Permit Number: DP18-0184
Parcel: 141390230

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP18-0184
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/01/2018 ALEXANDRA HINES START PLANS SUBMITTED Completed
08/09/2018 MARTIN BROWN FIRE REVIEW Reqs Change The main entrance to the complex should be a minimum of 20' wide, per section 503.2.1 of the 2018 International Fire Code.
Unable to determine from a PDF if a ladder truck can make the turn around at the island between the entrance and the club house. Please verify.
08/22/2018 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change UNIFIED DEVELOPMENT CODE
The landscape plan shall include the following:
4.1 Identification and Descriptive Data
A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.
The landscape plan will contain the following identification in the lower right corner of each sheet:
1. Cross-reference to:
a. Rezoning case;
b. Subdivision case;
c. Board of Adjustment case;
d. Design Development Option case;
e. Development Review Board (DRB) case; and/or,
f. Any other relevant case number for reviews or modifications that affect the site.
7.6. LANDSCAPING AND SCREENING
Minimum Width
Street landscape borders must be a minimum of ten feet wide as measured from the street property line.
Streetscape Landscape Border - Maximum Width
In situations where the street landscape border is wider than the minimum ten foot standard, the landscape border width needs to be determined for the purposes of calculating the 50% vegetative coverage standard. The width is that area between the required screen and the property line, unless there is permitted encroachment into the right-of-way as per this section.
Located on Site
Street landscape borders must be located entirely on site, except that, if approved by the City Engineer or designee.
Some landscaping appears to located in ROW.
Use of the Public Right-of-Way
Nonrequired landscaping may be placed in the public right-of-way, if the following standards are met:
1. The landscaping is approved by the City Engineer or designee and complies with the City Engineer's standards on construction, irrigation, location, and plant type;
2. All vegetation complies with the standards of Section 7.6.4, Landscaping Standards; and,
2. The landscaping does not interfere with the use of the sidewalk.

Provide the following Calculations
a. Square footage of the site;
b. Square footage of the oasis allowance area and calculation;
g. Square footage of all landscaped borders and calculation of the percentage of vegetative coverage, when applicable.
7.6.5. SCREENING STANDARDS
Screening for individual land uses and zones must be provided as determined in Table 7.6.4-1 and in addition to the required landscape borders. Screening is not required between similar uses in accordance with Table 7.6.4-1.
Identify Screening Elements Screening on Landscape Plan
a. Location of screening elements;
b. Height of screening material and reference point for measurement;
c. Nature of screening material (e.g., permanent or temporary as in phased development); and,
d. Type of screening material (e.g., masonry wall, wood fence, species of plant material).

Ensure that all Zoning and Engineering comments are addressed.
08/22/2018 NROSS1 ZONING HC REVIEW Approved
08/22/2018 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole in the public sewer or private sewer collection system, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. Floors discharging from above that reference point shall not discharge through the backwater valve. Reference: Section 715.1, IPC 2012, as amended by the City of Tucson.
08/22/2018 WILLDAN ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Nick Ross
Lead Planner

PROJECT: Encantada at Rita Ranch - 9300 E. Valencia Road
Development Package (1st Review) - Multi-Family Residential
DP18-0184 - C-2 Zoning

TRANSMITTAL DATE: August 16, 2018

DUE DATE: August 27, 2018

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is July 30, 2019.

2-06.3.0 FORMAT REQUIREMENTS

2-06.3.5 - Remove the Development Package PDSD approval stamp on all sheets. Reserve a three-inch by five-inch space in the lower right quadrant of each sheet for an approval stamp. The approval stamp will be applied electronically.

2-06.3.8 - Provide contour intervals on Grading Sheets under North Arrow.

2-06.3.11 - Incorrect sheet numbers labeled on Key Plan. Revise as required.

CONTENT REQUIREMENTS

2-06.4.1 - Is Developer also the owner of the property, if so add to the Developer Title on the coversheet. If not please add the owner's information as per this standard.


2-06.4.2.B - It appears there are multiple lots plus a block as part of the old subdivision. Have the lots and block been combined into on tax parcel. If so, please submit documents.

2-06.4.3 - Provide the development package case number, DP18-0184 , adjacent to the title block on all sheets.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

2-06.4.7.A.5 - Add a density calculation stating the number of residential units allowed and the proposed.

2-06.4.8.B - If applicable provide the information as noted by the standard.

2-06.4.9.F - Place all existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) on coversheet.

2-06.4.9.H.2 - Show future and existing sight visibility triangles. On a designated MS&R street, the sight visibility triangles are based on the MS&R cross-section.

