Permit Review Detail
Review Status: Completed
Review Details: REVISION - TENT PLAT & CORE RESUB
Permit Number - DP14-0248
Review Name: REVISION - TENT PLAT & CORE RESUB
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/26/2016 | AHINES2 | START | PLANS SUBMITTED | Completed | |
| 10/27/2016 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Principle Planner PROJECT: Old Vail Plaza Development Package (Revision 2) DP14-0248 TRANSMITTAL DATE: October 27, 2016 DUE DATE: November 07, 2016 COMMENT: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Sheet 1, Lot 10 building information does not match what is shown on sheet 10 or 11. 2. Revision letter states that "SHEET 13 OF 21 - Building information updated for Lot 10". Sheet 13 does not show lot 13, clarify. Once this comment is addressed Zoning will provide an over-the-counter review. Call or email to schedule an appointment for this review. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 10/27/2016 | SSHIELD1 | H/C SITE | REVIEW | Approved | |
| 10/27/2016 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 11/02/2016 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 11/07/2016 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. An approved development plan is not to be used for construction or modification of on-site utilities (e.g. water service to buildings, building sewers, site lighting, electrical service to buildings, etc.). The construction of the on-site utilities may be included with the permit for constructing a building or as a separate permit. 2. A separate permit is required for the installation of a private sewer collection system. Reference Title 18, R18-9-E302, 4.02 General Permit, Arizona Administrative Code. 3. Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole in the public sewer or private sewer collection system, provide a note stating that a backwater valve shall be installed in the building drain or branch of the building drain serving that floor (e.g. see buildings 11, 13, and 14). Floors discharging from above that reference point shall not discharge through the backwater valve. Reference: Section 715.1, IPC 2012, as amended by the City of Tucson. 4. On sheet 11, proposed manhole #8 is labeled as manhole #6. |
| 11/07/2016 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 11/09/2016 | AHINES2 | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) All approved documents submitted previously 3) All items requested by review staff 4) All items needed to approve these plans |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/15/2016 | KROBLES1 | OUT TO CUSTOMER | Completed |