Permit Number: DP13-0236
Parcel: 13316020P

Address:
6501 E GRANT RD

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP13-0236
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/03/2014 MARTIN BROWN COT NON-DSD FIRE Approved
06/05/2014 CPIERCE1 START PLANS SUBMITTED Completed
06/11/2014 PGEHLEN1 COT NON-DSD ENVIRONMENTAL SERVICES Approved The Development Plan for DP13-0236 has been reviewed on behalf of ESD and is approved. If you have any questions, I can be contacted at kperry@perryengineering.net
06/11/2014 LAITH ALSHAMI ENGINEERING REVIEW Approved Laith Alshami, Engineering and Floodplain Review, 06/11/2014,

SUBJECT: Insite @ 6501 E Grant Road
DP13-0236, T14S, R15E, SECTION 06

RECEIVED: Development Plan Package on June 03, 2014

The subject project has been reviewed. The Development Package is acceptable and it is hereby recommended for approval pertaining to Engineering and Floodplain Review.

If you have any questions, I can be reached at 837-4933 or Laith.Alshami@tucsonaz.gov
06/11/2014 PGEHLEN1 PIMA COUNTY PIMA COUNTY - REGIONAL FLOOD CTRL DIST Approved We have no further comments.
06/12/2014 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Approv-Cond PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

DP13-0236 InSite - 6501 E. Grant Road

() Tentative Plat
(X) Development Plan
(X) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other - Elevations

CROSS REFERENCE: C9-13-14 - InSite/Grant Road

NEIGHBORHOOD PLAN: Plan Tucson

GATEWAY/SCENIC ROUTE: NO

COMMENTS DUE BY: June 12, 2014

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies with Plan Policies
(X) See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(X) Resubmittal Required:
() Tentative Plat
(X) Development Plan
(X) Landscape Plan
(X) Other - CONDITIONALLY APPROVED, PENDING MINOR CORRECTIONS.

REVIEWER: msp
DATE: 06/12/2014
Planning and Development Services Department
Community Planning Section
DP13 0236 - InSite - Grant Road
June 12, 2014

Based on the applicant's request; a concurrent review is under way for Development Plan 13-0236, and Rezoning Case C9-13-14 InSite/GrantRoad, to change the land use zone from RX-2 residential to C-1 commercial zone, to allow the redevelopment of three parcels as one site to permit new building, required parking, and retail/restaurant land uses.

Currently the development plan has a CONDITIONAL approval pending minor corrections of the following items. Development plan DP13-0236; is subject to rezoning case C9-13-14, conditions of rezoning as approved on April 23, 2014by Mayor and Council.

Applicant to correct the following minor corrections. DP will require another resubmittal prior to the removal of the CONDITIONAL approval. The following are the minor corrections needed.

1. Prior to development plan approval, correct rezoning conditions (general notes) on C9-13-14, to read verbatim, as approved by Mayor and Council.

2. Prior to development plan approval, provide full size four-sided building elevations as supplemental building elevations to the development plan package. Building elevations to be in substantial compliance with the preliminary development package dated March 21, 2014, which includes color building elevations. Rezoning condition #12 also states building elevations shall display varying materials along all four sides of the proposed building.

3. Prior to development plan resubmittal, the proposed development plan, dumpster masonry wall enclosure elevations are not in compliance with rezoning C9-13-14, condition # 10, which states the six foot tall masonry wall shall be constructed of textured concrete block, and painted with a contrasting color band matching that of the principle building. Please provide color dumpster enclosure, four sided elevations to be in compliance rezoning condition # 10. If in a "detail," provide Key Notes.
06/16/2014 DAVID RIVERA ZONING REVIEW Approv-Cond FROM: David Rivera
Principal Planner

PROJECT: DP13-0236
6501 E Grant Road
Development Package - Retail/Food Service Multi-Tenant Development
Rezoning Case Number C9-13-14 RX-2 to C-1 Concurrent Review

TRANSMITTAL DATE: June 16, 2014

DUE DATE: June 30, 2014

COMMENTS: Please resubmit the final revised DP drawings along with a response letter, which states how the final remaining Zoning Review Section comments were addressed.


***Jeff, I did my review based on the set of plans you left with me that included the changes made based on Manny Padilla's comments. The following comment is the only item left for full zoning approval. At this time I am granting a conditional Zoning approval pending the change being made to the final copy for the CDRC manager's signature.

Per your response to the previous follow-up comment, the distance from the patio area to the property line was to have been labeled. The distance to the north property boundary from the patio area could not be verified on the plan. Add the proposed distance. (The zoning of the WASH is RX-2.)

.14 Follow-up to previous comment 31: The following comments are related specifically to the rezoning conditions dated 4/13/14.

Condition 9: Your response to condition 9 states that the patio area is to be a minimum of 50 feet from the north property boundary. There is no dimension indicating the distance from the property boundary. Based on the scale of the drawing it appears that the distance from the fenced patio area is

Comment 2: Under the General Notes on sheet one, include the use specific standards for the Food Service Use with Alcoholic Beverage Service as a secondary use. The following section numbers were not listed under general note 3. The note shall include .3 & .5 through .9

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package site plan and any requested documents
06/17/2014 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change

Final Status

Task End Date Reviewer's Name Type of Review Description
06/17/2014 PGEHLEN1 APPROVAL SHELF Completed
06/17/2014 PGEHLEN1 OUT TO CUSTOMER Completed
06/17/2014 PGEHLEN1 REJECT SHELF Completed