2-06.4.9.H.5 - Clarify if parking spaces will include covered parking. If so parking structures must be 1 foot offset from PAAL.

2-06.4.9.H.5.a - Provide ADA parking calculation and total number provided based on 2%. The number van accessible spaces is also required. Also, Accessible Parking Sign must be dimensioned from top of sidewalk to the bottom of the van accessible sign.

2-06.4.9.H.5.d - All long term bicycle parking must inside apartments or in long term bicycle parking lockers (revise long term note under Minimum Number of Bicycle Spaces). Provide fully dimensioned bicycle parking detail drawings.

2-06.4.9.L - If applicable provide dimensions of any proposed easements.

2-06.4.9.V - For gang mailboxes indicate location to assure there are no conflicts with other requirements, such as pedestrian accessibility, utilities, and landscaping.

2-06.4.9.W - Indicate the locations and types of proposed signs (wall, free-standing, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. Indicate if there are any existing billboards on site. Compliance to the Sign Code, Chapter 3 of the Tucson Code, is required.


If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
08/23/2018 NROSS1 PIMA COUNTY ADDRESSING Reqs Change DP18-0184 Encantada at Rita Ranch / 1st Submittal is being Returned for Corrections by Pima County Addressing.

See pdf in PRO for Addressing’s comments.

Please let me know if you have any questions or if I may assist you further.

Warm Regards,



Robin Freiman

Addressing Official

Pima County Development Services Department

201 N Stone AV – 1st Floor
Tucson, AZ 85701

(520) 724-7570
08/24/2018 JOHN VAN WINKLE ENGINEERING REVIEW Reqs Change DP18-0184
1) Sheet 3. Accessible parking sign detail 2. Revise ground clearance to 7' from grade to lowest sign
2) Where applicable adjust positioning of trash enclosures so that when the swing gate is open, it does not interfere with the 24' wide PAAL
3) Per City of Tucson Stormwater Detention/Retention Manual section 3.4.2 provide a grade control marker for each proposed basin. On the plans please also provide the coordinates of the grade control markers so that they can be easily located in the future
4) A PIA will be required at time of construction with TDOT
5) Sheet 3, details A and B. Revise sidewalk width, currently shown as 5', to be a minimum of 6'. Reference City of Tucson Technical Standards Manual (TSM) section 10-01.4.1
6) At both the east and west entrances the sidewalk ramps on the east and west sides are separated by a median. Provide a median refuge area per Pima Association of Governments (PAG) standard detail 207. See following link. http://apps.pagnet.org/StandardSpecifications/Documents/Drawings/PAGStdDtl-207.pdf
7) Per section 1.4 of the Stormwater Detention/Retention Manual, threshold retention is required to retain at a minimum the volumetric difference between the developed and existing 5 year runoff.
8) Provide infiltration analysis to ensure that the proposed basin will drain within 12 hours.
9) Sheet 13. Basin Top is shown as 1916. Is this an elevation? If so it appears to be incorrect.
10) Per City of Tucson Standards for Drainage Design section 14.3, paragraph 4, provide a minimum of one 15' wide access ramp into the proposed basin.
11) Show how the proposed plan is in compliance with City of Tucson Unified Development Code (UDC) section 7.6.6.C. Particularly the grading of the vehicular use areas should be in such a manner that runoff is directed into landscaped areas. Curb cuts should be provided at optimal locations to allow runoff to enter landscaped areas. Available landscape area should be depressed up to 6" to maximize water harvesting.

John Van Winkle, P.E.
John.VanWinkle@tucsonaz.gov
520-837-5007
08/29/2018 ALEXANDRA HINES PIMA COUNTY WASTEWATER Approved Separate Submittal to Pima County Wastewater by P18WC00206 Capacity Letter and P18WS00064 Sewer Layout Approval.
08/29/2018 ALEXANDRA HINES ZONING-DECISION LETTER REVIEW Reqs Change Plan Returned for Corrections Notice: DP18-0184
This review has been completed and resubmittal is required. View the comments on www.tucsonaz.gov/pro and search by activity number. Prepare a Comment Response Letter which tells the reviewer what changes have been made to the plan and what comments are addressed. When you have made the necessary corrections to the plans, please resubmit the following items to PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd:1) Revised Plan Set2) All items requested by review staff3) All items needed to approve these plans
Please remember to name your files appropriately, for example: Example second submittal:2_plan_set.pdf2_comment_response _letter.pdf
Thank you,
Alexandra Hines

Final Status

Task End Date Reviewer's Name Type of Review Description
08/29/2018 AHINES2 OUT TO CUSTOMER Completed