| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/08/2015 | SPOWELL1 | START | PLANS SUBMITTED | Completed | |
| 04/08/2015 | RONALD BROWN | ADA | REVIEW | Passed | |
| 04/13/2015 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | FROM: Steve Shields Lead Planner PROJECT: Wilmot Plaza Development Package (Revision 1) DP14-0143 TRANSMITTAL DATE: April 13, 2015 DUE DATE: April 22, 2015 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 2-06.4.9.H.5 - If utilizing parking area access lanes (PAALs), they shall be designed in accordance with Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. 1) COMMENT: Provide a PAAL width dimension form the proposed loading space, shown east of Building 5, to the curbing to the east. 2-06.4.9.O - All applicable building setback lines, such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown. 2) COMMENT: Sheet 2 Building 5 height shows 30', Future Right of Way detail show a 24' street perimeter setback. With the shown 24' proposed setback the maximum building height would be 24'. 2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual. 3) COMMENT: Provide sidewalk width dimensions for the two (2) sidewalks that connect to the Broadway Blvd right-of-way sidewalk shown south of Building 5 If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov . |
| 04/13/2015 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Revise the size of the section of private sewer located directly west of building #1. Any fitting or connection in a drainage system that results in a reduction of the pipe area is prohibited. Reference: Section 706.2, IPC 2012. |
| 04/14/2015 | JASON GREEN | ENGINEERING | REVIEW | Reqs Change | DATE: April 14, 2015 DUE DATE: April 22, 2015 SUBJECT: Wilmot Plaza Development Plan Package- Revision 1 Engineering Review TO: Metro TED; Attn: Lisa Bowers LOCATION: 6301 E Broadway Blvd; T14S R15E Sec07 REVIEWERS: Jason Green, CFM ACTIVITY: DP14-0143 SUMMARY: Engineering Division of Planning & Development Services Department has received and reviewed the revised Development Plan Package. Engineering Division does not recommend approval of the Development Plan Package at this time. This review falls under the Unified Development Code (UDC), Administration Manual (AM) and Technical Standards Manual (TSM). Refer to the following link for further clarification: http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az The following items need to be addressed: SITE PLAN: 1) AM Sec.2-06.4.9.H.5.a: Revise the development plan package to provide a PAAL dimension from the new loading zone at the southeast corner of Building #5 to the curbing to the east. 2) AM Sec.2-06.4.9.N.3: Revise the development plan package to provide the minimum 4-foot wide dimension for the 2 sidewalks proposed from Building #5 to the right-of-way of Broadway Blvd. GENERAL COMMENTS: Please provide a revised Development Plan Package that addresses the comment provided above. For expedite purposes the development plan package can be reviewed over the counter (PDSD Engineering Division comment only) for stamp approval once all items have been addressed. Please call to schedule an appointment when ready. For any questions or to schedule meetings call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Planning & Development Services Department |
| 04/15/2015 | STEVE SHIELDS | ZONING-DECISION LETTER | REVIEW | Reqs Change | |
| 04/16/2015 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 04/21/2015 | PGEHLEN1 | COT NON-DSD | ENVIRONMENTAL SERVICES | Approved | The revisions to DP14-0143 have been reviewed on behalf of Environmental Services and are approved. If there are any questions, I can be reached at kperry@perryengineering.net From: Patricia Gehlen [Patricia.Gehlen@tucsonaz.gov] Sent: Friday, April 10, 2015 11:18 AM To: kperry@perryengineering.net Subject: DP14-0143/Wilmot Plaza Revision 1 Ken- Attached is the revision letter and plans for the above listed Dev Package Due date is 4/21/2015 Trish |
| 04/21/2015 | RONALD BROWN | HC SITE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/21/2015 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |