Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP14-0143
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/05/2014 | AROMERO4 | START | PLANS SUBMITTED | Completed | |
| 11/06/2014 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: Wilmot Plaza Development Package (3rd Review) DP14-0143 TRANSMITTAL DATE: November 6, 2014 DUE DATE: November 20, 2014 The Zoning Review Section conditionally approves the development package for this project subject to the following conditions. However, should there be any changes requested by other CDRC members, the Zoning Review Section conditional approval is void, and we request copies of the revised development package to verify that those changes do not affect any zoning requirements. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided. 2-06.4.8.B - All easements shall be drawn on the plan. The recordation information, location, width, and purpose of all easements on site will be stated. Blanket easements should be listed in the notes, together with recordation data and their proposed status. Should an easement not be in use and be proposed for vacation or have been abandoned, so indicate. However, should the easement be in conflict with any proposed building location, vacation of the easement shall occur prior to approval of plan unless written permission from easement holder(s) is provided. 1. COMMENT: A hold has been put on the certificate of occupancy for building permit T14CM07545 until the recordation information for the following easements has been provided on the development package. The "10' ELECTRICAL EASEMENT TO BE ABANDONED" that runs under Building 6 and the "EXISTING COMMUMICATIONS EASEMENT" that runs under Building 1, will need to be abandoned prior to approval of the development package. Provide the recordation information on the plan. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov . |
| 11/10/2014 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Approved | |
| 11/10/2014 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
| 11/14/2014 | RONALD BROWN | ZONING HC | REVIEW | Reqs Change | SHEET 3 1. Note 15 references DTL 200 (concrete sidewalk) to a ramp that is located at the SE corner of the front building and provides access to the Broadway Blvd. right of way. a. Provide a new note referencing the ramp to detail 8/9. 2. Note 36 references a railing to detail M/8 when it should be M/9. 3. Provide a new note referencing the ramp between the new and existing buildings to detail 7/9. 4. Reference comment 3 for ramp between two existing buildings to detail 3/4. Provide ramp width dimensions. 5. Insure all ramps have large scale details and are referenced to the proper details. 6. Insure that proper dimensions are provided at all large scale details. SHEET 4 7. Provide a large scale detail for the steps handrail shown in detail 3/4. END OF REVIEW |
| 11/19/2014 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Reqs Change | This review has been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) A disk containing all items submitted 3) All items requested by review staff 4) All items needed to approve this plan |
| 11/19/2014 | PGEHLEN1 | COT NON-DSD | ENVIRONMENTAL SERVICES | Reqs Change | The Development Plan has been reviewed on behalf of Environmental Services and the following will need to be addressed on the resubmittal: 1. It is acknowledged that the NW egress point is now one way, exit only, however it is not clear the service vehicle can maneuver this exit and turn north while staying within the adjacent travel lane on Wilmot. As previously requested, show the turning maneuvers per the turning templates in TSM Section 8 on the plans. 2. The detail for the enclosure calls out the rebar reinforcement for the enclosure slab but not for the apron. Add the call out for the apron concrete reinforcement. If there are any questions, I can be contacted at kperry@perryengineering.net |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/09/2014 | CPIERCE1 | REJECT SHELF | Completed |