Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP18-0182
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/02/2018 | ALEXANDRA HINES | START | PLANS SUBMITTED | Completed | |
| 11/21/2018 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera PDSD Zoning Review Section PROJECT: Family Dollar Store - Retail Use / General Merchandise Development Package (2nd Review) - 210 W. Irvington Road DP18-0182 - C-2 Zoning TRANSMITTAL DATE: November 21, 2018 DUE DATE: November 29 5, 2018 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is July 30, 2019. ***Address the Follow Up Comments only. The previous comments have been left as reference for the applicant to refer to from the previous review. 1. Follow Up To Previous Comment 6: The legal description was not added to all sheets as requested per the previous comment. Add the legal description in the title of sheets 3 -11. Previous Comment 6: The legal description was not added to all sheets as requested per the previous comment. Add the legal description in the title of sheets 10-12. 2. Follow Up To Previous Comment 17: Clarify if the if the lot combo has been completed. If it looks like it will take longer to get the lot combo completed than it does to get this DP approved you can request deferring submittal of the documentation for the lot combo to approval of the final building inspection. If the lot combo is in process and is soon to be completed provide the documents with the next submittal of the DP. Previous Comment 17: The previous comment is still applicable and will remain until the Pima County Tax Parcel Combo is completed. 3. Follow Up To Previous Comment 24: Review the bicycle design criteria UDC section 7.4.9. figure 7.4.9-C. The dimensions on the detail drawing for the short term facility at the proposed location do not allow for a clear 4 foot wide sidewalk area. There shall be a minimum of two feet from the outside edge of the rack towards outside edge of the sidewalk. Revise as required Add the detail drawing for the long term facility on DP sheet 2. Follow Up To Previous Comment 24: The location and type of long term bicycle facility could not be verified on the site plan sheet or details sheet. Add the dimension detail drawing for the long term facility and draw and label the location. If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 11/21/2018 | DAVID RIVERA | ZONING HC | REVIEW | Approved | |
| 11/26/2018 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | Unified Development Code ADMINISTRATIVE MANUAL SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS 4.1 Identification and Descriptive Data A. All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. Ensure that all Engineering and Zoning comments are addressed. |
| 11/27/2018 | SBEASLE1 | OTHER AGENCIES | TUCSON AIRPORT AUTHORITY | Approved | November 27, 2018 Alexandra Hines Lead Planner City of Tucson Public Works Buildings – 201 North Stone Avenue Tucson, AZ. 85701 RE: DP18-0182 Family Dollar / 3rd Submittal, Received November 2, 2018 Dear Ms. Hines, Thank you for the opportunity to comment on DP18-0182, Family Dollar; 3rd Submittal, a development package application for an approximately 0.81 acre site located northwest of the intersection of West Irvington Road and South 9th Avenue. The land use is commercial, with the proposed development being a retail store. This site is within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace. The Tucson Airport Authority is satisfied with the 3rd submittal of this project and has no additional comments to submit. Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811. Respectfully, Scott Robidoux, Senior Airport Planner cc file |
| 11/30/2018 | JOHN VAN WINKLE | ENGINEERING | REVIEW | Approved | |
| 12/03/2018 | SBEASLE1 | ZONING-DECISION LETTER | REVIEW | Reqs Change | 12/03/18 Plans Returned for Corrections (RFC) Notice: DP18-0182 Project Description: E SITE/GRADING/SWPPP - FAMILY DOLLAR The review has been completed and a resubmittal is required. To see review comments about the plans, visit PRO at www.tucsonaz.gov/PRO, then search by activity number. (If new comments aren't shown yet, please check back later as data flows to PRO at periodic intervals throughout the day.) Prepare a Comment Response Letter which tells the reviewers what changes have been made to the plan and what review comments are addressed. When you have made the necessary corrections to the plans, please submit the following items to PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd: 1) Comment Response Letter 2) Corrected plan set 3) Items requested by review staff The plans will then re-enter the 20 working day review cycle. Please type the activity number in the Project Description and name the files as described on the PDSD Filedrop web page. The current fee balance is $ 0 (zero). Nicholas Ross, copied, is the Project Manager to contact with any questions: 520-837-4029. Thank you. Sharon Beasley City of Tucson Planning and Development Svcs. Dept. 201 N. Stone Ave, 1st Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/03/2018 | SBEASLE1 | OUT TO CUSTOMER | Completed |