Permit Review Detail
Review Status: Completed
Review Details: REVISION - - 2ND
Permit Number - DP17-0007
Review Name: REVISION - - 2ND
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/13/2019 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 06/20/2019 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | It appears that a required screen wall is being placed off site. The following applies: ALL required screening must be provided on the developing property or a joint use agreement must be provided indicating that the adjacent wall may be used to meet the screening requirement. Provide a recorded joint use agreement before we can approve the plan and the recording information for the joint use agreement must be referenced on the plan (typically where they reference the existing wall). Verify that the adjoining wall complies with the height requirement as measured from the adjacent grade being developed. The requirement is measured from the use requiring the screening. A cross section should always be provided on the plan showing the adjacent grades and the measurement of the wall height. |
| 07/09/2019 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | FROM: David Rivera PDSD Zoning Review Section PROJECT: D17-0007 - Storacle Point Castro / Multifamily Development Revision 2 (1st Review) 2820 N. Castro Avenue - O-3 Zoning TRANSMITTAL DATE: July 9, 2019 DUE DATE: July 11, 2019 COMMENTS: Address zoning comments related to the revision letter. 01. COMMENT: Response to Revision # 1: It appears that a required screen wall has been placed on private property to the north. A cross access easement is required as well as a Joint use agreement for the wall. Recorded documents must be provided prior to zoning approval. 02. COMMENT: Response to Revision # 4: What is the purpose of a loading bay and ramp? Is this supposed to be for an ADA space, clarify. 03. COMMENT: Response to Revision # 5: The ADA space that was removed was the Van accessible space. One van accessible space is required and of the two remaining ADA spaces next to building one neither is designated as a van accessible space. Keep in mind that the van space and access aisle must be a minimum of 16 feet between the two. 04. COMMENT: Response to Revision # 6: The symbol used for the Mailbox shall be added to the legend on the cover sheet. 05. COMMENT: Response to Revision # 7: By relocating the sidewalk as noted in the revision note 7, the parking stall has been reduced to less than the required 18' stall. Zoning cannot approve the stall length without a DSMR approval. Contact Steve shields for confirmation that zoning could support a DSMR. 06. COMMENT: Response to Revision # 7: What is the purpose or use for the striped area next to the previous ADA parking space west of building 2? If you have any questions about this transmittal, Contact David Rivera on Tuesday or Wednesday at (520) 837-4957 or by email David.Rivera@tucsonaz.gov or contact Steve Shields any time during the week at (520) 837-4956 or email Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: |
| 07/09/2019 | DAVID RIVERA | HC SITE | REVIEW | Reqs Change | See zoning comments |
| 07/10/2019 | SBEASLE1 | ZONING-DECISION LETTER | WRITE DECISION LETTER | Reqs Change | REVISION PLAN RETURNED FOR CORRECTIONS NOTICE The reviews have been completed and a resubmittal is required. Fee Balance: $346.50 (see the Balance column in the image below). Prior to the completion of the next review, we require payment of the total fees (or the Review fees at a minimum). You may pay in person at the City of Tucson permit counter (Mon-Fri, 8:00 AM to 2:00 PM) or mail a check payable to the City of Tucson (see address below). Please write your Activity Number on the check stub. Activity Number: DP17-0007 Project Description: SITE/GRADING - Storacle Point Castro. To view review comments, visit PRO at www.tucsonaz.gov/PRO, then search by Activity Number. (If information isn't shown yet, check back later as data flows to PRO periodically throughout the day. After the corrections are made, please name your Revision #2, 2nd submittal documents accordingly, for example: REV-2_2_Plan_Set. Submit the following items to the PDSD Filedrop at https://www.tucsonaz.gov/file-upload-pdsd. In the Project Description field, please include the Activity Number. 1) Comment Response Letter 2) Plan Set (or sheets) 3) Any other items requested by review staff After resubmittal, the plans will again enter the standard 20-working-day review cycle. Thank you. Sharon Beasley, Permit Specialist City of Tucson Planning and Development Services Attn: Permit Counter/Payments 201 N. Stone Avenue, First Floor Tucson, AZ 85701 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/10/2019 | SBEASLE1 | OUT TO CUSTOMER | Completed |