Permit Number: DP19-0018
Parcel: 117131640

Address:
141 S STONE AV

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP19-0018
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/25/2019 SBEASLE1 START PLANS SUBMITTED Completed
01/25/2019 SBEASLE1 OTHER AGENCIES U. S. POST OFFICE Passed This agency is being notified for their information only. No response is required.
01/25/2019 SBEASLE1 PIMA COUNTY PAG - PIMA ASSN OF GOVTS Passed
01/25/2019 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Passed This agency is being notified for their information only. A response is not required.
01/25/2019 SBEASLE1 UTILITIES SOUTHWEST GAS Passed This agency is being notified for their information only. A response is not required.
01/30/2019 SBEASLE1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Reqs Change January 29, 2019
RE: DP19-0018 Hampton Inn-Home2 / 1st Submittal, Received January 25, 2019

Dear Ms. Beasley,
Thank you for the opportunity to comment on DP19-0018, Hampton Inn-Home2; 1st Submittal, a development package application for an approximately 0.82 acre site, located northeast of the intersection of South Stone Avenue and East Corral Street. The property is zoned Commercial 3 (C-3), with the proposed development being a hotel.
This site is within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace.
The Tucson Airport Authority conditionally approves the subject request contingent upon the following condition of approval, as noted below. This condition shall be identified in the general notes of the revised development plan.

Condition of approval:
1. “According to the FAA Notice Criteria Tool, this project is located in proximity to a navigation facility and could impact navigation signal reception. The applicant shall file Form 7460 with the FAA at least 45 days before construction activities begin for the project. It is highly recommended that the applicant file earlier than 45 days to provide the applicant with sufficient time to respond to any concerns which are identified by the FAA. Any cranes used which are used must also be identified with Form 7460. Please file Form 7460 at https://oeaaa.faa.gov/oeaaa/external/portal.jsp”
Although this project does not propose a change in plan designation or zoning the Tucson Airport Authority highly recommends the City of Tucson consider requiring the applicant to add the following note into the general notes of the revised development plans. This project is located approximately 6 miles north of Tucson International Airport and is within FAA traffic pattern airspace, an area which would be subject to aircraft overflight and noise due to being in close proximity to Tucson International Airport.
The proposed note would provide a means of assuring that future owners and tenants of the property are aware they are in proximity an airport and further assures the continued right of the City of Tucson, Tucson Airport Authority, and all persons lawfully utilizing the Tucson International Airport the right to utilize the airspace above or near the property. This would be accomplished through requiring the property owner to record the Avigation Easement. The Tucson Airport Authority believes the proposed note helps to support the City of Tucson Airport Environs Overlay Zone and supports Plan Tucson – Regional and Global Positioning policy 4 (RG-4).
1. "That prior to the City's approval of any construction permit for a permanent building, the property owner shall record the Avigation Easement which discloses the existence, and operational characteristics of the Tucson International Airport to future owners or tenants of the property and further conveys the right to the public to lawfully use the airspace above the property. The Avigation Easement shall be recorded in a manner with the Pima County recorder which shall document it as having title liability. The content of such documents shall be according to the form and instructions provided."
The current property owner or person authorized to sign on behalf of the current property owner shall complete, sign, and record the Avigation Easement. Please record the Avigation Easement with the Pima County Recorder’s Office. Once the Avigation Easement is recorded please send a complete copy of the recorded easement document to Tucson Airport Authority by either email (send to srobidoux@flytucson.com) or to the mailing address provided below.
Scott Robidoux
Senior Airport Planner
Tucson Airport Authority
7250 South Tucson Boulevard
Suite 300
Tucson, AZ 85756

Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811.

Respectfully,
Scott Robidoux, Senior Airport Planner
02/05/2019 JOE LINVILLE COT NON-DSD LANDSCAPE Reqs Change Here are my comments:
1. Very good first submittal.
2. Will let Eng Staff comment on paving changes in Stone Ave.
3. Trees on Stone are fine with parking, but I am concerned about the area that bumps out. Is there a bike lane? Where is the travel lane edge?
4. Very concerned about tree planting on Corral St. This is very tight to the street and building.

