Permit Review Detail
Review Status: Completed
Review Details: SITE and/or GRADING
Permit Number - DP16-0068
Review Name: SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/27/2016 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 05/13/2016 | SSHIELD1 | ADA | REVIEW | Passed | |
| 05/13/2016 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Principal Planner PROJECT: Dyson Medical Center Development Package (1st Review) DP16-0068 TRANSMITTAL DATE: May 13, 2016 DUE DATE: May 20, 2016 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is April 21, 2016. 1. 2-06.4.1 - Provide the name, mailing and email addresses, and phone number of the primary property owner of the site on the right half of the cover sheet. 2. 2-06.4.7.A.4 - Revise General Note 2 to include outpatient and the use specific standard 4.9.13.K. 3. 2-06.4.7.A.6.a - Provide a general note on the cover sheet stating "THIS PROJECT IS DESIGNED TO MEET THE OVERLAY ZONE(S) CRITERIA, UDC ARTICLE 5.4 MAJOR STREETS AND ROUTES SETBACK ZONE (MS&R)." 4. 2-06.4.9.H.5.d - Revise the bicycle detail to show the required 5' access aisle, see UDC Article 7.4.9.B.2.h and figure 7.4.9-C. 5. 2-06.4.9.R Demonstrate on the plan that the existing accessible vehicle parking spaces and access ramps meet the requirements of IBC Chapter 11 and the ICC A117.1-2009. Once the above comments have been address Zoning will provide and over-the-counter review. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 05/13/2016 | SSHIELD1 | H/C SITE | REVIEW | Approved | See Zoning comments |
| 05/18/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Revise the site drawing to include the following information: a. The location and size of water lines. b. The location of sanitary and storm sewers, including the pipe diameter and the invert and rim elevations of all manholes and cleanouts; along with the Pima County Wastewater Management Department (PCWMD) reference number. c. The points of connection to existing public sewers. d. Any existing or proposed utility easements e. The first floor elevation for the building Reference: City of Tucson Administrative Manual No. 2-06.0.0, Section 4.8 and Section 107.2.13, IBC 2012. |
| 05/19/2016 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 05/20/2016 | JOE LINVILLE | NPPO | REVIEW | Approved | |
| 05/20/2016 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/03/2016 | ARUIZ1 | OUT TO CUSTOMER | Completed |