Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: DP19-0051
Parcel: 13824083A

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP19-0051
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/19/2019 SBEASLE1 START PLANS SUBMITTED Completed
03/20/2019 MASHFOR1 COT NON-DSD FIRE Reqs Change Fire sprinklers will be required for this project. This is a proposed 14,000 sqft prefabricated building (F-1).

International Fire Code - 903.2.4 Group F-1 A automatic fire ssprinkler system shall be provided throughout all buildings containing a Group F-1 where conditions 1 & 4 have been met for Fire Sprinklers. Please make the required change on the plan set.
04/10/2019 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL

SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS

4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.
Clearly identify correct property lines and Right of Way's on the landscape plans.

The Development Package will contain the following identification:

Any relevant case numbers for reviews or modifications that affect the site.

Add case DP19-0051 in the lower right corner of sheet:

4.2 Proposed Landscape and Screening Improvements
The following information must be provided on the plans
Screening

a. Location of screening elements;
b. Height of screening material and reference point for measurement;
c. Nature of screening material (e.g., permanent or temporary as in phased development); and,
d. Type of screening material (e.g., masonry wall, wood fence, species of plant material).

Indicated screening elements on landscape plan.

Ensure that all Zoning and Engineering comments and concerns are addressed.


Additional comments may apply
04/12/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Revise the site drawing to show the location and size of both the water meter and the reduced pressure backflow preventer assembly. Reference Section 107.2.13, IBC 2012.
2. The rim elevation of the next upstream sanitary manhole (2473.35') is higher than the proposed first floor elevation of the proposed office and manufacturing building (2473.00'). Provide a note on the plans requiring the installation of a backwater valve when future plumbing activities take place. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson.
04/19/2019 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: S & R Cabinetry & Builders
Development Package (1st Review)
DP19-0051

TRANSMITTAL DATE: April 19, 2019

DUE DATE: April 17, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is March 17, 2020.

CONTENT REQUIREMENTS

1. 2-06.4.3 - The provided case number, DP19-051, on sheets 1-10 & 12, 13 & 15 should be revised to read DP19-0051.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

2. 2-06.4.7.A.4 - Sheet 1 General Note 5 should list the use as "GENERAL MANUFACTURING SUBJECT TO USE SPECIFIC STANDARDS 4.9.5.C.2, .6, .7, & .8 and 4.9.13.Q".

3. 2-06.4.7.A.6 - This project is located within the Airport Avigation Easement and Disclosure Area and may require review by Scott Robidoux Airport Planner. Contact Scott at srobidoux@flytucson.com.

4. 2-06.4.7.A.6 - Sheet 1 Remove General Notes 7 & 8 as this parcel does not boarder on an MS&R.

2-06.4.7.A.8 - For development package documents provide:

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

5. 2-06.4.9.H.5 - Per UDC Article 7.4.6.F.4.c A minimum distance of three (feet must be provided between the back of spur and any wall, screen, or other obstruction over six inches in height. That said show the required 3' between the trash enclosure and the backup spur.

6. 2-06.4.9.R - Per TSM Section 7-01.4.1.B A sidewalk is required adjacent and parallel to any access lane or PAAL on the side where buildings are located. Zoning acknowledges that TSM Section 7-01.3.B.2 allow for refuge areas in areas where public access is not allowed but a minimum 4' refuge area must be provided. That said provide a 4'-0" wide refuge area along the south side of the future building.

7. 2-06.4.9.W - Show the proposed locations of the signs. Also provide a note on the plans stating "ALL SIGNAGE REQUIRES SEPARATE PERMIT".

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
04/19/2019 SSHIELD1 ZONING HC REVIEW Approved
04/29/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
The reviews have been completed and a resubmittal is required.
Activity Number: DP19-0051
Project Description: SITE/GRADING - S & R Cabinetry, manufacturing and future building.
To view review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number. (If new comments aren't shown yet, check back later as data flows to PRO periodically throughout the day.)
After all corrections are made, name your 2nd submittal documents accordingly, for example: 2_Plan_Set.
Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, include the Activity Number.
1) Comment Response Letter (lists changes made to the Plan and to which reviewer comments you are responding)
2) Corrected Plan Set (all pages, full set)
3) Items requested by review staff
After resubmittal, the plans will re-enter the standard 20-working-day review cycle. The fee balance is $0 (zero).
Project Manager’s email: Andrew.Connor@TucsonAz.gov, phone: (520) 837-4950. Thank you.
Sharon Beasley

City of Tucson
Planning and Development Services
Attn: Permit Counter
201 N. Stone Avenue, First Floor
Tucson, AZ 85701
04/29/2019 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP19-0051

1) City of Tucson (COT) Stormwater Detention/Retention Manual, Section 2.2, requires threshold retention for all commercial or industrial developments larger than one acre in size. Per the supplied drainage statement detention requirements may be waived because the site discharges directly into the Santa Cruz River. Threshold retention requirements remain. Show how this is being met
2) Provide a pedestrian circulation path in accordance with City of Tucson (COT) Technical Standards Manual (TSM) section 7-01, including a connection to the proposed trash enclosure and the proposed storage building
3) Sheet C-3 detail 10. Remove note saying that detectable warnings are only required at transportation plat forms. Detectable warnings are required at all curb access ramps, not just those used for transportation platforms
4) ensure that roof drains scupper underneath sidewalks. Reference City of Tucson Technical Standards Manual (TSM) section 7-01.4.1.E
5) Sheet G-1. The drainage area is stated as being only 6450 sq ft. Clarify if this is accurate?

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007

Final Status

Task End Date Reviewer's Name Type of Review Description
04/29/2019 SBEASLE1 OUT TO CUSTOMER Completed