Review Date Reviewer's Name Type of Review Description Status Comments
03/14/2016 PAUL BAUGHMAN ENGINEERING REVIEW Reqs Change DATE: March 16, 2016
DUE DATE: April 4, 2016
SUBJECT: Storage Addition for Protire
TO: William John Taylor
LOCATION: 4937 E Speedway Blvd
REVIEWERS: Paul Baughman, PE, CFM
ACTIVITY: DP15-0021
SUMMARY: Engineering Division of Planning and Development Services Department has received and reviewed the proposed Development Plan Package. The following items need to be addressed:
1) Per TSM 10-01.2.7A and previous comment number 1 please show wheelchair ramps along south frontage. Include a 25' radius curb return per Figure 6 and TSM 10-01.3.2C.
2) Per TSM 7-01.4.3E and previous comment number 2 please show how all 10 year drainage, including roof drainage for the new building addition is conveyed under the pedestrian way/sidewalk. Per AM 2-06.4.8F please show where roof drainage downspouts are located with flow arrows per the Tucson Drainage Standards Manual Section 5.2, item 3.
3) Per TSM 8-01.8.0A and previous comment number 3 please provide a Waste stream calculation to determine whether a 95 gallon APC is sufficient or whether a metal container must be used. If a metal container must be used please show layout per TSM Section 8 on next submittal. Per AM 2-06.4.9T show refuse collection areas.
4) Per TSM 4-01.2.1A6 and previous comment number 4 please show pavement sloping towards recessed planting areas.
5) Per AM 2-06.4.7A8c and previous comment number 5 please show the square footage of new pavement for vehicle use area expansion (ie. Parking lot area).
6) Per AM 2-06.4.8B and AM 2-06.4.9L and previous comment number 6 please call out any easements the OHE line work may fall into if applicable.
7) Per AM 2-06.4.8D and previous comment number 7 please show Sewer, water, gas, electric, storm drain and phone lines within 50 feet of the site, including all of the adjacent streets and 50 feet on the other side of the street.
8) Per AM 2-06.4.8E1 and AM 2-06.4.9N4 and previous comment number 8 please provide spot grades and contours on and adjacent to the site to show general existing and proposed drainage patterns. These spot grades and contours must clearly demonstrate that drainage patterns do not change per Section 2.3.1.5F of the Tucson Drainage Standards Manual.
9) Per AM 2-06.4.8G and previous comment number 9 please indicate whether the existing wall visible in google street view will be removed or retained.
10) Per AM 2-06.4.8H and previous comment number 10 please show the approximate direction and gradients of ground slope within 50 feet of the site.
11) Per AM 2-06.4.9H5d and previous comment number 12 please show all bicycle parking facilities fully dimensioned per UDC Section 7.4.9C2.
12) Per AM 2-06.4.9N and previous comment number 13 please show areas of detention/retention, proposed drainage solutions, such as origin, direction and destination of flow and location and type of drainage structures.
13) Per UDC Section 7.4.6F4 and figure 7.4.6-B and previous comment number 14 please dimension the backup spur and show that any obstruction over 6" in height is setback at least 3' from the edge of the backup spur. There is concern that the plans calls for a tree to be planted in this 3 foot setback area. Please make appropriate adjustments.
14) Per UDC Section 7.4.6H1 and previous comment number 15 please show barrier such as curbing to stop cars from damaging the wall or landscaping on the north side when they utilize the back up spur.
15) The seal date for the registrant has not been updated since the first comment letter was issued and changes were made. Please update the seal date or cloud changes as appropriate under a new seal if changes are made to the registrant's drawings.
If you have any comments questions or wish to discuss new information, please call or email me at 520-837-5007 or paul.baughman@tucsonaz.gov.
03/30/2016 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change Comment not addressed. [Initial comment: Revise the site drawing to include the following existing utility information:
a. The location and size of water lines and fire hydrants.
b. The location of public sanitary sewers, including the pipe diameter and the invert and rim elevations of all manholes and cleanouts; along with the Pima County Wastewater Management Department (PCWMD) reference number.
c. The point of connection to the existing public sewers.
d. The locations of gas lines, electric and telephone lines, poles, and communications cables, on-ground junction boxes, and street lights.
e. Any existing or proposed utility easements
f. The first floor elevation for the building addition
Reference: City of Tucson Administrative Manual, Section 2-06.4.8D and Section 107.2.1, IBC 2012.]
03/30/2016 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change ADMINISTRATIVE MANUAL SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS

Identification and Descriptive Data

All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan.


UNIFIED DEVELOPMENT CODE

ARTICLE 7: DEVELOPMENT STANDARDS

The following comments were not addressed from previous review.

Within a vehicular use area, one canopy tree is required for each four motor vehicle parking spaces or fraction thereof.

The canopy trees must be evenly distributed throughout the vehicular use area. Every parking space must be located within 40 feet of the trunk of a canopy tree (as measured from the center of the tree trunk). Additional trees are needed for parking area to the north.

Inorganic Ground Cover

Except as otherwise provided by this section, the area between the right-of-way line and sidewalk and the area between the sidewalk and the curb, if not covered with vegetation, must be covered with an appropriate inorganic ground cover, such as decomposed granite

Ensure that all Zoning and Engineering comments and concerns are addressed.

Additional comments may apply
04/01/2016 SSHIELD1 HC SITE REVIEW Reqs Change See Zoning Comments
04/01/2016 SSHIELD1 ADA REVIEW Passed
04/01/2016 STEVE SHIELDS ZONING REVIEW Reqs Change