Permit Number: DP18-0301
Parcel: 128100570

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP18-0301
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/06/2019 SBEASLE1 START PLANS SUBMITTED Completed
06/20/2019 DAVID RIVERA ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: David Rivera
Zoning Review Section

PROJECT: Administrative Office -
Development Package (1st Review) 301 or 251 S Williams Boulevard
DP18-0301 - PAD 1 Zoning

TRANSMITTAL DATE: June 20, 2019
DUE DATE: June 24, 2019

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is December 13, 2019.

*** Please address only the follow up comments. The previous comments have been left as reference for the zoning reviewer and applicant.

2-06.4.9.H.5 - If utilizing parking area access lanes (PAALs), they shall be designed in accordance with Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC.
1. Follow Up To Previous Comment 1: The previous comment asked that the applicant clearly demonstrate that UDC Article 7.4.6.F.2.a.(1) is addressed. The corrected plans do not demonstrate compliance. Please address as required.
Include a dimensioned x-section detail drawing of the PAALS where the canopies are proposed that demonstrate the 1-foot setback from the PAALs or add the 1-foot dimensions on sheet 3 of 24 / C3.0 where the canopies are proposed.
Previous Comment 1: Within the parking calculation you state "300 SPACES WILL BE COVERED PARKING). Clearly show the proposed parking covers on the plan. Clearly demonstrate that UDC Article 7.4.6.F.2.a.(1) is addressed.

2. The comment is minor and Zoning is willing to review the corrected DP over the counter once the corrected plans have been updated. It is your option to have zoning staff at the zoning counter review the final comment and access whether or not the corrections requested have been completed and approve the DP over the counter or email the zoning plans reviewer and request the review.

If you have any questions about this transmittal, please contact David Rivera 520-837-495 or David.Rivera@tucsonaz.gov or Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
06/21/2019 SBEASLE1 ZONING-DECISION LETTER REVIEW Reqs Change PLAN RETURNED FOR CORRECTIONS NOTICE
The reviews have been completed and a resubmittal is required.
The fee balance is $0 (zero).
Activity Number: DP18-0301
Project Description: E SITE/GRADING/SWPPP - Texas Instruments.
For review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number.
(If information isn't shown yet, check back later as data flows to PRO periodically throughout the day.)
After all corrections are made, please name your 4th submittal documents accordingly, for example: 4_Plan_Set.
Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd.
In the Project Description field, please include the Activity Number.
1) Comment Response Letter (states how all comments were addressed)
2) Complete Plan Set (all pages, full set)
3) Any other items requested by review staff
After resubmittal, the plans will re-enter the standard 20-working-day review cycle. The Project Manager can be contacted at: John.VanWinkle@TucsonAz.gov, (520) 837-5007
Thank you.

NOTE - Closed Thursday, July 4. We will reopen July 5 except for the following. Mechanical and Plumbing: Not available July 3, 4, and 5. Res. & Comm. Building: Not available July 4 and 5.


Sharon Beasley, Permit Technician

City of Tucson
Planning and Development Services
Attn: Permit Counter
201 N. Stone Avenue, First Floor
Tucson, AZ 85701
06/21/2019 JOHN VAN WINKLE ENGINEERING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
06/21/2019 SBEASLE1 OUT TO CUSTOMER Completed