Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP19-0014
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/09/2019 | SBEASLE1 | START | PLANS SUBMITTED | Completed | |
| 05/28/2019 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 06/06/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 06/07/2019 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Section Manager PROJECT: Lot 42 Brown/Rita Ranch, 9013 E Old Vail Rd Development Package (2nd Review) DP19-0014 TRANSMITTAL DATE: June 7, 2019 DUE DATE: June 7, 2019 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is January 22, 2020. 1. This comment was not addressed correctly. Based on my count there are only 79 vehicle parking spaces on site, 67 standard and 12 accessible. Clarify. 2-06.4.9.H.5.a - On sheet 1, under General Note 27, list the use as "Industrial" only. Verify the number of spaces listed as provided is accurate. A count of spaces labeled on sheet 2 indicates 70 total spaces (including 12 accessible spaces) not 76 total as indicated. 2. This comment was not fully addressed. Per TSM Section 7-01.3.3.A & 7-01.4.1.A a sidewalk is required to from this project to all streets that the project has frontage. Provide a sidewalk from the site out to Rita Road. 2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual. At least one sidewalk is required to a project from each street on which the project has frontage. The sidewalk should be located to minimize any conflict with vehicular access to the project. Provide dimensions for all sidewalks provided on site, including existing sidewalks near buildings 1-4. Additionally, a sidewalk is required adjacent and parallel to any access lane or PAAL on the side where buildings are located. 3. 2-06.3.12 - The drawing index does not appear to be correct as the index only shows 10 sheets and the plan set has 11. 4. 2-06.4.2.D - The sheet number x of 10 is not correct as 11 sheets were provided in the plan set. 5. 2-06.4.9.G - As you are proposing a phased project, see sheet 2, provide calculations, vehicle & bicycle parking, etc., to indicate that each phase complies with all requirements as a separate entity. If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov or (520) 837-4966. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 06/07/2019 | SSHIELD1 | ZONING HC | REVIEW | Approved | |
| 06/10/2019 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Reqs Change | DP19-0014 1) Previous comment 4. Keynote 13 is missing being called out in several planters where roof drains are located. Please go through and double check placement of keynote 13 2) Engineering can perform an expedited review once the above comments have been addressed and a new work flow opened |
| 06/11/2019 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | PLAN RETURNED FOR CORRECTIONS NOTICE The reviews have been completed and a resubmittal is required. Activity Number: DP19-0014 Project Description: SITE/GRADING/SWPPP - Lot 42 Brown/Rita Ranch. For review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number. (If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.) After all corrections are made, please name your 3rd submittal documents accordingly, for example: 3_Plan_Set. Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd. In the Project Description field, please include the Activity Number. 1) Comment Response Letter (lists changes made to the Plan and which reviewer comments you are responding to) 2) Complete Plan Set (all pages, full set) 3) Any other items requested by review staff After resubmittal, the plans will re-enter the standard 20-working-day review cycle. The fee balance is $0 (zero). The Project Manager can be contacted at: Andrew.Connor@TucsonAz.gov, (520) 837-4950. Thank you. Sharon Beasley, Permit Technician City of Tucson Planning and Development Services Attn: Permit Counter 201 N. Stone Avenue, First Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/11/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |