Permit Number: DP16-0044
Parcel: 13705494B

Review Status: Completed

Review Details: REVISION - TENT PLAT & CORE RESUB

Permit Number - DP16-0044
Review Name: REVISION - TENT PLAT & CORE RESUB
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/24/2017 ALEXANDRA HINES START PLANS SUBMITTED Completed
07/26/2017 STEVE SHIELDS ZONING REVIEW Approved
07/26/2017 SSHIELD1 H/C SITE REVIEW Approved
08/02/2017 ALEXANDRA HINES PIMA COUNTY ADDRESSING Approved DP16-0044 IRVINGTON & I-19 2nd submittal of proposed 3rd revision to the Tentative Plat is Approved by Pima County Addressing.

Thank you,

Robin Freiman
Addressing Official
Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-7570
08/02/2017 ALEXANDRA HINES UTILITIES TUCSON ELECTRIC POWER Reqs Change 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702

July 27, 2017

WR# 6193702

DSD_CDRC@tucsonaz.gov
patricia.gehlen@tucsonaz.gov
reast@bourncompanies.com
jphunt@cypresscivil.com

Dear Mr. Hunt

SUBJECT: Irvington & I-19 Commercial Development
1050 W Irvington Rd
DP16-0044

Tucson Electric Power Company has reviewed and not approved the development plan. Please make corrections and resubmit for approval.

The development is ndicating that vegetation is proposed to be installed within TEP's existing 70' wide 138KV easement. No trees can be planted underneath the lines; furthermore, no trees that grow taller than 15' at maturity can be planted within the easement. The landscape plan does not reflect what was agreed upon with the developer.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans.

If easements are required, they will be secured by separate instrument. Your final plans should be sent to:
Tucson Electric Power Company
Attn: Rich Harrington
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8726

Should you have any technical questions, please call the area Designer, Josh Necas @ 917-8759.
Sincerely,
Beth Shelton
Elizabeth "Beth" Shelton
Admin Assistant
Design
08/15/2017 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Provide identification numbers for the private manholes. [Initial comment: Revise the "utility + easements" plans to include the identification numbers and rim elevations of the new private manholes for evaluation of the need for backwater valves. Reference: City of Tucson Administrative Manual, Section 2-06.4.8D, Section 107.2.1, IBC 2012, and Section 715.1, IPC 2012, as amended by the City of Tucson.]
2. The rim elevation of the manhole upstream of building 42 (2424.63') is less than 12" below the first floor elevation (2425.00'). Show the installation of a backwater valve for building 42 per Section 715.1, IPC 2012, as amended by the City of Tucson.
08/16/2017 KELLY LEE ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:
1) Two rolled sets of the plans
2) All approved documents submitted previously
3) A disk containing all items submitted
4) All items requested by review staff
5) All items needed to approve these plans

Final Status

Task End Date Reviewer's Name Type of Review Description
08/31/2017 KROBLES1 OUT TO CUSTOMER Completed