Request form with your next submittal. Comment not fully addressed: it does not appear that the preliminary application is signed by any authorized Pima county employee. Please provide a signed Preliminary form. 2-06.4.9 - Information on Proposed Development 10. 2-06.4.9.F - Previous Comment: It appears that development is proposed within the R-1 Zoned portion of this site, a rezoning is required. Follow up comment: Provide the dimension for the water harvesting basin to show it is within the first 25' of the R-1 zone. 16. 2-06.4.9.H.5 - Previous Comment: Please provide a detail for the required long-term bicycle parking. Comment not fully addressed. Provide a detail drawing for the required long term bicycle parking, showing what type of facility is being used, and the dimensions for the parking as shown in figure 7.4.9-C of the UDC. 18. 2-06.4.9.Q - Previous Comment: Provide the specific use proposed within the footprint of the building. Comment not addressed: Please provide the use within the footprint of the building. Specifically In the drawing of the footprint where you have listed "NEW BUILDING, 9250 S.F. TOTAL, TWO STORY, HEIGHT=24'" 23. 2-06.4.9.W -Previous comment: Indicate the locations and types of proposed signs (wall, free-standing, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. Follow up comment: Indicate on document that "all signs require separate permit" If you have any questions about this transmittal contact Iman Monshizadeh at (520) 837-4082 or by email at Iman.Monshizadeh@tucsonaz.gov or contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 09/19/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 09/19/2019 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 09/19/2019 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE - A resubmittal is required Permit/Activity Number: DP19-0124 Description: SITE/GRADING - Stark Fence Company, commercial facility. Project Manager: Andrew.Connor@TucsonAz.gov, (520) 837-4950 The fee balance is $0 (zero). To view the review comments: www.tucsonaz.gov/PRO, enter Activity Number. (If information isn't shown yet, check back later as data uploads to PRO periodically.) Submit the following items to the PDSD Filedrop: https://www.tucsonaz.gov/file-upload-pdsd. In the Project Description field, please include the Activity Number. 1) Comment Response Letter (listing your response to reviewer's comments) 2) Plan Set (all pages, full set) 3) Any other documents requested by review staff 4) Name your 3rd submittal documents accordingly, for example: 3_Plan_Set Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, First Floor Tucson, AZ 85701 |
| 09/24/2019 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Approved | DP19-0124 / 2nd subm. for review / Stark Fence is conditionally approved. We respectfully request a permitting condition stating that a Certificate of Occupancy will not be issued until a parcel consolidation is granted by the Pima County Assessor’s Office. Thank you Nicholas Jordan, Addressing Specialist Pima County Development Services Department 201 N Stone AV, Tucson, AZ 85701 (520) 724-9623 Nicholas.Jordan@Pima.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/19/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |