Permit Number: DP19-0051
Parcel: 13824083A

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP19-0051
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/24/2019 SBEASLE1 START PLANS SUBMITTED Completed
06/27/2019 MASHFOR1 COT NON-DSD FIRE Approved Please provide the Fire Sprinkler deferred submittal to TFD.
07/16/2019 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
PDSD Zoning Review Section

PROJECT: S & R Cabinet Builders - Industrial Use Group / General Manufacturing
Development Package (1st Review) - 6721 S. Renaissance Drive
DP19-0051 - I-1 Zoning

TRANSMITTAL DATE: July 16, 2019
DUE DATE: July 23, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is February 27, 2020.


***Please address the "Follow up Comments". The previous comments have been left as reference for the reviewer and applicant.


1. Follow up to Previous Comment 5: the required three foot from the back of the radius to the front of the dumpster enclosure was not provided as required by the standard. The trash enclosure must be set back from the end of the radius a minimum of three feet. Revise as required.

2-06.4.9.H.5 - If utilizing parking area access lanes (PAALs), they shall be designed in accordance with Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.

Previous Comment 5: Per UDC Article 7.4.6.F.4.c A minimum distance of three (feet must be provided between the back of spur and any wall, screen, or other obstruction over six inches in height. That said show the required 3' between the trash enclosure and the backup spur.


2. Follow up to Previous Comment 6: The previous comment was not addressed as required. The minimum width of the pedestrian refuge area is four feet. Per the plan only a three foot pedestrian refuge areas has been provided. Draw the four foot pedestrian refuge area as requested per the previous comment.


2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual.

Previous Comment 6: Per TSM Section 7-01.4.1.B A sidewalk is required adjacent and parallel to any access lane or PAAL on the side where buildings are located. Zoning acknowledges that TSM Section 7-01.3.B.2 allows for refuge areas in areas where public access is not allowed but a minimum 4' refuge area must be provided. That said provide a 4'-0" wide refuge area along the south side of the future building.

If you have any questions about this transmittal, Contact David Rivera on Tuesday, or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
07/22/2019 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL
SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS
4.1 Identification and Descriptive Data

All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.

Ensure that all Zoning comments and concerns are addressed.

Page index on Sheet 7 is obscuring verbiage on the bottom of page.

Additional comments may apply
07/24/2019 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP19-0051

1) Sheet L-5. The Water Harvesting Infiltration areas dont mirror the Basin list for volume and surface area as shown on the drainage report. Please double check wall water harvesting/retention basins in both the drainage report and plan set and verify the specifications match

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
07/25/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
The reviews have been completed and a resubmittal is required.
Permit/Activity Number: DP19-0051
Description: SITE/GRADING - S & R Cabinetry, manufacturing and future building.
Project Manager: Andrew.Connor@TucsonAz.gov, (520) 837-4950

Fee Balance: $165.00 (see the Balance column in the image below).
NOTE: We now accept payments online (Visa, MC, Discover, American Express) - for some permits, but not all. You may still pay in person or send in a check. City staff cannot view your online payments. All data and transactions are securely encrypted.
Link to Online Payments:
https://www.tucsonaz.gov/pdsd/online-resources-fees-maps-records
1. There is no cost to the customer for using the online payment portal.
2. Not case-sensitive but a hyphen is needed, e.g.: dp19-0000
3. Simply type in your Permit Nbr. and press enter on your keyboard.
4. If any issues, try using the browser Internet Explorer.

Please pay the total fees at the permit counter (Mon-Fri, 8:00 AM to 2:00 PM) or mail a check (payable to City of Tucson – address is shown below). Include the Activity Number on your check.

For review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number.
(If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.)
Please name your 3rd submittal documents accordingly, for example: 3_Plan_Set.
Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, please include the Activity Number.
1) Comment Response Letter (listing your response to reviewer's comments)
2) Plan Set (all pages, full set)
3) Any other items requested by review staff
At resubmittal, the plans will enter another 20-working-day review cycle.
Thank you.
Sharon Beasley, Permit Specialist

City of Tucson
Planning and Development Services
Attn: Permit Counter/Payments
201 N. Stone Avenue, First Floor
Tucson, AZ 85701
08/06/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed Comment made in error - the BWV note is on the drawings. [The revised first floor elevation for the building (2473.33') is still less than 12" above the rim elevation of the next upstream manhole. Provide a note on the plans requiring the installation of a backwater valve when future plumbing activities take place.] [Initial comment: The rim elevation of the next upstream sanitary manhole (2473.35') is higher than the proposed first floor elevation of the proposed office and manufacturing building (2473.00'). Provide a note on the plans requiring the installation of a backwater valve when future plumbing activities take place. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson.]

Final Status

Task End Date Reviewer's Name Type of Review Description
07/25/2019 SBEASLE1 OUT TO CUSTOMER Completed