Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP14-0143
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/16/2014 | PGEHLEN1 | START | PLANS SUBMITTED | Completed | |
| 12/16/2014 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approved | |
| 12/16/2014 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Wilmot Plaza Development Package (3rd Review) DP14-0143 TRANSMITTAL DATE: November 6, 2014 DUE DATE: November 20, 2014 The Zoning Review Section conditionally approves the development package for this project subject to the following conditions. However, should there be any changes requested by other CDRC members, the Zoning Review Section conditional approval is void, and we request copies of the revised development package to verify that those changes do not affect any zoning requirements. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided. 2-06.4.8.B - All easements shall be drawn on the plan. The recordation information, location, width, and purpose of all easements on site will be stated. Blanket easements should be listed in the notes, together with recordation data and their proposed status. Should an easement not be in use and be proposed for vacation or have been abandoned, so indicate. However, should the easement be in conflict with any proposed building location, vacation of the easement shall occur prior to approval of plan unless written permission from easement holder(s) is provided. 1. COMMENT: A hold has been put on the certificate of occupancy for building permit T14CM07545 until the recordation information for the following easements has been provided on the development package. The "10' ELECTRICAL EASEMENT TO BE ABANDONED" that runs under Building 6 and the "EXISTING COMMUMICATIONS EASEMENT" that runs under Building 1, will need to be abandoned prior to approval of the development package. Provide the recordation information on the plan. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov . |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/06/2015 | CPIERCE1 | OUT TO CUSTOMER | Completed |