Review Date Reviewer's Name Type of Review Description Status Comments
05/07/2015 AROMERO4 START PLANS SUBMITTED Completed
05/07/2015 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved Conditions of approval reviewed and approved by Patricia
05/12/2015 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: DP14-0064
5601 E. Broadway Blvd.
Development Package for Broadway Festival

TRANSMITTAL DATE: May 12, 2015

DUE DATE: May 20, 2015

COMMENTS: Zoning conditionally approves the DP with the following comments addressed and changes made on the final plan sheets for CDRC Manager Signature.

01. Follow up to the previous comment: The short term bicycle facility for building one does not appear to be within fifty feet of the public entrance. Relocate the facility to meet the required fifty foot distance and label the actual distance.

Previous Comment 3. Follow up to previous comment 16: Address the following comments related to the bicycle parking.

Each building must be provided with two (2) long term bicycle parking facilities.

Draw and label the main entrance to the buildings 2 and three. Label the distance from the short term bicycle parking facilities to the main entrance of all buildings. The maximum distance is 50 feet.
*********************************************************************

02. Rezoning condition 13 requires construction of a six foot high masonry wall along the full length of the north boundary and along the east boundary north of the access entrance. The DP site plan was corrected to indicate the wall as required by the rezoning condition. The landscape plan must also be revised as required to show a six foot high wall along the east boundary as described by the rezoning condition 13.
2-06.4.9.U - Indicate graphically, where possible, compliance with conditions of rezoning.
The following comments are related to some of the rezoning conditions.

a. Per rezoning condition 13, a 6 foot high masonry wall must be provided along the entire north frontage and along the east perimeter from the Leonora Av. access drive to the north. The plans indicate a stepped wall which is contrary to the rezoning condition. Revise the plans as per the rezoning condition.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package site plan and any requested documents.
05/14/2015 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Approv-Cond PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT
DP-14-0064 Broadway - Festival

() Tentative Plat
(X) Development Plan
(X) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other - Elevations

CROSS REFERENCE: C9-14-03 Ina Group - Broadway

NEIGHBORHOOD PLAN: Sewell-Hudlow Neighborhood Plan and Plan Tucson

GATEWAY/SCENIC ROUTE: YES

COMMENTS DUE BY: May 20, 2015

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies with Plan Policies
(X) See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(X) If DP is revised to be in compliance with "Conditional Approval criteria," then No Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan

Reviewer: msp
DATE: 05/7/15
Planning and Development Services Department
Community Planning Section
DP14 0064 - Broadway/Festival
May 7, 2015

Based on the applicant's request a concurrent review is under way for Development Plan DP14-0064, a retail/restaurant project and Rezoning Case C9-14-03, Ina Group-Broadway, to change the land use zone from C-1 and R-3 to C-1, to allow the site to be redeveloped for retail and restaurant land use with drive-through lane(s).

Development Plan DP14-0064 must comply with rezoning case C9-14-03, which was authorized by Mayor and Council on August 5, 2014.


Community Planning staff offers the following comment:

As per the August 5, 2014, Mayor and Council public hearing held on August 5, 2014, rezoning case C9-14-03 was authorized with conditions. Community planning staff gives a Conditional Approval to this project, subject to the following revision and criteria, as outlined below:

Development plan DP 14-0064 shall be revised as following:

1. Development plan DP14-0064 shall be revised to be in compliance with rezoning condition #13, which reads as following:
" A six (6') foot tall masonry wall with no less than six (6) inch wide masonry block material shall be located as part of the landscape buffer along the full length of the north perimeter adjacent to 10th Street, and that portion of the east perimeter landscape buffer located north of the Leonora Avenue access entrance.

Although revised, development plan, Sheet C.3, dated 4.23.2015 still indicates a the masonry wall with a drop down height from 6 feet to 4 feet, and with a final height of 2 feet along Leonora Avenue north of the access entrance into the rezoning site. Please correct to show six feet in height for the entire length of wall, as required per rezoning condition # 13.
05/14/2015 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. The revised development plan shows a private sewer collection system serving the three buildings on site and then discharging to public manhole PCWMD 8935-01. The rim elevation of this manhole is more than 12" below the floor elevations of the three buildings so a backwater valve will not be allowed. Reference: Section 715.1, IPC 2012, as amended by the City of Tucson.

2. If the private sewer collection system from the three buildings has a discharge rate of 3,000 gallons per day or greater, Pima County Department of Environmental Quality will have to review the design and provide an approval to construct the private sewer collection system. For a daily discharge rate of less than 3,000 gallons per day, the City of Tucson will review the plans for the private sewer collection system under a separate permit.
05/18/2015 ANDREW CONNOR LANDSCAPE REVIEW Approved
05/19/2015 JANE DUARTE COT NON-DSD PARKS & RECREATION Approved No proposed or existing Tucson Parks and Recreation facilities are affected by this development.

Howard B. Dutt, RLA
Landscape Architect
Tucson Parks & Recreation
(520) 837-8040
Howard.Dutt@tucsonaz.gov

>>> DSD_CDRC 5/7/2015 9:02 AM >>>

Dear Reviewers: This is an electronic distribution for a CDRC Tentative Plat review. If you normally receive paper copies of the review documents, you will receive them soon. The applicable case numbers are: CDRC Development Plan: DP14-0064
Existing and Proposed Zoning:
Proposed Use: Retail/Food Service
Due Date: 5/20/2015 ***Expedited Review***
05/21/2015 LOREN MAKUS ENGINEERING REVIEW Approved
05/21/2015 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:

1) Two rolled sets of the plans
2) A disk containing all items submitted
3) All items requested by reveiw staff
4) All items needed to approve these plans
05/21/2015 RONALD BROWN ZONING HC REVIEW Approved
05/21/2015 PGEHLEN1 COT NON-DSD ENVIRONMENTAL SERVICES Reqs Change The Development Package has been reviewed on behalf of Environmental Services Dept. and the following will need to be addressed on the resubmittal:
1. The added detail for the combination of the two single enclosures references the detail for the double enclosure. The footings for both enclosures called out in Detail 5 of Sheet C.2 is not correct per Figure 2 of TSM Section 8. The footing should be 1.0 ft thick x 1 ft. – 8 inches wide and the concrete shall be 3,000 psi. The concrete base for the bollards shall be 3 ft. deep. Also, add to the enclosure details that the Type B metal Deck for the gates is to be at least 1/8 inch thick per Figures 3A and 3B.
If there are any questions, I can be reached at kperry@perryengineering.net
06/04/2015 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approv-Cond As per Outdoor Lighting notes on plan sheets 'C3' and 'C4', all outdoor lighting shall be permitted under a seperate permit and shall comply with the Tucson Outdoor Lighting Code.

Pending futher discussion with Electrical reviewer