Permit Review Detail
Review Status: Completed
Review Details: REVISION - TENT PLAT & CORE RESUB
Permit Number - DP14-0248
Review Name: REVISION - TENT PLAT & CORE RESUB
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/05/2016 | LBOJORQ1 | START | PLANS SUBMITTED | Completed | |
| 12/13/2016 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Principle Planner PROJECT: Old Vail Plaza Development Package (Revision 3) DP14-0248 TRANSMITTAL DATE: December 14, 2016 DUE DATE: December 19, 2016 COMMENT: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Sheet 1, "PROPOSED LOT & COMMON AREA BREAKDOWN", Lot 9 "MAXIMUM BUILDING AREA" does not match what is shown on sheet 10. 2. Sheet 1, "PROPOSED LOT & COMMON AREA BREAKDOWN", Lot 9 "REQUIRED PARKING" based on a total sq. ft. of 5,545/300 shouldn't the required parking be 18? 3. Sheet 1, "PROPOSED LOT & COMMON AREA BREAKDOWN", Lot 9 ""REQ. BIKE PARKING (SHORT-TERM)" based on a total sq. ft. of 5,545/300 shouldn't the required short-term bicycle parking be 3? Sheet 10 will need to be revised to reflect this requirement. 4. Sheet 1, "PROPOSED LOT & COMMON AREA BREAKDOWN", Lot 7 should this not reference food service as depicked on the "ACTUAL LOT & COMMON AREA BREAKDOWN". 5. Sheet 1, "ACTUAL LOT & COMMON AREA BREAKDOWN", Lot 9 "PARKING" based on a net minus 7 vehicle parking spaces shouldn't provided number be 41? Once this comment is addressed Zoning will provide an over-the-counter review. Call or email to schedule an appointment for this review. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 12/14/2016 | SSHIELD1 | H/C SITE | REVIEW | Passed | |
| 12/16/2016 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 12/19/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Completed | |
| 12/20/2016 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) All approved documents submitted previously 3) All items requested by review staff 4) All items needed to approve these plans |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/03/2017 | LBOJORQ1 | OUT TO CUSTOMER | Completed |