Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Permit Number - DP15-0191
Review Name: RESUBMITTAL - CDRC - TENTATIVE PLAT REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/05/2016 | MARTIN BROWN | COT NON-DSD | FIRE | Approv-Cond | ADDED CONDITION-COULD NOT FIND COMMENT ON DRAWINGS |
| 01/11/2016 | FDILLON1 | DESIGN PROFESSIONAL | REVIEW | Denied | This project requires an Architectural Variation Plan (AVP) per UDC Section 8.7.3.M. |
| 01/19/2016 | JANE DUARTE | COT NON-DSD | PARKS & RECREATION | Approv-Cond | All Parks and Recreation comments have been adequately addressed except for our comment #1 which states: 1) Note #17 on sheet 2 is incorrect and should be revised. According to the current Pima Regional Trails System Master Plan, there are two trails located on or adjacent to this property. The Esmond Station and the Atturbury Wash South Fork Greenways are located on this property... Revise Note #17 to cite the current COT/Pima County trail planning document as the "Pima Regional Trails System Master Plan" and to recognize the existence on that master plan of the Esmond Station and Atturbury Wash South Fork Greenways which are located on or adjacent to this site. The note should also state that these greenways are accommodated by the inclusion of Non-motorized Trail Easements on the plan for future trail extension by others. Howard B. Dutt, RLA Landscape Architect Tucson Parks & Recreation (520) 837-8040 Howard.Dutt@tucsonaz.gov |
| 01/20/2016 | BVIESTE1 | ENV SVCS | REVIEW | Approv-Cond | The Development Package has been reviewed on behalf of the Environmental Services Dept. and is conditionally approved pending the following comment: · Please correct the phasing labeling on Sheet 8 for Phase One and Two. If there are any questions, I can be reached at kperry@perryengineering.net |
| 01/20/2016 | MPADILL1 | COT NON-DSD | COMMUNITY PLANNING | Approv-Cond | Conditional approval subject to the following condition. Correct Development plan, remove reference to R-2 zone where ever noted. Sheet 2 of 25 makes reference to R-2 zone. Correct all necessary sheets by removing all references to R-2 zone. Site is zoned R-1. |
| 01/22/2016 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) All items requested by review staff 3) All items needed to approve these plans |
| 12/23/2015 | KROBLES1 | START | PLANS SUBMITTED | Completed | |
| 12/29/2015 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 12/29/2015 | ED ABRIGO | PIMA COUNTY | ASSESSOR | Approved | Office of the Pima County Assessor 115 N. Church Ave. Tucson, Arizona 85701 BILL STAPLES ASSESSOR TO: CDRC Office Subdivision Review City of Tucson (FAX# 791-5559) FROM: Janice Wagner GIS Cartographer Pima County Assessor's Office DATE: December 28, 2015 RE: Assessor's Review and Comments Regarding: FINAL PLAT MOUNTAIN VAIL ESTATES, PART G S15-051 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * X Plat meets Assessor's Office requirements. _______ Plat does not meet Assessor's Office requirements. COMMENTS: |
| 12/29/2015 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Approved | Traffic impact analysis to determine traffic signal requirement will be made seperate from Development Plan Process. Zelin Canchola TDOT |
| 12/29/2015 | JENNIFER STEPHENS | PIMA COUNTY | ADDRESSING | Reqs Change | See additional documents in PRO. Request for Corrections—please see attached plans with Addressing comments attached as sticky notes. |
| 12/30/2015 | PAUL BAUGHMAN | ENGINEERING | REVIEW | Reqs Change | DATE: January 4, 2016 DUE DATE: January 25, 2016 SUBJECT: Mountain Vail Estates, Part G TO: Warren D. Thompson, PE LOCATION: 11311 E Mary Ann Cleveland REVIEWERS: Paul Baughman, PE, CFM ACTIVITY: DP15-0191 SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed 2nd submittal of Development Plan Package. The following items need to be addressed: 1) Per AM 2-06.4.8H and AM 2-06.4.9N2 and previous 1st submittal comment please show drainage gradients of streets on the site plan. Per a check against the originally approved drainage report, submitted electronically with this 2nd submittal, a 0.58% and 0.57% slope in front of lots 86 - 89 do not match Figure 4 of the developed conditions watershed in the drainage report. Please update the plan or the drainage report. 2) Per AM 2-06.4.8I and AM 2-06.4.9O and 1st submittal comment please show where locally regulated floodplain limits will be located based on developed conditions. Please also show where FEMA floodplain limits will be based on LOMR submittal. All of the existing and developed conditions FEMA and locally regulated floodplain line work should be reflected in the legend. The legend does not reflect the line work used to show the developed conditions floodplain based on the LOMR. 3) Please initiate process with City during review of LOMR, if required by FEMA, to set up any agreements that may be required based on CFR 44 Sec 65.2 and 65.10 maintenance requirements. This will be reviewed with the LOMR submittal. If you have any comments questions or wish to discuss new information, please call or email me at 520-837-5007 or paul.baughman@tucsonaz.gov. |
| 12/30/2015 | BVIESTE1 | PIMA COUNTY | WASTEWATER | Approved | Pima County Regional Wastewater Reclamation Department Jackson Jenkins Director 201 N. Stone Ave., 8th Floor Tucson, Arizona 85701-1207 PH: (520) 740-6500 FAX: (520) 620-0135 December 29, 2015 To: Warren Thompson, P.E. Stantec Consulting Services, Inc Thru: Patricia Gehlen City of Tucson Development Services ____________________________________ From: Tom Porter, P.E., PCRWRD (520) 724-6719 Subject: Mountain Vail Estates Part G Lots 1-95 Tentative Plat - 2st submittal P15WS00043 (DP15-0191) The Pima County Regional Wastewater Reclamation Department (PCRWRD) has reviewed the proposed sewer design for the above-referenced project. The Pima County Regional Wastewater Reclamation Department approves the above referenced submittal of the Preliminary Sewer Layout (PSL), based upon PCRWRD Engineering Design Standards (EDS) 2012. If you have any questions regarding this matter please contact me at your convenience. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/22/2016 | AROMERO4 | OUT TO CUSTOMER | Completed |
| 01/22/2016 | PGEHLEN1 | REJECT SHELF | Completed |