Review Status: Completed
Review Details: REVISION - - 1ST
Permit Number - DP19-0014
Review Name: REVISION - - 1ST
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/09/2021 | SBEASLE1 | ENGINEERING | REVIEW | Approved | Approved by Loren Makus, 07/09/21 (during the recent OK to Submit). |
| 08/03/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | The revised building FFE’s and manhole rim elevations have resulted in changes to the buildings requiring backwater valves. Buildings 1 and 2 currently are shown with backwater valves but buildings 3, 7, 8, and 9 require the addition of backwater valves. Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole in the public sewer or private sewer collection system, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson. |
| 08/05/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 08/10/2021 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Provide the type of construction for each building. Provide the fire flow data for the hydrants from Tucson Water Questions: Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 |
| 08/11/2021 | AWARNER1 | LANDSCAPE | REVIEW | Approved | |
| 08/20/2021 | SBEASLE1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | Email from: COTDSDPermits To: Jeff Stanley Fri 8/20/2021 10:28 AM REVISION Returned for Corrections: DP19-0014 DESCRIPTION: SITE/GRADING/SWPPP - Lot 42 Brown/Rita Ranch. 9013 E OLD VAIL RD Revision fee balance: $0 (zero) Thank you for the payment. INCLUDE IN YOUR RESUBMITTAL 1) Comment Response Letter (your response to the reviewer's Requires Change comments) 2) Plan Set pages/sheets for revision 3) Any other documents requested by review staff FILEDROP https://docs.tucsonaz.gov/Forms/tucsonpermitapp (Select "Existing Application", then enter permit number) SEE REVIEW COMMENTS and documents on PRO: www.tucsonaz.gov/pro (If information is not available, check back later after data transfers to PRO.) - Home page, Activity Search, enter the Activity/Permit Number - Permits - click on blue tab and you will see different sections - Reviews section - click on REVIEW DETAILS - Documents section - click on VIEW Thank you. Sharon Beasley, Permit Specialist City of Tucson, Planning and Development Services Email for Development Pkgs: COTDSDpermits@TucsonAz.gov (disregard the email response that will be sent automatically) Email for Building Permits: PDSDinquiries@TucsonAz.gov |