Gary Wittwer, Landscape Architect
Gary.Wittwer@TucsonAz.gov
02/13/2019 SBEASLE1 PIMA COUNTY ADDRESSING Reqs Change **PDF attachment can be viewed on PRO in the "Documents" section**

The Addressing review of DP19-0018 for Hampton Inn / Home2 Suites is being Returned for Corrections by Pima County Addressing.
The attached pdf contains Addressing’s comments. Please let me know if you have any questions. Thank you,

Robin Freiman, Addressing Official
Pima County Development Services Department
201 N Stone AV – 4th Floor, Tucson, AZ 85701
(520) 724-7570
02/13/2019 MARTIN BROWN COT NON-DSD FIRE Reqs Change Please review Appendix D, section D105 of the 2018 International Fire Code and clearly indicate on plans how aerial access will be achieved.
02/15/2019 SBEASLE1 COT NON-DSD REAL ESTATE Reqs Change We have the following requests so that we can further review the plans.
1). Submit a legal description for the public access along Ochoa Street to the front porte cochere; this would be for a public access agreement.
2). If there are any building overhangs or signage that extend into the Right OF Way, we will need a new site amenity description; this would be for an aerial easement.
3). Any clarification on what improvements would be placed on the Corral Street and Stone Avenue Right Of Ways. From the submitted plans, it appears there will be landscaping, planters, and other site amenities to take into consideration for pedestrian easements.

Sincerely,
Thomas Kral, MAI, SRA
Real Estate Division
City of Tucson201 N. Stone Ave 6th Floor
Tucson, Arizona 85701
(P) 520.837.6708
(F) 520.791.5902
Thomas.Kral@tucsonaz.gov
02/19/2019 SBEASLE1 COT NON-DSD PARKS & RECREATION Approved No existing or proposed Tucson Parks and Recreation facilities are affected by this development.

Howard B. Dutt, RLA, Landscape Architect
Tucson Parks & Recreation
(520) 837-8040
Howard.Dutt@tucsonaz.gov
02/21/2019 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved 02/21/19 email from Tom Martinez, TMartinez@azdot.gov:
Regional Traffic Engineering has no comments on this submittal and supports its acceptance. The location of the development will have no impacts to any ADOT facilities.
Thank you.
02/22/2019 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
02/25/2019 NROSS1 ZONING HC REVIEW Reqs Change See zoning comments
02/25/2019 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Passed
02/25/2019 NICHOLAS ROSS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Nick Ross
Lead Planner

PROJECT: Hampton Inn/Home2 Suites
Development Package (1st Review)
DP19-0018

TRANSMITTAL DATE: February 25, 2019

DUE DATE: February 25, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is February 25, 2019.


1. 2-06.4.7.A.6.a - List additional applications and overlays, by case number (if applicable), in lower right corner of each sheet. As a general note provide the type of application processed or overlays applicable, a statement that the project meets the criteria/conditions of the additional application or overlay, the case number, date of approval, what was approved, and the conditions of approval, if any.

Comment: Provide appropriate IID information on the plans

2. 2-06.4.7.A.6.b - If there is more than one lot within the site, the note should specify which lots are affected by the additional applications or overlay zones.

Comment: See Comment 3

2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

3. 2-06.4.9.E - Proposed land splits or existing lot lines shall be drawn on the plan with dimensions and the identification number and approximate square footage of each lot. Land splits require a separate permit and review.

Comment: Site is made up of several parcels, lot combo will be required.

4. 2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.

Comment: The number of required parking spaces based on 1 space per rental unit + 1 space per 300sf gfa of conference, restaurant, retail, bar and banquet is 215. Total number provided 139. A parking reduction can be requested through the IID process, however please provide detail on gfa of conference, restaurant, retail, bar and banquet areas.

5. 2-06.4.9.L - All proposed easements (utility, sewer, drainage, access, etc.) are to be dimensioned and labeled as to their purposes and whether they will be public or private. The easements may have to be recorded and the recordation information added to the development package prior to approval.

Comment: Provide recordation information for all easements on site.

6. 2-06.4.9.O - All applicable building setback lines, such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown.

Comment: Building does not meet 79' required MS&R setback or the 118.5' setback adjacent to the R-2 zone on the northeast side of the site. These setbacks can be reduced to zero through IID process.

7. 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s).

Comment: Provide specific use within the footprint of the building.

8. 2-06.4.9.T - Show refuse collection areas, including locations of dumpsters, screening location and materials, and vehicle maneuverability, fully dimensioned, and access route. If dumpster service is not proposed, indicate type of service. For specific information on refuse collection, refer to Section 8-01.0.0, Solid Waste and Recycle Disposal, Collection, and Storage, of the Technical Standards Manual. Refuse collection on all projects shall be designed based on that section, even if collection is to be contracted to a private firm.

Comment: Indicate location of the trash compactor and 6-cubic-yard recycling bin on the site plan.

9. 2-06.4.9.W - Indicate the locations and types of proposed signs (wall, free-standing, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. Indicate if there are any existing billboards on site. Compliance to the Sign Code, Chapter 3 of the Tucson Code, is required.


If you have any questions about this transmittal, please contact me at Nicholas.Ross@tucsonaz.gov or (520) 837-4029.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
02/25/2019 ZELIN CANCHOLA COT NON-DSD TRAFFIC Reqs Change February 25, 2019
ACTIVITY NUMBER: DP19-0018
PROJECT NAME: Hampton Inn
PROJECT ADDRESS: 141 S Stone Ave
PROJECT REVIEWER: Zelin Canchola TDOT

Resubmittal Required: The following items must be revised and added to the Development package.

1. Provide east west pedestrian access along E Ochoa Street. Include standard pedestrian ramps. Proposed new public access easement will be acceptable however east west pedestrian access will need to be maintained.

2. No pavers on new sidewalk area, new colored concrete acceptable. Along Ochoa Street.

3. Show new pedestrian ramps at north east corner of Stone and Corral Street.

4. Close existing driveway at proposed new electrical transformer along Corral Street.

If you have any questions, I can be reached at 520 837 6659 or zelin.canchola@tucsonaz.gov
02/27/2019 SBEASLE1 COT NON-DSD ENVIRONMENTAL SERVICES Approved Environmental & General Services has completed our review of the Development Package for the proposed Hampton Inn - Home 2 project at 141 S. Stone Avenue in Tucson.
The waste generation calculations were reviewed and found to be correct. The applicant is proposing to install a stationary compactor to reduce the volume of both refuse and recycling materials by approximately 75 percent. The stationary compactor will be housed in a trash located room near the southwest corner of the building. The filled refuse and recycling containers from the stationary compactor will be rolled out of the trash room to E. Corral Street for servicing. Currently there are overhead electric lines on the north side of E. Corral Street. Cypress Civil Development has stated that as part of the project development, that the overhead electric lines would be removed and underground electric service would be provided.
Based on this review, Environmental & General Services approves the proposed solid waste management plans for the proposed Hampton Inn - Home 2 project.
Please let me know if there are any questions concerning this review. Thanks.

Tom Ryan, P. E.
City of Tucson - Environmental & General Services Dept.
03/04/2019 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. A keynote along Ochoa indicates a new tree grate per the landscape plans. The landscape plans don't indicate a planting at this location. Provide the correct keynote.
2. The solid waste calculations address the minimum volume required for the number of living units. Ensure any additional uses are accounted for in the calculation.
3. Clearly show roof drainage to demonstrate that the sidewalks will be kept flood free for up to a 10-year event.
03/05/2019 KMANNIN1 DESIGN PROFESSIONAL REVIEW Reqs Change Project currently going through IID design review. Further Design Review is required, folder will be denied until the project is complete. Please continue to include the Design Professional Folder.
03/05/2019 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL
SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS
4.1 Identification and Descriptive Data
Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.
List additional applications and overlays, by case number (if applicable), in lower right corner of each sheet. As a general note provide the type of application processed or overlays applicable, a statement that the project meets the criteria/conditions of the additional application or overlay, the case number, date of approval, what was approved, and the conditions of approval, if any.
Provide appropriate IID information on the plans.
Ensure that all Zoning and Engineering comments and concerns are addressed.
03/05/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
The reviews are completed and a resubmittal is required.
Activity Number: DP19-0018
Project Description: SITE/GRADING/IID - Hampton Inn/Home2 Suites
To see review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number. (If new comments aren't shown yet, check back later as data flows to PRO periodically throughout the day.)
Prepare a Comment Response Letter detailing changes to the plan and which review comments are being addressed. After the necessary corrections have been made, submit the following three items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd.
Enter the Activity Number in the Project Description field and name the file as directed, for example, a 2nd submittal: 2_Plan_Set.pdf. The plans will then re-enter a 20-working-day review cycle.
1) Comment Response Letter
2) Corrected plan set with all documents
3) Items requested by review staff
The fee balance is $0 (zero).
Nicholas Ross, copied, is the Project Manager to contact with any questions, email: Nicholas.Ross@TucsonAz.gov or phone: (520) 837-4029. Thank you.

Sharon Beasley
City of Tucson
Planning and Development Services
201 N. Stone Avenue, First Floor
Tucson, AZ 85701

Final Status

Task End Date Reviewer's Name Type of Review Description
03/05/2019 SBEASLE1 OUT TO CUSTOMER Completed